QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 14,001–14,100 of 14,770
Durairaj, E., Rajbongshi, J., & Vincent, M. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016368
Wang, K., Su, Y., Dai, Y., Shen, G., Chen, Y., Feng, Q., Lin, X., & Xue, D. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-14003-0
“The methodological quality of the included studies was independently assessed by two reviewers using the QUA-DAS-2 tool [19].”
Polašek, O. (2026) · Research Square · doi:10.21203/rs.3.rs-10305898/v1
Efficacy and Safety of Dupilumab in Eosinophilic Esophagitis: A Systematic Review and Meta-Analysis
Khalaf, R., That, A. T., Tardio, N., Afif, W., Schneider, R. E., & Ben‐Shoshan, M. (2026) · International Archives of Allergy and Immunology · doi:10.1159/000553602
Sha’ari, A. B. M., Arafat, H. M., Din, T. A. D. A. T., Yusoff, B. M., Shamallakh, O. M., & Rahman, W. F. W. A. (2026) · Journal of the Egyptian National Cancer Institute · doi:10.1186/s43046-026-00383-6
“All studies were conducted in symptomatic, referred, biopsy-enriched, or cancer-enriched populations rather than true consecutive screening cohorts, meaning that performance figures cannot be generalised to the community screening settings for which Braster LCT is primarily intended [22].”
InfluentialDavis, S. (2026) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Farhan, M., Venkatesan, S., Amine, A., Almashhadani, R. Z., Aljumaa, M., Karam, B. A., Hakim, L., Hasan, J. A. A., Zoreik, S., Alkhazali, A., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-10368659/v1
Gupta, N., Purohit, P., Sood, S., & Rana, A. (2026) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002209
Hernández, N. A. M., Flores-Sánchez, R. C., Leines-Castelán, D., Buenabad-Hernández, A. E., Ortega-Caramillo, C., Díaz-Rosas, G., la Selva, V. D. L.-D., Leyva-Rosas, V. H., Islas-Olvera, N. J., Chamorro-Juárez, P. P., et al. (2026) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2026.501860
Methods for defining equity-stratifying variables: a systematic review of validation studies
Osman, H., Hecker, T., Hossain, Z., Li, H., Landsberg, A., Ackroyd, A., Ravani, P., Donald, M., James, M. T., Pannu, N., et al. (2026) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2026.112420
Shi, J., Xiao, F., Liao, J., Wei, Y., Lei, L., Zhou, Z., Han, X., Wu, H., Ye, R., Yuan, Z., et al. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113078
Sarma, I. D., Nath, C., Ahmed, K. A., Rajkhowa, P., Biswas, K. P., & Saikia, D. (2026) · Cureus · doi:10.7759/cureus.112820
“The figure was generated using the QUADAS-2 tool [13].”
InfluentialAltawil, F. M., Korayem, M. A., AlHazmi, H. I., & Mahmoud, M. M. (2026) · Research Square · doi:10.21203/rs.3.rs-10371123/v1
Stanoiu, A.-M., Huțanu, D., Șorop-Florea, M., Alexandru, A., Varga, N.-I., Bagiu, I. C., Popa, M.-D., Hîrtie, B., Balica, N. C., Mot, C. I., et al. (2026) · Medicina · doi:10.3390/medicina62071372 · Cited by 1
Localized surface plasmon resonance-based point-of-care testing for pediatric sepsis
Zhang, X. D., Zhang, J., Wang, M. M., Liu, Z., Gai, Z., & Li, X. (2026) · Frontiers in Pediatrics · doi:10.3389/fped.2026.1880296
Calastra, C. G., Barna, R.-A.-M., Orellana, F., Abendaño, A. A., Baffelli, S., Aiyangar, A. K., & Parrilli, A. (2026) · Clinical Imaging · doi:10.1016/j.clinimag.2026.110905
Sangle, S. (2026) · International Conference on Innovations in Cybersecurity and Data Science (ICICDS) · doi:10.1109/icicds70526.2026.11604955
Pudendal Nerve Entrapment Within Alcock’s Canal as a Compartment-Like Syndrome: A Systematic Review
Okoye, J., Mohammed, M. I. H., Subhedar, D., Mohamed, M. I. A., Shetty, S., & Ali, R. (2026) · Cureus · doi:10.7759/cureus.112846
“Diagnostic accuracy studies involving imaging modalities or electrophysiological investigations were assessed using the QUADAS-2 tool [14].”
Espino, P. H., Couper, R. G., Burneo, J. G., Debicki, D., Ganesan, S. L., & Gofton, T. E. (2026) · Epileptic Disorders · doi:10.1002/epd2.70338
Andrevna, A., & Juel, D. (2026) · International Journal of Artificial Intelligence Engineering and Transformation · doi:10.54660/ijaiet.2026.7.2.14-24
Antonow, M., & Siemiński, M. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27146432
Neto, O. S., de Jesus, M. S., de Oliveira, D. Q., Imoto, A. M., & Amorim, F. F. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-119561
“The certainty of the evidence will be assessed according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach, 25 which considers five domains: risk of bias, imprecision, inconsistency, indirectness and publication bias.”
Damen, J. A., Hoogendam, J. P., Idema, D. L., Lokerse, M. E., Heus, P., Jenniskens, K., Kamm, I. M. L. P., Traets, M. J. M., Spijker, R., Zweemer, R. P., et al. (2026) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2026.115330
Saleh, M., Hegazy, M., Alsaied, M. A., Elkenani, A. J., Ehab, R., Hesham, M., Razek, H. M. A. E., Nazemi, S., Shalaby, M., & El‐Hussuna, A. (2026) · medRxiv · doi:10.64898/2026.07.17.26358357
Desai, S. P., Hori, Y. S., Lam, F. C., Zagzoog, N., Kalra, N., Tayag, A. T., Ustrzynski, L., Emrich, S. C., Gu, X., Park, D. J., et al. (2026) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2026.112210
Carvente, C. T., de Toledo, C. F., & de Toledo, C. F. (2026) · Arquivos de Gastroenterologia · doi:10.1590/s0004-2803.24612025-099
“However, morbidity associated with the procedure remains significant, including risks of postoperative pancreatic fistula, gastroparesis, and pancreatogenic diabetes, requiring careful assessment of the risk–benefit balance, particularly in elderly or frail patients (1,17,22,30,33) .”
InfluentialRho, J. S., Kang, S. G., Kim, S., & Song, S.-W. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15145649
TIOTSOP, M., Roger, D. O., Panta, U. R., Asnake, Z. T., Ismail, Z., & Salabei, J. K. (2026) · Clinical Imaging · doi:10.1016/j.clinimag.2026.110906
Fang, S.-S., & Chen, S.-H. (2026) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-026-01820-1
“…quality of included diagnostic accuracy studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool [22], which evaluates risk of bias and applicability concerns across four domains: patient selection, index test, reference standard, and flow and…”
Morărașu, Ș., Luncă, S., Ceobanu, A. N., Braniste, A., & Dimofte, G. M. (2026) · Life · doi:10.3390/life16071205 · Cited by 1
“Methodological quality and risk of bias were assessed using an adapted Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) framework [29] (Figure 2, Supplementary Table S2).”
Chen, R., Wen, Z., Cheng, C., Li, X., Wang, J., Hong, L., & Chen, H. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1871968
Soares, R. B. D. M., BOTAN, R. D. N., & Kessler, I. M. (2026) · CVIR Endovascular · doi:10.1186/s42155-026-00731-6
“QUADAS-2 was used as the main risk-of-bias framework [8], with QUADAS-C concepts applied to comparative diagnostic accuracy issues where CEUS and CTA were evaluated in the same clinical pathway [9].”
Applications of quantum AI in brain disorder diagnosis: A systematic review
Jafari, M., Tang, Z., Acharya, U. R., & Li, Y. (2026) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2026.109565 · Cited by 1
Taye, B., Pareyn, M., Getu, E., & Berens‐Riha, N. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-14035-6
“Every domain was evaluated for bias risk and, for the first three domains, concerns regarding applicability [34].”
Draxl, E., Ochodo, E., Pillay, P., & Ndlovu, N. (2026) · Frontiers in Parasitology · doi:10.3389/fpara.2026.1830789 · Cited by 1
Ambarsari, C. G., David, N. I., Kim, D., Piccinini, A. M., Taal, M. W., & Kim, J. J. (2026) · Transplantation · doi:10.1097/tp.0000000000005880
Xu, R., & Jiang, L. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1811135
Alalwy, A., Alshreef, B., Semoud, I., Ahmed, B., Alyousfi, S. A., Sayed, M. M., Alshammari, T. R., Alasslani, T. A., Alanazi, A. F., Alaufi, S. A., et al. (2026) · Cureus · doi:10.7759/cureus.113198
“For diagnostic accuracy outcomes, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was used to evaluate bias across four domains: patient selection, index test, reference standard, and flow and timing [12].”
AI-integrated pulmonary nodule assessment: a systematic review and meta-analysis
Choonara, L., Vally, M., Molla, S. R., Boukrout, M., Ismail, Q., Mahomed, A., & Naidoo, V. A. (2026) · Medical Research Journal · doi:10.5603/mrj.112812
Safar, I. E. M., Díaz, J. P. D. L. O., D., D. A. M., Garavito, C. R., Villegas, F. D. J. S., F., M. P. D., Barrios, M. I. H., & Villamarín-Velásquez, R. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113219
Ultrasound assessment of abdominal respiratory muscles during ventilator weaning: A scoping review
Parada-Gereda, H. M., Patiño, L. A., Peña-López, L. A., Muñoz, D., & Molano-Franco, D. (2026) · Canadian Journal of Respiratory Therapy · doi:10.29390/001c.165137
Phurijaruyangkun, S., Tangjitrungrot, P., Pongparit, S., Wattanakul, N., Jantrapanukorn, B., Veeramano, R., Augkarawaritsawong, S., Kumkrong, K., Sirothot, T., Jaratsing, P., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27156575 · Cited by 1
“While this sample size is adequate for preliminary evaluation, it may not fully capture the variability encountered in real-world clinical settings [16,17].”
Rojas-Pirela, M., Andrade-Alviárez, D., Rojas, V., Castillo, C., Prieto-Rojas, A., Rueda-Cala, V., Carbonell, C., Salete-Granado, D., Pérez, C., Pérez-Nieto, M. Á., et al. (2026) · Parasites & Vectors · doi:10.1186/s13071-026-07581-0
“Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [42, 43], adapted to the exploratory and heterogeneous nature of the included miRNA expression studies by considering sample characterization, analytical methodology, and validation…”
Shaiban, A. S., Alobaid, M. A., Alqahtani, O. S., Alroomy, R., Jabali, A. H., Almnea, R. A., Alaajam, W. H., Mehta, V., & Moaleem, M. M. A. (2026) · International Dental Journal · doi:10.1016/j.identj.2026.109758
“The QUADAS-2 tool consists of 4 domains.”
InfluentialMaes, M., Shrestha, S., Keith, D. A., Handa, S., Lee, Y., der Cruyssen, F. V., Verhelst, P.-J., Sillmann, Y. M., Jacobs, R., & Guastaldi, F. P. S. (2026) · Digital Dentistry Journal · doi:10.1016/j.ddj.2026.100106 · Cited by 1
Millán-Alanís, J. M., Torres, L. A. G., Jáquez-Quintana, J. O., Sáenz, L. M., Aldaco, A. C. G., & Maldonado-Garza, H. J. (2026) · Pancreatology · doi:10.1016/j.pan.2026.07.011
Review, P. J. O. M. &. C. (2026) · Pakistan Journal of Medical & Cardiological Review · doi:10.5281/zenodo.21512430
Kaur, B., Gill, G. S., Kaur, K., Chaudhary, A., & Garg, A. (2026) · Cureus · doi:10.7759/cureus.113226
Reynoso, F. D. P., Suárez, P. A. N., Rivera, H. A. H., Soto-Cajiga, J. A., & Sánchez-Saquín, C. H. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111110
Vilaltella, M., Serés‐Noriega, T., Cid-Bertomeu, P., & Huerva, V. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15155792
Teleaudiology for Hearing Assessments
CDA-AMC (2026) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2026.1483
Telecan, T., Capraș, R.-D., Poenar, S. T., Sevan-Libotean, R., Gaia‐Oltean, A. I., Crivii, C. B., & Badea, A. F. (2026) · Bioengineering · doi:10.3390/bioengineering13080855
Tran, T. H., Hien, N. T. T., & Tran, T. H. (2026) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2026-004244
Pérez, A. D., & Yáñez, Z. (2026) · Research Square · doi:10.21203/rs.3.rs-10183117/v1
Schneider, C., Frei, N., Fernandez, A., Frei, C., Wahedi, K., Husarek, J., Karrer, T., Aubert, C. E., Lehmann, B., & Müller, M. (2026) · BMC Medicine · doi:10.1186/s12916-026-05094-2
“To assess methodological quality, we used an adapted AMSTAR 2 checklist [38] (see Additional file 1: Table S3 [39]).”
Yu, H., Kou, J., He, Q., Zhang, D., Chen, Y., & Liang, J. (2026) · BMC Gastroenterology · doi:10.1186/s12876-026-05164-y
A systematic review of the cross-cultural translation and adaptation of adaptive behaviour measures
McCabe, E., O’Donald, F., & Calia, C. (2026) · International Journal of Developmental Disabilities · doi:10.1080/20473869.2026.2690625
van Haaster, L. W. F., Tutal, E., Mekary, R. A., & Vleggeert-Lankamp, C. L. A. (2026) · Brain and Spine · doi:10.1016/j.bas.2026.106246
“Two researchers (LWFH and ET) independently screened the titles and abstracts of all retrieved records for eligibility, and disagreements were discussed with a third reviewer (CLAVL).”
Duran, J. C. M., Osorno-Castillo, K., & Díaz, G. M. (2026) · Technology in Cancer Research & Treatment · doi:10.1177/15330338261465062
Elassra, O. A. Y., Shetty, S., Hans, A., Ali, O., Ali, S. K. S., Khan, H., & Buch, M. H. (2026) · Cureus · doi:10.7759/cureus.113360
“The methodological quality of the included studies was assessed using the QUADAS 2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool for diagnostic accuracy studies and the SANRA (Scale for the Assessment of Narrative Review Articles) checklist for review-based articles [8,9].”
Clinical application of artificial intelligence in corneal transplantation
Rad, N. R. (2026) · Medical Hypothesis Discovery & Innovation in Optometry · doi:10.51329/mehdioptometry249
“…were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, which evaluates risk of bias across the domains of patient selection, index test, reference standard, and flow and timing, while also assessing applicability concerns for the first three domains [24].”
Systematic Review of AI ‐Driven Applications for Screening Nasopharyngeal Carcinoma Using MRI
Wong, L. M., Leung, H. S., Yang, Z., Tsang, Y. M., Chan, Y.-T., So, T. Y., King, A. D., & Ai, Q. Y. H. (2026) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.70445
“QUality Assessment of Diagnostic Accuracy Studies (QUADAS)- 2 tool [22] was used for evaluating the risk of bias of the reviewed studies, and signaling questions were designed based on the components in the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) checklist [23].”
Xie, B., & Wen, Q. (2026) · Metabolomics · doi:10.1007/s11306-026-02493-7 · Cited by 1
“Therefore, these studies were further subjected to a methodological quality assessment (risk of bias and appli - cability) by using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool (Whiting et al., 2011).”
Vaz, M. D., Debouche, S., Marsman, M., Lamperti, M., Antoniou, S. A., Schünemann, H. J., & Neumann, I. (2026) · European Journal of Anaesthesiology Intensive Care · doi:10.1097/ea9.0000000000000126
“35 We will also assess the certainty of the evidence following the GRADE approach.”
Low-Field and Portable MRI for Acute Ischemic Stroke: A Systematic Review
Borkar, R. R., Jeggari, S. D. R., Kandel, K., Partheepan, K., Sharma, N., & Nayak, S. S. (2026) · Brain Sciences · doi:10.3390/brainsci16080788
Dewaele, K., Jouego, C. G., Asim, A., Laenen, L., Meehan, C., & André, E. (2026) · Journal of Clinical Microbiology · doi:10.1128/jcm.00321-26
“Risk of bias was appraised per study using the QUADAS-2 protocol for evaluation of diagnostic studies (see File S2 and Table 2) (30).”
Li, S., Ye, C., Chen, L., Wu, Y., & Lu, G. (2026) · Annals of Intensive Care · doi:10.1016/j.aicoj.2026.100122
“Data extraction and risk-of-bias assessment were performed independently by two reviewers using standardized forms based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [26].”
Maharani, E., Dinarti, L. K., Anggrahini, D. W., Laila, A. H., Rozanti, N. M., & Yuniadi, Y. (2026) · Journal of Arrhythmia · doi:10.1002/joa3.70409
Gupta, B., Blanco, N., Wagle, C., Acharya, N., Takanche, J. S., Shrestha, R., Ludeman, E. M., Hazen, T. H., & Charurat, M. E. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-14121-9
“…to study design: the Joanna Briggs Institute (JBI) Critical Appraisal Checklists for observational studies, including cohort, cross-sectional, and case-series designs [22, 23] and QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) for studies with diagnostic accuracy components [24].”
Diao, M., Zhu, Y., & Tang, H. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1883944 · Cited by 1
“The methodological quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool (QUADAS-2) (17).”
InfluentialYu, H., Li, Y., Mo, G. P., Luo, Z., Zarbock, A., Fuhrman, D. Y., Kang, Y., Chen, D., Rimmelé, T., Prowle, J. R., et al. (2026) · Intensive Care Medicine · doi:10.1007/s00134-026-08549-5
“…STARD criteria) and the methodological quality according to the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies version 2) checklist [18]; b) to identify sources of heterogeneity; c) to summarize the diagnostic or prognostic performance of candidate biomarkers to inform their…”
Wong, C. S., Tryliskyy, Y., Rashid, R., Barman, S., Shuymeko, V., Sharma, A., & Hossain, M. (2026) · Journal of Transplantation · doi:10.1155/joot/3052963
Vo, B. T. N., Huynh, Y.-P., Tang, P. M., Chen, J., & Tam, K. (2026) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000008235
Ekici, E., Esen, D. H., Yüzbaşıoğlu, Ü., & Taş, S. (2026) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2026.07.037
Топузов, М. Э., Vodopyan, S. S., Atamas, M. M., & Абузарова, С. (2026) · Urology Horizons · doi:10.1016/j.urolhz.2026.100011
Itatani, N., & Zavaglia, M. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1771022
Lai, N. M., Yeo, K. T., Kong, J. Y., Duan, M., Lee, S. W. H., Chaiyakunapruk, N., Varshney, K., Ovelman, C., & Chen, K. (2026) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.70513
Chen, L., & Yang, Q. (2026) · Pakistan Journal of Medical Sciences · doi:10.12669/pjms.42.8.19637
Pardal-Refoyo, J. L., & Zapatero-Sanchez, I. (2026) · medRxiv · doi:10.64898/2026.07.25.26358934
Ghazanfar, Z., Fatima, A., Ali, S. G., & Jung, Y. (2026) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-026-07130-6 · Cited by 1
“Study quality and clinical readiness were evaluated using a framework adapted from: • FDA AI/ML SaMD guidance [30] • CONSORT-AI [31] • CLAIM [32] • QUADAS-2 [33] • PROBAST [34] Due to the heterogeneity of study designs, no single tool was applied in its original form.”
Fitchett, E. J. A., Ndoye, A. M., Bailey, R. L., Barry, A., Dia, N., Dramé, N. D., Diallo, O. N., Dieng, I., Faye, J., Kabo, K., et al. (2026) · doi:10.12688/verixiv.3554.1
Exploring Bias in Medical Applications of Large Language Models: Protocol for a Systematic Review
Rao, S. G., Boutrous, C., Kormilitzin, A., Tai, X. Y., Hotchkiss, L., Cong, C., Meinert, E., Liang, H., Dong, H., & Harrison, J. R. (2026) · JMIR Research Protocols · doi:10.2196/91348 · Cited by 1
Novotny, J. S., Thatcher, A. L., Shatti, D., Mofardin, S., Rakuša, M., Kolenc, M., Zupan, M., Frol, S., Popović, K. Š., Oblak, J. P., et al. (2026) · Journal of Alzheimer s Disease · doi:10.1177/13872877261471428
“43 – 45 48 Accordingly, the reported estimates likely represent an upper bound of ACE-R performance and should be interpreted cautiously in broader setting.”
da Silva, I. C., Holanda, D. D. R. A. R., Carvalho, C. G. M., Souza, L. R., da Silva, V. M., Moreira, R. P., Lopes, M. V. D. O., & Lira, A. L. B. D. C. (2026) · International Journal of Nursing Knowledge · doi:10.1177/20473087261471628
Patel, S., Nischal, S. A., Ceccon, L., Nallanukala, G. S., Kale, K. M., Sarikonda, A., Serva, S. N., Jallo, J., Harrop, J. S., & Prasad, S. K. (2026) · Acta Neurochirurgica · doi:10.1007/s00701-026-06984-3 · Cited by 1
“Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [71], evaluating patient selection, index test conduct, reference standards, and flow or timing.”
Gyedu, E. J., Jenkins, S., Lane, D., Akram, A., Salim, F., Ng, L. L., Jones, D. J. L., Bernieh, D., & Gupta, P. (2026) · Journal of Human Hypertension · doi:10.1038/s41371-026-01186-x
“Due to the different units of measurement reported by the included studies on peptide levels, all the units were converted into fmol/mL.”
HyperTransUrban: a vision transformer-driven survey of change detection using hyperspectral imaging
Mittal, P., Sharma, B., Yadav, D. P., & Liatsis, P. (2026) · Artificial Intelligence Review · doi:10.1007/s10462-026-11655-x
Development of a tool to assess the risk of bias in statistical simulation studies: study protocol
Arnup, S. J., Turner, S., Page, M. J., Korevaar, E., McDonald, S. J., Higgins, J. P. T., & McKenzie, J. E. (2026) · F1000Research · doi:10.12688/f1000research.184100.1
Dahlgaard, N. B., Tong, Y., Shitara, K., Fassan, M., Mau‐Sørensen, M., & Egebjerg, K. (2026) · ESMO Gastrointestinal Oncology · doi:10.1016/j.esmogo.2026.100369 · Cited by 1
“18,20,27 When reported separately, liver metastases showed variable patterns of CLDN18.”
Allaham, S. M. I. (2026) · Dementia and Neurocognitive Disorders · doi:10.12779/dnd.2026.25.3.141
“4,5,11,13 In addition, few studies reported prospective clinical impact, cost-effectiveness, or integration with other biomarkers such as positron emission tomography (PET) or cerebrospinal fluid measures, despite emerging frameworks that conceptualize AD as a biological rather than purely clinical…”
Pasecinic, V., Novacescu, D., Zară, F., Dumitru, C. Ș., Armega-Anghelescu, A., Latcu, S. C., Cumpănaş, A. A., Căprariu, R., Banov, P., Stana, A. H., et al. (2026) · Biomedicines · doi:10.3390/biomedicines14081736
Sripodok, P., Panutyotin, N., Liampeng, S., Thadanipon, K., Thakkinstian, A., & Kosanwat, T. (2026) · BMC Oral Health · doi:10.1186/s12903-026-09464-3
“The methodological quality of included studies was assessed independently by two reviewers (PS and TK) using QUADAS-2 [23] or QUADAS-C [24], with disagreements resolved by consensus.”
Alzahrani, R. A. J., Alhithlool, A. W., Alsudais, A. S., Alharbi, A., Alyousif, S. F., Almutairi, M. N., Alharbi, K. S., Almalki, A. M. A., Alshehri, B. A., Alkhawajah, A. A., et al. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15155976
de Lima, T. M. N. R., Bezerra, P. M. M., dos Santos, F. G., Serpa, E. B. D. M., Valença, A. M. G., & de Sousa, S. A. (2026) · Brazilian Oral Research · doi:10.1590/1807-3107bor-2026.vol40.044
Lopes, O. M. S., Oliveira, J. A., Nogueira, V. B. A., Ribeiro, L. F., Zamae, M. I. S., Vieira, M. F. G. O., Pimenta, V. M. D. E., & Reis, Z. S. N. (2026) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-026-06519-4
“QUADAS-2 judgments take into consideration specific recruitment methods, blinding procedures, full reporting of exclusions, among others (Whiting et al. 2011 ).”
Mehdikhani, B., Damavand, R. S., Zolfi, E., Narimani, N., Atarod, M. M., Maleki, H., Farshid, S., Negahi, A., Aghili, K., & Neámatzadeh, H. (2026) · Research Square · doi:10.21203/rs.3.rs-10022523/v1
Silva, R. R. A. D. S., Batista, P. K. A., Montenegro, M. V., Gaelzer, G. C., de Lucena, L. A., Molinari, M. E., de Oliveira, J. P., Huntermann, R., Malik, M., Dandamudi, M., et al. (2026) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2026.115349
Hatimah, H., Sugianto, I., Yunus, B., Hidayat, M. F., & Nurrahma, R. (2026) · Imaging Science in Dentistry · doi:10.5624/isd.20250335
Imperiale, T. F., Godfrey, M., Thomas, M. R., Sheel, V., & Hinrichs, R. (2026) · BMC Gastroenterology · doi:10.1186/s12876-026-05013-y
“…study objective intersects a standard clinical systematic review and a diagnostic test accuracy review, we used criteria and guidelines from the Cochrane GRADE group and modified the QUADAS-2 criteria to create a tool to assess methodological quality specific for this review’s objectives [9].”
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.