QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 14,301–14,400 of 14,770
Podocalyxin as biomarker for early detection of preeclampsia: A systematic review and meta-analysis
Biadgo, B., Zenaw, A., Worede, A., & Fetene, G. (2026) · Pregnancy Hypertension · doi:10.1016/j.preghy.2026.101523
Nazareth, K. R., Jamileh, E., Muhammad, F., Farooq, O., Sequeira, A., Awais, A., & Antoun, I. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag143
Mens, J., Masthoff, E., Heus, P., & Bogaerts, S. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1908178
“Quality was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool, Second Edition (QUADAS-2; Whiting et al., 2011), which the Cochrane Collaboration recommends for appraising prognostic and diagnostic accuracy studies (Reitsma et al., 2023).”
Sachdeva, A., Kumar, Y. P., Chawla, A., Kumar, V., Sharma, S., Upadhyay, A. D., Ballal, D. V., & Logani, A. (2026) · Caries Research · doi:10.1159/cre/abuag008
Srour, A., Mor, A. G., Omar, M., Barash, Y., Litmanovich, D., Srour-Asmar, M., Klang, E., & Gorenshtein, A. (2026) · Research Square · doi:10.21203/rs.3.rs-10950882/v1
Jiang, J., & Zhang, S. (2026) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2026.112329
Elhassan, L. A., Ali, M. A. M., Yousif, E., Eid, M. A. E. A., Ahmed, H. E. A., Hamid, N. F. F. M. A., Atroun, A. F. H., Mohamed, M. M. I., & Osman, H. M. M. (2026) · Cureus · doi:10.7759/cureus.115927
“Methodological quality and applicability were appraised with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool across its four risk-of-bias domains [9].”
Dai, H., Ji, L., Gao, J., Zhang, H., Ge, S., & Yuan, C. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117654
Lee, H., Ha, S. Y., Kim, S., & Min, Y. W. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1953562
“Across 42 analytic scopes, QUADAS-2 overall judgments were high for 40 and unclear for 2, whereas all 42 PROBAST overall judgments were high; all 28 reports were high under the secondary report-level worst-domain rule for both tools (Table 2).”
Xie, Q., Yang, Z., Sun, Y., Zhao, N., Hou, R., Di, Z., & Ma, J. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1887134
Artificial intelligence-assisted endoscopic diagnosis of esophageal squamous cell carcinoma
Mao, J., Li, K., Qian, Z., Zhang, J., Gao, S., Tian, G., Yang, D., Tang, X., Yang, X., Li, C., et al. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1837887
Urso, D., Giannoni-Luza, S., Guidetti, M., Neri, F., D'Amico, L., Landolfo, S., Boluarte, A. N. S., Santoro, C., Volpe, G., Priori, A., et al. (2026) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2026.108982
Chinaliyeva, G., Chinaliyev, A., Туймебаевна, А. Ж., Salybekov, A. A., Shakirova, A., Khassenov, D., Burkitbayev, Z. K., & Dznelashvili, N. (2026) · Diagnostics · doi:10.3390/diagnostics16182902
Chen, J., Lee, T. H., Huang, Y., Ho, W.-Y., Chan, M., Wu, V., Hsiao, C.-C., & Chang, C. (2026) · Clinics · doi:10.1016/j.clinsp.2026.101098
Makukhina, T. B., Penzhoyan, G. A., Dontsova, M. V., & Сергеевич, Щ. П. (2026) · Obstetrics and gynecology News Opinions Training · doi:10.33029/2303-9698-2026-14-2-64-78
Artificial Intelligence-Enabled Electrocardiograms and Pregnancy-Related Cardiomyopathy
Adesanya, O. A., Irorere, O. E., Young, K., Tobah, Y. B., Carter, R. E., & Adedinsewo, D. A. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.103180
Choudhary, A., Altınkaynak, Y., & Altinkaynak, B. A. (2026) · Research Square · doi:10.21203/rs.3.rs-10950437/v1
Zhu, J., Lin, H., Zhao, J.-W., & Yang, Z.-Y. (2026) · World Journal of Gastroenterology · doi:10.3748/wjg.123989
Cheng, P., Ma, X., & Mi, J. (2026) · Research Square · doi:10.21203/rs.3.rs-10621620/v1
Piassa, T. R., Silva, A. M. B. D., & Corona, L. P. (2026) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2026.106408
Change-of-Direction (COD) Biomechanics in Sport: A Systematic Review of the Possible Use of IMU
Russo, L., Chiari, L., Maremmani, D., Falchi, D., & Barni, L. (2026) · Biomechanics · doi:10.3390/biomechanics6030083
“As all the included studies were observational cross-sectional studies, methodological quality was assessed using the QUADAS-2 tool in order to ensure transparency in the evaluation of risk of bias and concerns regarding the applicability of primary diagnostic accuracy studies [39].”
Fernández, M. J., Verdugo, L. S. E., Tobar-Almache, D., & Vélez-León, E. M. (2026) · International Dental Journal · doi:10.1016/j.identj.2026.111118
Alramahy, M. A., Alramahy, B. A., Seidelin, J. B., Wetwittayakhlang, P., Bjerrum, J. T., & Attauabi, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15187024
“Each domain was classified as having low, high, or unclear risk of bias [18].”
Kabamba-Tshikongo, A., Manya-Mboni, H., Mwamba, C. M., Kabamba‐Mukadi, B., & Longanga-Otshudi, A. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117656
Bilan, F., Jafari, B., Gharesouran, J., Darabi, A. H. K., Tajeddini, S., Rezazadeh, M., & Ghafouri‐Fard, S. (2026) · Cancer Treatment and Research Communications · doi:10.1016/j.ctarc.2026.101437
McCarthy, R., Pink, J., Olivier, L., Gilbert, D. J., Mukherjee, R., & Cook, P. A. (2026) · Drug and Alcohol Review · doi:10.1111/dar.70233
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was used for quality assessment of the included studies [37] which evaluates study quality across four domains: patient selection, index test, reference standard and flow and timing.”
Intra- and intertumoral discordance of Claudin-18.2: a systematic review and meta-analysis
Vanneste, T. L. M., Sánchez, D. I. R., van der Mierden, S., Vollebergh, M. A., Kodach, L. L., van Sandick, J. W., Beets‐Tan, R. G. H., Snæbjörnsson, P., & Bodalal, Z. (2026) · ESMO Gastrointestinal Oncology · doi:10.1016/j.esmogo.2026.100412
“Risk-of-bias and applicability concerns were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool, 45 adapted to the present question, which focuses on the prevalence of discordance rather than diagnostic accuracy against a reference standard.”
Bai, Y., Huang, D., Liu, J., Li, Y., Zhai, J., Gan, T., & Li, J. (2026) · Cancer Screening and Prevention · doi:10.14218/csp.2026.00010
García-Hernández, A. B., Estrada-Villegas, G. M., Gómez‐Gómez, A. L., Salgado‐Cruz, M. D. L. P., & Landa, D. M. C. (2026) · Biosensors · doi:10.3390/bios16090511
Ordonez, F. B., Safar, I. E. M., Westfechtel, S. D., Rendón-Garavito, A. M., Truhn, D., Kuhl, C. K., Barabasch, A., & Nebelung, S. (2026) · European Radiology Abdomen · doi:10.1007/s44501-026-00006-4
“To complement this assessment, the QUADAS-2 tool [24] was additionally applied because PHLF prediction shares features of diagnostic test accuracy evaluation.”
Orman, M., Çeliker, D., Koca, B., Alis, D. C., Yücekul, A., Alanay, A., & Karaarslan, E. (2026) · Skeletal Radiology · doi:10.1007/s00256-026-05364-3
Hari Prasath, C., & Babu, T. A. (2026) · Journal of Ultrasound · doi:10.1007/s40477-026-01221-0
Shi, Y., Yin, X., Luo, J., Cheng, Y., Wei, Y., Shi, J., & Zhou, X. (2026) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2026.111926
Gao, R., & Li, X. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1771922
Liu, C., & Yu, D. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1909562
“The methodological quality and applicability of the included studies were independently assessed by two authors using the Quality Assessment of Diagnostic Accuracy Studies 2 instrument (QUADAS-2) developed by Whiting et al. (12).”
Post-Treatment High-Risk HPV Testing as a “Test of Cure”: A Systematic Review
Timis, G., Micu, R., Gaia‐Oltean, A. I., Goidescu, I. G., Nicula, R. L., & MOCAN, L. C. (2026) · Medical Sciences · doi:10.3390/medsci14050561
Artificial Intelligence in the Diagnosis of Superficial Mycoses: A Scoping Review
(Misăiloaie), D. M. L., Popescu, I. A., Vâță, D., Mocanu, M., & Solovăstru, L. G. (2026) · Journal of Fungi · doi:10.3390/jof12090684
Parkinson’s disease diagnosis using machine learning and multimodal biomarkers: A systematic review
Imran, M., Imran, A., & Alshammari, A. A. (2026) · Computational Biology and Chemistry · doi:10.1016/j.compbiolchem.2026.109388
Current Applications of Artificial Intelligence in Orthopaedic Trauma: A Narrative Review
Yadav, A., ., P., & Kumar, S. (2026) · International Journal of Science and Healthcare Research · doi:10.52403/ijshr.20260330
Abdulrahman, M. E. K., Abdalmagid, O. Y. O., Almardy, A. M. A., Elhassan, O. O. O. M., Haltem, I. A., Ahmed, A., & babekr, N. B. A. B. (2026) · Cureus · doi:10.7759/cureus.116168
Antkowiak, Ł., Rogalska, M., Kasperczuk, A., Kaspera, W., & Mandera, M. (2026) · Neurosurgical Review · doi:10.1007/s10143-026-04490-9
Al-Harthi, S. D., & Al-Anzi, H. B. (2026) · World Journal of Biology Pharmacy and Health Sciences · doi:10.30574/wjbphs.2026.27.3.0465
MACHINE LEARNING FOR EARLY DIAGNOSIS OF SMALL CELL LUNG CANCER: MULTI-OMICS BIOMARKER STRATEGIES
Masood, M., & Dai, Y. (2026) · International Journal of Science and Research Archive · doi:10.30574/ijsra.2026.20.3.1741
Ajay, P., Angmo, T., Gokul Krishnan, S., Shah, S. G., Shah, P., & Pandey, S. (2026) · Cureus · doi:10.7759/cureus.116197
“QUADAS-2 was reserved for studies with a true diagnostic-accuracy framework involving an index test and reference standard [18].”
Khan, S., Stasso, J. J., Melkus, G., Nguyen, T. B., & de Oliveira, E. P. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113253
Bustamante-Arias, A., Rosas-Apraez, A., Restrepo, C. A., Lizarazo, M. I., Tawse-Smith, D., Carreño, N. I., Holguín, L. D., Gatinel, D., Prada, M. R., Rocha, L. G., et al. (2026) · Clinical ophthalmology · doi:10.2147/opth.s612713 · Cited by 1
Hughes, S., Chan, P. T., Carle, C., Yuill, S., Barron, K., Luo, Q., Saya, S., Martínez-Gutiérrez, J., Sasieni, P. D., Taylor, N. J., et al. (2026) · JCO Oncology Practice · doi:10.1200/op-26-00570
Roy, M.-A., Gronnier, M., Désy, L., Pouliot, L., Lemaire‐Paquette, S., Lemieux, S.-È., Ramphul, M., Vézina, F.-A., Lachapelle, P., Duval, M., et al. (2026) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(26)00228-6 · Cited by 2
Social Working Memory: a Systematic Review
Pinheiro, M., Landeira-Fernández, J., Alves, M. V., Krahe, T. E., & Nórte, C. E. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09716-7
Szczepański, T., Jasiński, M., Koźba‐Gosztyła, M., Więcław, J., Szymczyk, P., Bladowska, J., & Czapiga, B. (2026) · Diagnostics · doi:10.3390/diagnostics16203291
Cianci, V., Sapienza, D., Gualniera, P., Asmundo, A., & Mondello, C. (2026) · American Journal of Forensic Medicine & Pathology · doi:10.1097/paf.0000000000001173
Kassayanan, P., Nontaprom, K., THREERATANANONT, A., THITINAN, N., & Suntipap, M. (2026) · European Journal of Obstetrics & Gynecology and Reproductive Biology X · doi:10.1016/j.eurox.2026.100494
“The quality assessment was independently performed by two reviewers (P.K. and K.N.) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [14], which assesses risk of bias across four domains and applicability concerns across the first three domains.”
Prameswari, A. S., Arsyil, F., Radityawan, D., & Novitasari, E. K. (2026) · Academia Open · doi:10.21070/acopen.11.2026.14501
Foundation Models in Medical Imaging: A Systematic Review, Taxonomy, and Future Research Agenda
Ghanim, R. (2026) · Academia Open · doi:10.21070/acopen.12.2027.15324
Hodson, D. Z., Tambelli, R. A., Wahab, M. A., Wallrauch, C., Steffen, H., Kreuels, B., Bélard, S., & Heller, T. (2026) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0014609
“Risk of bias was initially assessed by one author (TH) using an adapted QUADAS-2 tool for reviews of diagnostic accuracy (S2 Text) [38].”
Diagnostic Value of Serum Amyloid A in Neonatal Sepsis: A Literature Review
Stoia, B. A., Arbanaş, I., Spoulou, V. I., & Falup‐Pecurariu, O. (2026) · GERMS · doi:10.3390/germs16030023
Guimarães, H. H. D. S. D., & Matos, K. (2026) · International Orthodontics · doi:10.1016/j.ortho.2026.101249
McIver, W. J., Dillon, S., Schofield, K., Merritt, J., Morgan, D., Bangash, M. N., & Parekh, D. (2026) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-026-01503-2
Han, F., Wang, Q., & Shu, G. (2026) · Surgical Endoscopy · doi:10.1007/s00464-026-13265-8
“Risk of bias and applicability were assessed with QUADAS-2 [15].”
Barboza, J. J., Ramírez-Terán, Ó. A., Tomás-Alvarado, E., Barba, C. A., Cruz-Venegas, J. A. S., Jara, C. I. A., Cortez-Sandoval, M., López, B., Chura, E. T., Rios, O. A. B. H., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16183014
Yasmina, R. D., Simporé, A., Azaque, Z. A., Barro, M., Ouattara, M., Traoré, A. D. D., Savadogo, M., Traore, I. M. A., Zongo, N., Simporè, J., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-10590242/v1
Magnetic resonance imaging in identifying dysthyroid optic neuropathy: a systematic review
Zhou, J., Lu, J., Wan, Y., Qin, J.-T., Chen, H.-H., Liu, H., Xu, X., Hu, H., & Wu, F.-Y. (2026) · Visual Neuroscience · doi:10.48130/vns-0026-0040
Zhang, X., Liu, Z., Zhang, Y., & An, X. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.107054
Zare, O., Ostovari, M., & Mahmoudi, T. (2026) · Clinical Radiology · doi:10.1016/j.crad.2026.107484
Ovčariček, P. P., Campennì, A., Ruggeri, R. M., Punda, M., Gregov, A., Bejuk, A., Campennì, A. F., Huellner, M. W., & Giovanella, L. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15218255
de Haan, J., Neeter, L. M. F. H., Pijpe, A., Moormann, G., van Zuijlen, P. P. M., Harlaar, N. J., Penha, T. R. L., & Vries, A. M. (2026) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2026.09.018
Radiomics-based prediction of pituitary adenoma consistency: a systematic review and meta-analysis
Fusco, G., Caiazza, C., Cuocolo, R., Ungaro, G., Agosti, E., Solari, D., Caranci, F., Cirillo, M., & Ugga, L. (2026) · La radiologia medica · doi:10.1007/s11547-026-02281-2
“Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [15].”
Alzubaidi, R. H., Almania, A. I., Alamri, S. W., Bannan, H. A., Alanazi, A. K., Alqesair, M. H., Taher, A. H., Alruwaili, L. M., Alqarni, A. M., Alsharif, S. M., et al. (2026) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2026.113020
Learning Curve Threshold and Survivorship Bias
Shao, J., & Gu, J. (2026) · Journal of Ultrasound in Medicine · doi:10.1002/jum.70479
Ejlersen, M., Knold, J., Kumarathurai, P., Diederichsen, A. C. P., & Henriksen, F. L. (2026) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2026.2735712
Dinh, T., Lisik, D., Fournier-Viger, P. P., Tran, D., Yu, P. S., Hong, H. V., & Zou, D. (2026) · Frontiers in Sleep · doi:10.3389/frsle.2026.1927453
Jamileh, E., Elmewafy, A. T., Qadeer, M. A., Zulfiqar, Z., Kang, K., Hosseini, K., & Antoun, I. (2026) · Cardiology Research and Practice · doi:10.1155/crp/3289574
Bagwan, H. A., & Shinde, S. (2026) · Cureus · doi:10.7759/cureus.116512
Diagnostic Accuracy Of Fnac In Benign And Malignant Breast Lesions: A Systematic Review
Yogeetha., S., & Mythili., B. (2026) · PAIN JOINTS SPINE · doi:10.1922/pjs.16.3s.2026.579
Amirbeigy, M. K., Haddadi, A., Zarchi, A. A., & Sheikhalishahi, S. (2026) · Research Square · doi:10.21203/rs.3.rs-10740130/v1
Wu, H., Guo, Y., & Na, F. (2026) · Research Square · doi:10.21203/rs.3.rs-10777064/v1
Ling, M. P. S., Umbgrove, J. L., Wiggers, R. B. M., Vahrmeijer, A. L., van der Vorst, J. R., & Hazenberg, C. E. V. B. (2026) · Seminars in Vascular Surgery · doi:10.1053/j.semvascsurg.2026.09.005
Cha, M. H., Chung, H.-Y., & Choi, M.-K. (2026) · Journal of the Korean Dysphagia Society · doi:10.34160/jkds.26.009
Oliveira, C. W. D. M., Menezes, M. C. S., Valentim, L. Á., Belchior, H. A. F., Genari, T. S., Macêdo, C. V. D. A., Couto, E. S., de Toledo, V. A. C. P., Kudiess, B. G., Mariano, L. M. D. A., et al. (2026) · Congresso Brasileiro de Medicina de Família e Comunidade (CBMFC) · doi:10.29327/9786502184226.1652019
Mahgoub, A., Singh, A., Mahgoub, A., & Sharma, D. (2026) · Cureus · doi:10.7759/cureus.116649
“Study-level appraisal domains were informed by QUADAS-2, PROBAST, and CLAIM [13-15] and included unit independence, class balance, reference standards, patient-level splitting, leakage risk, clustered observations, confidence intervals, calibration, and applicability.”
Chen, L. R., Perry, M. B., Salomon‐Estebanez, M., Livesey, D., Martin, G. P., & Higham, C. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-125247
“44 QUADAS-2 is recommended by the National Institute for Health and Care Excellence, Cochrane and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) for assessing methodological quality and risk of bias in diagnostic accuracy studies.”
Diagnostic biomarkers for non-traumatic osteonecrosis of the femoral head
Dong, Y., Sun, J., Li, S., Zhang, J., Yan, Y., Li, T., & Jia, Y. (2026) · Bone and Joint Research · doi:10.1302/2046-3758.159.bjr-2026-0020.r1
Diagnostic accuracy of biological markers for detecting obstructive sleep apnoea
Canto, G. D. L., Pauletto, P., Stefani, C. M., Guerra, E. N. S., Pinto, A. C. P. N., Carvas, N., Flores‐Mir, C., Gozal, D., & Trevisani, V. F. M. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016281
Ciurescu, S., Buciu, V., Ilaș, D. G., Pârvănescu, R., & Șerban, D. M. (2026) · Diagnostics · doi:10.3390/diagnostics16183045
“…the conventional QUADAS-2 layout; readers unfamiliar with it will find the domain definitions and the signalling questions behind each judgement in the original tool description [27] and a practical account of how such summaries are built and read in the documentation of the robvis package [73].”
Olesen, A. S. O., Miger, K. C., Taraldsen, I. A., Lukoschewitz, J. D., Melgaard, E., Malm, E., Tonning, S. H., Westergaard, L. M., Haastrup, S. B., El‐Sheikh, M., et al. (2026) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2026.102015
“Risk of bias and applicability were assessed using QUADAS-2 [17], covering patient selection, index test, reference standard, and flow and timing.”
Accuracy of Deep Learning in Detecting Cerebral Microbleeds: Systematic Review and Meta-Analysis
Feng, Y., Zheng, L., Zhang, B., & Zou, W. (2026) · Journal of Medical Internet Research · doi:10.2196/95041
Devi, N. (2026) · Journal of Social Research Development · doi:10.59075/jsrd.v7i6.515
“Diagnostic or measurement-accuracy studies, where included, will be assessed using QUADAS-2, covering patient selection, index tests, reference standards, and flow and timing (Whiting et al., 2011).”
Diagnosis of Awake Bruxism in Adolescents and Young Adults: A Systematic Review
García-Moya, J., Roca, J. A. R., Pecci‐Lloret, M. P., Lucchese, A., Lauritano, D., & Pérez-Guzmán, N. (2026) · Dentistry Journal · doi:10.3390/dj14090606
“…Briggs Institute (JBI) Critical Appraisal Checklist for cross-sectional studies [8], randomised trials using the Revised Cochrane Risk of Bias Tool for Randomized Trials (RoB 2) [9], and diagnostic accuracy studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [10].”
Semenova, I., Lukianova, E. A., Belova, N. M., Васильевна, Д. З., Nalbandyan, K. G., & Korosteleva, E. (2026) · Russian Journal of Stomatology · doi:10.17116/rosstomat20261903145
Husain, H. A. A. H., Darwish, H. J. I. A., Ebrahim, E. I. E. H., Odeh, A. A., & Khan, R. T. Y. (2026) · Journal of Health Wellness and Community Research · doi:10.61919/sj24w964
Averin, D. A., Lobastov, K. V., & Laberko, L. A. (2026) · Journal of Venous Disorders · doi:10.17116/flebo202620031220
Husain, H. A. A. H., Darwish, H. J. I. A., Ebrahim, E. I. E. H., Odeh, A. A., & Khan, R. T. Y. (2026) · Journal of Health Wellness and Community Research · doi:10.61919/x6q10z84
Huang, K.-C., Wang, M. J., Chu, Y.-Y., Huang, R., Lu, Y.-J., Lin, C., Hsu, C., Chen, S.-H., Lin, Y.-T., & Lee, C. (2026) · Journal of Medical Internet Research · doi:10.2196/91174 · Cited by 1
“QUADAS-2 identified concerns regarding patient selection and index test methodology in several studies [71], and the GRADE assessment rated the certainty of evidence as low because of study limitations and substantial between-study heterogeneity [72].”
Gharat, M. G., Deshpande, S. M., Sethumadhavan, J., Gholap, P., Kale, S., Choudhari, S. K., & More, A. P. (2026) · Cureus · doi:10.7759/cureus.116745
“The methodological quality of the included studies was evaluated via Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) (Table 1 ) [19].”
Noori, M., Marlina, E., Permatasari, A. S., & Rahman, F. U. A. (2026) · Acta Odontologica Indonesia · doi:10.14710/actodont.31922
Blood biomarkers and artificial intelligence: toward precision medicine in Alzheimer’s disease
Xu, L., Tu, J., Zhang, J., Zhang, C., & Sun, Y. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1937244
“We used the modified Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool to assess the risk of bias (Whiting et al., 2011; Wade et al., 2013).”
Srada, Y. B., Bawazir, B., Aghi, S. M., ElSayed, M., Yousif, H., Ibrahim, M., Eltohamy, K. A., & Sim, M. (2026) · Clinics and Practice · doi:10.3390/clinpract16100181
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.