QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 14,501–14,600 of 14,770
Mcskimming, T., Xian, J. S. Y., RAMSAY, R., Cullen, F., Galbraith, N. J., Roxburgh, C. S. D., Kong, C. Y., & Steele, C. W. (2026) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2026.112194
Rab proteins as diagnostic biomarkers for Parkinson’s disease: a systematic review
Ravinther, A. I., Dewadas, H. D., Hou, R., Lee, N. T. E., Chien, C., Foo, C. N., & Lim, Y. M. (2026) · Advanced Pharmaceutical Bulletin · doi:10.34172/apb.45874
Kocemba, D., Ørskov, S., Carlsen, J. G., Schulz, M. K., Uhrbrand, B., Dinesen, H., Mikkelsen, R., Thygesen, M. M., & Rasmussen, M. M. (2026) · Journal of Neurosurgery Spine · doi:10.3171/2026.4.spine251222
Tumwesigye, H., Nabimanya, Birungi, A., Tumwesigire, S., Mitala, Y., & Atwine, R. (2026) · Research Square · doi:10.21203/rs.3.rs-11258913/v1
Brijlall, S. (2021) · University of the Western Cape Electronic Theses and Dissertations Repository (University of the Western Cape)
MRI-derived radiomics for prostate cancer active surveillance: a systematic review
Kyle, E. T., Sweeney, K. J., McCabe, D. H., O’Sullivan, N. J., Corr, A., Niall, S., Meaney, J., Lonergan, P. E., McLoughlin, L., & Kelly, M. E. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113291
Huang, Y.-B., Yin, J.-S., Shao, S.-Y., Jiang, P., Wang, Z.-L., & Xu, H. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1874937
“Two reviewers independently applied QUADAS-2 (17) across the four domains (patient selection, index test, reference standard, flow and timing).”
Ibe, B. C., Aly, A., Al-Juboori, S., Ifeachor, E., & Shankar, R. (2026) · JMIR Research Protocols · doi:10.2196/99551
“A modified version of the QUADAS-2 tool [30] adapted for AI-based diagnostic studies will be used as the AI-specific extension (QUADAS-AI) is still under development.”
de Sousa, D. F., de Menezes, R. N., Vieira, M. E. N. P., Oliveira, S. D. F., & Vieira, N. B. (2026) · doi:10.62642/tec-978-65-83199-83-6_015
AI‐Assisted Micronucleus Detection: A Critical Systematic Review With Quantitative Synthesis
Paul, S. (2026) · Cell Biology International · doi:10.1002/cbin.70225
“…available for over a decade, and the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) and TRIPOD + AI now offer field‐specific guidance addressing the missing items (Collins et al. 2024; Mongan et al. 2020; Whiting et al. 2011), these standards were not met in the included studies.”
Artificial Intelligence-Powered Contrast-Free Myocardial Scar Assessment
Hashmi, A. (2026) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2026.07.055
Caneba, J., Bansal, S., Reljic, T., Montecillo‐Aguelo, A., Alias, H., Amaranto, F., Aquino‐Calingasan, M. S., Ardianto, B., Arguni, E., Blair, S. J., et al. (2026) · Pediatric Blood & Cancer · doi:10.1002/1545-5017.70743
Aggarwal, A. (2026) · Journal of chemical health risks
Kristanti, N. L. G. T., Paramartha, I. G. N. B., & Pertiwi, N. K. O. D. (2026) · The Indonesian Journal of General Medicine · doi:10.70070/1hdaxw86
Torres, A. L. S., Santiago, R. D. S., Nascimento, M. H. C., de Melo, L. D. C., & Baraúna, V. G. (2026) · Conexão Ciência (Online) · doi:10.24862/cco.v21i3.2353
Mappa, I., D’Antonio, F., Ciolli, P., Derme, M., Maruotti, G. M., & Rizzo, G. (2026) · Medicina · doi:10.3390/medicina62101936
“Two reviewers independently applied QUADAS-2 [11], with signalling questions tailored to the review question, including items on whether verification of pregnancies not reaching live birth was pre-defined and on the material used, as well as on antiviral treatment received between the index test…”
Real-World Effectiveness of AI-Enabled Clinical Decision Support in Primary Care: Systematic Review
Jain, Y., Wu, D., & Wang, Z. (2026) · Journal of Medical Internet Research · doi:10.2196/98630
“…trial [14], the RoB 2 cluster-randomized extension for the 5 cluster trials [15], ROBINS-I (Risk of Bias in Non-Randomized Studies of Interventions) for nonrandomized intervention studies [16], and QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) for diagnostic accuracy studies [17].”
Adam, G. P., Davies, M. C., Caputo, E. L., Mai, H. J., Coppola, E. L., Holmer, H. K., Kuhn, E., Balk, E. M., Trikalinos, T. A., Ivlev, I., et al. (2026) · Research Synthesis Methods · doi:10.1017/rsm.2026.10118
Al-Ani, A., Pham, M. M., Mikhail, D., Alkhawaja, M., Dotchin, S. A., Ells, A. L., Newman, N. J., Subramaniam, S., Biousse, V., Costello, F., et al. (2026) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2026.10.004
Raza, A. A., Ahmad, M., Choudhary, N., Rehman, A., Zahid, M., Rehman, A., & Khan, W. (2026) · Injury · doi:10.1016/j.injury.2026.113760
Wang, J., Yin, Y., Qu, J., 陶仲宾, Chi, X., & Zhang, X. (2026) · PLoS ONE · doi:10.1371/journal.pone.0359310
Bueling, Z., Douri, D. R., Berg, A. H., Garrity, C. E., Olson, B. M., Riehl, B., Westby, C. M., Swan, J. T., Ghozy, S. A., Rabadi, I. A., et al. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.09.121
Nitz, J., Schubert, E., Müller, S., & Hennemann, T. (2026) · Frontiers in Education · doi:10.3389/feduc.2026.1936281
Horne, D. J. D. L., Zifodya, J. S., Ejara, E. D., Coston, T. D., Shapiro, A. E., Kohli, M., Schumacher, S. G., Hall, P., Korobitsyn, A., & Takwoingi, Y. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016396
Granerød, J., Sellner, J., Stahl, J., Defres, S., Mailles, A., Schmutzhard, E., Aurelius, E., Whitfield, T., Massacesi, L., Titulaer, M. J., et al. (2026) · European Journal of Neurology · doi:10.1111/ene.70647 · Cited by 2
Granerød, J., Sellner, J., Stahl, J.-P., Defres, S., Mailles, A., Schmutzhard, E., Aurelius, E., Whitfield, T., Massacesi, L., Titulaer, M. J., et al. (2026) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2026.03.009
Quirino, L. D. M., Duarte, K. X., Pereira, S. G. P. J., Leff, G. D., Rafael, B. C. C., Pinto, M. B. A., Lopes, R., Simões, C. S., Soares, J. W. D. A., & Kieling, G. L. (2026) · Cureus · doi:10.7759/cureus.117692
Shu, X., & Wen, X. (2026) · Biosensors · doi:10.3390/bios16100565
Cynthia, N. A., Olanrewaju, A. B., Obirinanwa, C. C., Buhari, S., Nnanna, J. C., Abah, M. A., & Abimbola, M. O. (2026) · Acta Pharma Reports. · doi:10.51470/apr.2026.05.01.108
Cross-Validation of Acoustic Roughness Index in Korean
Kim, G. H., Lim, D. W., Kim, N. R., Shin, B. Y., & Lee, Y. W. (2026) · Journal of Voice · doi:10.1016/j.jvoice.2026.09.039
Gutiérrez, G., & Papa, F. (2026) · Physiological Reports · doi:10.14814/phy2.71127
“Conventional diagnostic accuracy analyses assume that reference labels are correct; however, performance estimates may be systematically biased when this assumption is violated (Whiting et al., 2011).”
Wang, D., Wang, L., & Fang, Y. (2026) · Gynecological Endocrinology · doi:10.1080/09513590.2026.2732860
Andonov, V., Velchov, V., Nikolov, Y., Cherkezov, N., Tenev, D., Dimitrov, M., Tsenkov, T., & Dimitrov, N. (2026) · Diagnostics · doi:10.3390/diagnostics16203285
“It is incorporation bias in textbook form: the index test constitutes part of the reference standard against which it is assessed, a risk covered explicitly by the reference standard domain of QUADAS-2 [32], and it inflates apparent agreement in a way no larger sample corrects.”
Comparative accuracy of imaging modalities for differentiating malignant small testicular masses
Dua, Y., Maheshwari, A., Perera, M., Murphy, D. G., Lawrentschuk, N., & Sathianathen, N. J. (2026) · British Journal of Urology · doi:10.1111/bju.70492
Li, Z., Gong, K., & Liu, N. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1948193
Wen, Y., Zhong, J., Yang, Q., Shi, Z., Ouyang, J., & Tan, B. (2026) · European Spine Journal · doi:10.1007/s00586-026-10410-8
Wang, M., Yang, W., Li, Y., & Liu, B. (2026) · Clinical and Translational Imaging · doi:10.1007/s40336-026-00806-3
KHOZHAMKUL, F., & SHARMAN, A. (2026) · Vestnik · doi:10.53065/kaznmu.2026.78.3.004
Darfarin, K., Hajizadehanari, N., rad, S. S., Jafari, M. A., DolatAbadi, M. T., Hasanzadeh, F., Fekri, M., & Ebrahimi, R. (2026) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2026.107972
Cao, R., Qilin, R., Xu, L., Tang, Y., Bao, Q., Zhang, H., Wang, J., & Zhu, X. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.107101
Maltsev, D., Fedoryshyn, H., Мисловська, С., Якименко, В., & Александрук, О. (2026) · Journal of Pioneering Medical Science · doi:10.47310/jpms2026150938
Camino, E. P. C., Yamberla, G. E. Y., Gaibor, D. T. P., Jiménez, J. C. Á., & Arévalo, M. A. R. (2026) · Salud Medicina e Innovación Journal · doi:10.70577/7tdr9f39
“Evaluación del riesgo de sesgo La calidad metodológica de los estudios incluidos se evaluó mediante la herramienta QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies), diseñada específicamente para revisiones sistemáticas de precisión diagnóstica (Whiting et al., 2011).”
Singh, B., Mahuli, A. V., Jha, A. K., Kumar, S., Ranjan, M., & Chandra, S. (2026) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-4099
Sait, M., & Almutairi, F. (2026) · Diagnostics · doi:10.3390/diagnostics16203308
Li, J., Suppiah, S., Kasilingam, L., Hui, S. T., Shi, H., Lee, S. T., Sharin, M. F. M., & Al-Ibraheem, A. (2026) · Frontiers in Medical Engineering · doi:10.3389/fmede.2026.1979078
Bakir, M., & Shrestha, R. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2749580
Gupta, N., Goel, A. D., Agrawal, S. P., Prasad, V. P., & Maturu, V. N. (2026) · Respiratory Investigation · doi:10.1016/j.resinv.2026.101522
Villegas-Gomez, G. A., Vega-Alvear, R. F., Ordóñez-Rubiano, E. G., Gómez-Amarillo, D. F., Ramón, J. F., Romero-Bustos, J. A., Medina-Centanaro, L. J., Ruiz, W., Giraldo, S. I. L., Suárez-Mera, J. D., et al. (2026) · Neurosurgical Review · doi:10.1007/s10143-026-04526-0
“Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used for the diagnostic discrimination report [ 18 , 21 ].”
Song, L., Zhang, J., Shaharuddin, B., & Wang, Z. (2026) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2026.2742200
Rodrigues, G. M., Guimarães, S. B., Thome, A. K. D. U., Cavalcante, J. V. S., Rezende, L. F. F., & Borges, S. P. (2026) · LUMEN ET VIRTUS · doi:10.56238/levv17n65-027
Kamra, S., Moon, D., Green, N., & Vandewalle, B. (2026) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2026.2732596
Guimarães, S. B., Rodrigues, G. M., Thome, A. K. D. U., Cavalcante, J. V. S., Demétrio, G. F. P., Rezende, L. F. F., & Borges, S. P. (2026) · LUMEN ET VIRTUS · doi:10.56238/levv17n65-028
Innovación en Inteligencia Artificial y Nuevas Tecnologías en la Medicina del Deporte y el Fútbol
Cisneros, A. E. R., Peláez, J. P., Sánchez, G. V., Gonzalez, A. M. L., & BALLESTEROS, F. H. G. (2026) · Ibero Ciencias - Revista Científica y Académica · doi:10.63371/ic.v5.n3.a1720
Merson, L., Ndoye, A. M., Bailey, R., Barry, A., Dia, N., Dramé, N. D., Diallo, O. N., Dieng, I., Faye, J., Kabo, K., et al. (2026) · doi:10.12688/verixiv.3554.2
Hussin, A. Y. A., Elnaseeh, W. M., Majzoub, R. A., Jabr, I. K. A., Babekr, N. B. A., & Almaghnam, T. F. (2026) · F1000Research · doi:10.12688/f1000research.191423.1
Elhaie, M., & Koozari, A. (2026) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2026.100497
Paganin, W., Procenesi, L., Gorea, F., & Lorenzo, G. D. (2026) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2026.10.014
Digital screening tools for individuals at risk of mental disorders: a systematic review (Preprint)Preprint
Logeswaran, Y., La‐Torraca‐Vittori, P., Ahmed, M. W., Arribas, M., Wallman, P., Reilly, T. J., Capon, W., Aronica, R., Brodeur, S., Dusara, H., et al. (2026) · doi:10.2196/preprints.114283
Prosser, J., Hatfield, J., Roe, T., Gray, H., Keld, A., Firth, A., McClean, L., Stedman, N., Smith, G., Carradice, D., et al. (2026) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2026.09.054
Yelzhassov, A., Tolegenuly, A., Erpashov, A., Leontyev, S., Chinybayeva, A., Abdrakhmanov, A. S., Ganina, A., & Abdinurov, A. (2026) · Journal of Clinical Medicine of Kazakhstan · doi:10.23950/jcmk/19615
Choudhary, A. K., Hait, A., & Baladaniya, M. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1958980
“…of bias was appraised with instruments matched to study design: the revised Cochrane RoB 2 tool for randomised trials (29), ROBINS-I for non-randomised intervention/observational evidence (30), QUADAS-2 for diagnostic accuracy studies (31), and AMSTAR 2 for systematic reviews/meta-analyses (32).”
Maffulli, N., Padulo, J., & Oliva, F. (2026) · British Medical Bulletin · doi:10.1093/bmb/ldag037
“Methodological quality and risk of bias were assessed with QUADAS -2, tailored to the review question across the domains of participant selection, index test , reference standard, and flow and timing [ 17].”
Alassal, M. F. M., Alshamari, T., Rezaei, A., & Shaikh, F. M. (2026) · Diagnostics · doi:10.3390/diagnostics16203341
“For the three studies contributing diagnostic accuracy data, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was applied [17].”
Singh, V., Gunda, S., Shah, A., Mathew, J., & Ravendran, K. (2026) · Journal of Imaging · doi:10.3390/jimaging12100509
Liao, Y.-S., Deng, Y.-P., Song, J.-L., Yu, X., Li, Q., Lu, B., & Chen, G.-Y. (2026) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2026.1934020
“Certainty was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework across risk of bias, inconsistency, indirectness, imprecision, and publication bias domains (Whiting et al., 2011; Schunemann et al., 2008).”
Latcu, S., Novacescu, D., Baloi, A., Zara, F., Dumitru, C.-S., Caprariu, R., Cut, T. G., Marinescu, A., Lazureanu, V. E., Bratosin, F., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16203334
Conteh, J. Y., Kapucu, N., Ebevuhe, E. F., & Adeniji, O. W. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1955958
“Studies evaluating diagnostic AI models were critically appraised using QUADAS-2 (34), which evaluates risk of bias and applicability across four domains: patient selection, index test, reference standard, and flow and timing.”
InfluentialGUIDE: computationally augmented consensus for trustworthy clinical practice guidelinesPreprint
Lin, Y., Di, J., He, X., Lin, Z., Chen, J., Li, R., Zheng, C., Shang, Y., Peng, W., Qin, J., et al. (2026) · Research Square · doi:10.48550/arxiv.2610.16108
Accuracy of Diagnostic Methods for Peripheral Trigeminal Nerve Injuries: A Systematic Review
Varvara, G., Burdo, P., Gerardi, D., Lozza, A., & Biglioli, F. (2026) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2026.10.006
Dajti, E., Qi, X., Chen, J., Ştefănescu, H., Cho, Y. S., Cassinotto, C., Gaspar, R., Crocè, L. S., Elsabaawy, M., Fraquelli, M., et al. (2026) · JHEP Reports · doi:10.1016/j.jhepr.2026.102066
Albano, D., Tasevski, S., Rapa, M., Nanni, C., & Treglia, G. (2026) · Cancers · doi:10.3390/cancers18203305
Bukhari, S. M. H., Shahid, U., Qayyum, W., Amjad, A., Qayyum, S., & Aleem, A. (2026) · Cureus · doi:10.7759/cureus.117908
“Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate patient selection, index test assessment, reference standard, and flow and timing [17].”
Siqueira, D., de Souza, H. C. M., Queiroz, H. E. V., Xavier, D., de Souza, R. J. P., Fernandes, J., Campos, S. L., Brandão, D. C., Dantas, D. D. S., & de Andrade, A. D. (2026) · European Geriatric Medicine · doi:10.1007/s41999-026-01619-3
Omer, O. K. A., Abdallah, H., Salman, A. K. A., Mohamedsalih, E. M. O., Abdalla, A. A. E., Adam, A. A. A., Mohamed, R. O. B., Mohammed, W., & Albadwy, A. (2026) · Cureus · doi:10.7759/cureus.117910
Reliability and validity of the cervical flexion rotation test: systematic review and meta-analyses
Jones, M., Noronha, M. A. D., Selistre, L. F. A., & English, D. J. (2026) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2026.10.015
Alzahrani, A. J. (2026) · Journal of Global Antimicrobial Resistance · doi:10.1016/j.jgar.2026.10.002
Wang, G., Nie, C., & Liu, M. (2026) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70857
Patient safety and health equity of AI-enabled triage tools in primary care: a systematic review
Alamoudi, A., Gai, Y., Zghebi, S. S., Kontopantelis, E., & Brown, B. C. (2026) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2026-102427
A systematic review of non-contact medical IoT systems for physiological biomarker monitoring
Banik, B., Ghose, S., Nahiun, A. H., Lin, Y., Shalaginov, A., & Ghose, D. (2026) · Frontiers in Medical Technology · doi:10.3389/fmedt.2026.1917332
“Radar performance degrades with angular offset beyond 30 � and at low SNR (38), and nearby metal surfaces raise HR error from under 4 bpm to approximately 14 bpm (37).”
Qelmi, T. S., Raditya, A. F., Nandini, K. A., & Kencono, C. D. (2026) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2026.32.1.2580
Kim, J. W., Kim, H. J., Lee, E., & Kwon, S. (2026) · Cancers · doi:10.3390/cancers18203332
“Risk of bias and applicability were evaluated across four domains using QUADAS-2 [15], with signaling questions tailored to the review question beforehand.”
InfluentialMachine learning in semen analysis for male infertility: A systematic review and future directions
Varzaneh, Z. A., Khoshkangini, R., Saeedi‐Boroujeni, A., & Kazemi-Arpanahi, H. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106766
Kachmar, V., Mikhlin, R., Danko, T., & Shmal, A. (2026) · Cureus · doi:10.7759/cureus.117978
Berikkhanov, Z. G. M., Akulov, Z. A., Ekaterina, K., Pogosyan, D., Tarabrin, E. А., Shestakov, A., Kotelnikov, A., Nikolaev, A., Razumovsky, V. S., Ivanova, M. Y., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16203360
Choi, S. J., Zhang, H., Lee, J. H., & Yoon, S. H. (2026) · Yonsei Medical Journal · doi:10.3349/ymj.2025.0233
Wang, J., Wang, J., Zhang, Y., Xiao, D., Zhang, C., Wang, X., Xu, H., & Mao, J. (2026) · Pediatric Surgery International · doi:10.1007/s00383-026-06654-6
“Risk of bias was assessed using a review-specific adaptation of QUADAS-2 [ 2 ].”
Alrasheed, A. S., Aljedani, H. A., Nasraldin, F. E., Baajajah, A. M., Justenia, L. A., Alqahtani, M. S., & Almatrafi, F. R. (2026) · European Spine Journal · doi:10.1007/s00586-026-10411-7
Guerra, K. S. A.-H., Rodrigues, I., Abi-Habib, Y. G. S., & Vita, D. T. P. (2026) · Aposta · doi:10.23900/ra.v24i123.001
Guo, J., Liu, X., Zhang, H., & Wei, S. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1907483
“The QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool was used to evaluate the applicability and risk of bias of the included studies (20).”
Wang, C., Liu, X., Yan, C., & Dang, X. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.09.060
Диагностическая точность теста с пассивным подъемом ног: систематический обзор и сетевой метаанализ
Я., Я. М., Б., Б. Л., В., К. И., В., Р. П., Г., Я. А., А., Я. А., & В., Л. В. (2026) · Patologiya krovoobrashcheniya i kardiokhirurgiya
Artificial Intelligence–Based Gait Analysis in Neurological Rehabilitation: A Systematic Review
Kalal, D. (2026) · Journal of AI-powered medical innovations. · doi:10.60087/japmi.vol.04.issue.02.id.004
“If a single reviewer performs the assessment, this limitation will be acknowledged [16, 17, 27].”
Ayadi, M. G., Ghazouani, A., & Achour, H. (2026) · Network Modeling Analysis in Health Informatics and Bioinformatics · doi:10.1007/s13721-026-00890-5
“We assessed the quality and risk of bias of included stud - ies using validated tools (Whiting et al. 2011, 2016) appropriate to the diverse study designs in our review.”
InfluentialWang, H., Guo, D., Gao, Y., Xian, W., & Zhang, L. (2026) · Medicine · doi:10.1097/md.0000000000050739
Bratosin, F., Branea, H. S., & Hogea, E. (2026) · Diagnostics · doi:10.3390/diagnostics16203375
“Denominator-based cohorts were appraised with QUADAS-2 domains (patient selection, index test, reference standard, flow and timing) supplemented by whether clinical-impact criteria were prespecified and adjudicated independently of the index test [29].”
Ramos, J. M., & de Melo, M. D. T. (2026) · ARQUIVOS BRASILEIROS DE CARDIOLOGIA - IMAGEM CARDIOVASCULAR · doi:10.36660/abcimg.20260097
Liu, X. T., Han, Y. Y., Mi, X. L., Xiao, Q. M., Wang, W. Z., & Wen Pin, X. U. (2026) · Medicine · doi:10.1097/md.0000000000050975
“[7] QUADAS-2 comprises 4 domains: patient selection, index test, reference standard, and flow and timing.”
Zheng, Z., Yang, J., Dang, X., Ren, Z., & Feng, Q. (2026) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2026.106135
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.