QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 14,201–14,300 of 14,770
Ömür, S. E., & Zorlu, Ç. (2026) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2026.154431
Han, X., Wang, Q., Gao, L., & Cao, H. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1938767
“To assess the methodological quality of the included studies, we adapted the Quality Assessment of Diagnostic Accuracy Studies – 2 (QUADAS-2) tool (21) to align with the objectives of this review, drawing on the quality and risk-of-bias assessment approach used in a previous related review (22).”
Feyissa, M., Ng, A., Chan, K., Ahmed, B., Davies, P., Alomari, M., Philippou, Y., Muheilan, M., Linehan, J., Lau, C., et al. (2026) · Journal of Clinical Urology · doi:10.1177/20514158261472025
Fagerhaug, T. M., Kjeldsen, M. H., Maagaard, M., Homøe, P., & Hvilsom, G. B. (2026) · Endocrine Oncology · doi:10.1530/eo-25-0097
Wysocka, K. (2026) · Polski Przegląd Otorynolaryngologiczny · doi:10.5604/01.3001.0055.8751
Filippidis, P., El-Khoury, C., Cruciani, M., Alanio, A., Barnes, R. A., Bialek, R., Buitrago, M. J., Donnelly, J. P., Grolimund, R., Hagen, F., et al. (2026) · Journal of Clinical Microbiology · doi:10.1128/jcm.00721-26
The Relationship Between Non-Suicidal Self-Injury and Executive Functions: A Meta- AnalysisPreprint
Feng, J., Hao, Y.-Z., Cui, J., Chen, G., Yang, T., & 王亚 (2026) · Research Square · doi:10.21203/rs.3.rs-10372268/v1
Bao, M., Wang, Y., Zhang, N., Wang, J., & Li, J. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1891900
“Diagnostic test accuracy studies were appraised using the QUADAS-2 instrument (40).”
Alhassan, L., Alrabadi, B., Batarseh, S. F., Alghzawi, Y., Bandak, N., Badwan, A., & Alkayed, H. A. (2026) · Immunotherapy · doi:10.1080/1750743x.2026.2717074
Coronel-Zubiate, F. T., Soto, C. M., Meza-Málaga, J. M., Luján-Valencia, S. A., Placeres-Hernández, A., Carmona-Sanchez, A. V., Cruzado-Oliva, F. H., Farje-Gallardo, C. A., Rojas, J. Z., Luján-Urviola, E., et al. (2026) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2026.1820984 · Cited by 1
Huang, H., Liu, L., Feng, T., Shen, Q., Hua, X., & Wu, J. (2026) · Annals of Intensive Care · doi:10.1016/j.aicoj.2026.100136
“The quality of included studies was scored independently by two reviewers(HHJ and LLQ) using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria [29].”
The Role of Syndecan-1 in the Diagnosis and Prognosis of Post-Tourniquet Syndrome
Кryvoruchko, І. А., & Farzullayev, N. N. (2026) · The Ukrainian Journal of Clinical Surgery · doi:10.26779/2786-832x.2026.4.102
Alghazo, O., Milton, T. J., Wilson, K., Hiwase, M. D., Hofman, M. S., Hong, M. K. H., Jay, A., & O’Callaghan, M. (2026) · Clinical and Translational Imaging · doi:10.1007/s40336-026-00793-5
“M) independently assessed the quality of the included studies using customised questionnaires based on the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria [ 12 ].”
Yadav, S., Mehra, M., Yadav, R., & Singh, A. (2026) · Adolescencia e Saude · doi:10.67440/ahj.v21i3s.1578
“…degree of variability. described the first case with HIV and CSF Meningitis with greater sensitivity with the CBNAAT Ultra variant, while most other studies described only a slight increase in sensitivity, with the TB test still lacking the ability to rule out the disease [11, 12, 13, 14].”
Heck, R. S., Lins, R. S., Speransa, D. M. R., López, P., & Michelin, L. (2026) · International Journal of Endocrinology · doi:10.1155/ije/6364693
Alredha, R. D. A., Haddawi, K. H., & Hadi, S. H. (2026) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-026-02622-2
“Two-gate case– control designs of this kind systematically overestimate accuracy, with empirical evidence indicating a roughly three-fold inflation of the diagnostic odds ratio compared with studies performed in a consecutive clinical population [43–45].”
Zhang, P., Huang, D., Lu, X., Zhong, H., Liu, C., Liu, H., Duan, X., & Wu, J. (2026) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-026-02353-4
“The quality of studies included in the meta-analysis was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) [23].”
Ben, Y., Li, H., Chen, R., & Tang, Q. (2026) · Journal of Neurology · doi:10.1007/s00415-026-14061-z
“Methodological rigor was appraised with the Cochrane Collaboration-endorsed Quality Assessment of Diagnostic Accuracy Studies, version 2 (QUADAS-2) [11].”
Linde, K., Fomenko, A., Aktürk, Z., Eck, S., Hapfelmeier, A., & Schneider, A. (2026) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2026.112967
Lu, X., Qi, W., Hu, Y., Zhao, L., & Dai, H. (2026) · Journal of Neurology · doi:10.1007/s00415-026-14079-3
“Risk of bias and applicability were assessed independently by two reviewers using QUADAS-2 across patient selection, index test, reference standard, and flow and timing domains [18].”
Calabrese, E., Shehata, D. G., Slater, B. J., Beffa, L. R., Carlson, D. A., Daly, S., El-Hayek, K. M., Ignacio, R., Maddern, G., Mittal, S., et al. (2026) · Surgical Endoscopy · doi:10.1007/s00464-026-13231-4
“QUADAS-2 was used to determine RoB in diagnostic accuracy cohort studies for KQ 1 [18].”
Deo, V. K., & Taran, S. (2026) · International Conference on Smart Systems and Inventive Technology (ICSSIT) · doi:10.1109/icssit69151.2026.11656473
“Study quality was appraised using QUADAS-2 criteria [10] across patient selection, index test conduct, reference standard, and flow and timing domains.”
Bondjers, K., Willebrand, M., & Arnberg, F. K. (2026) · European Journal of Psychotraumatology · doi:10.1080/20008066.2026.2705788
“Reporting follows the Standards for Reporting Diagnostic Accuracy (STARD) statement and the Quality Assessment of Diagnostic Accuracy Studies guidelines (QUADAS-2; see Appendix A) (Bossuyt et al., 2015; Whiting et al., 2011).”
Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis
Kato, S., Azuma, M., Horita, N., Kinoshita, M., Iwahashi, T., Yasuda, N., Sawamura, S., Ishiwata, Y., & Utsunomiya, D. (2026) · European Radiology · doi:10.1007/s00330-026-12829-5
Asadpour, A., Sharma, R., Suklan, J., Kidd, S. P., Hart, J., Edwards, A. D., & Needs, S. H. (2026) · JAC-Antimicrobial Resistance · doi:10.1093/jacamr/dlag170
Samaniego, S. V. C., Toledo, J. P. P., Guerrero, D. A. S., & Caicedo, G. P. C. (2026) · ASCE MAGAZINE · doi:10.70577/asce.v5i3.1084
Cuenca, M. D. L. Á. A., Veintimilla, B. N. C., Chacón, F. B. H., Valdivieso, D. G. E., & Caicedo, G. P. C. (2026) · ASCE MAGAZINE · doi:10.70577/asce.v5i3.1085
de Moraes, F. C. A., Matheus, G. T. F. U., Rego, L. H. R. M., Pedreira, E. N., Chen, E., & Burbano, R. M. R. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2725657
Shen, L., Altmayer, S., & Tse, J. R. (2026) · Clinical Radiology · doi:10.1016/j.crad.2026.107465
AlMoshary, M., Alharbi, A. A., Alzarea, E. A., Alfaraedi, A., Alswailmi, O. A., Gad, L. A., Abdalhabib, E. K., Aldosari, M. S., Morsy, M. H., Alsahly, M. B., et al. (2026) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.70229
Wang, S., Yao, X., Zhang, X., Chen, J., Han, P., & Bai, W. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-1075
“QUADAS-2 emphasizes that the quality assessment of diagnostic accuracy studies should consider patient selection, index test, reference standard, and fl ow and timing to determine whether study results may be a ff ected by systematic bias [16].”
Shoorgashti, R., Lesan, S., Ehsani, S., & Yazdanfar, A. (2026) · Health Science Reports · doi:10.1002/hsr2.73086
Multisensory dysfunction across sleep disorders: A systematic review of 31 human modalities
Biabani, N., Ferri, R., Naismith, S. L., Mutti, C., Puligheddu, M., Parrino, L., Goadsby, P. J., & Rosenzweig, I. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102363
Methods for conducting searches in healthcare reviews: A systematic review
Clark, J. M., Beller, E., Forbes, C., Furuya‐Kanamori, L., & Sanders, S. (2026) · Research Synthesis Methods · doi:10.1017/rsm.2026.10112
Liu, H., Zhang, G., Li, Z., Zhang, T., Zhang, L., & Li, Y. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1922791
“Methodological quality of the 10 included studies was evaluated using the QUADAS-2 tool (31).”
Ardila, C. M., Pineda‐Vélez, E., & Díaz-Laclaustra, A. I. (2026) · Dental Traumatology · doi:10.1111/edt.70122
Eltaher, B., Mahmoud, A. A., Balusu, K., Manshahia, P. S., Abdelhay, A., Reghis, M., Ng, S., Afzal, A., Sanfilippo, K. M., & Patell, R. D. (2026) · European Journal Of Haematology · doi:10.1111/ejh.70306
Biofluid Biomarkers of Ischemic Penumbra in Acute Ischemic Stroke
Kawamura, Y. I., Liebeskind, D. S., Misra, S., Khan, E. I., Elshahat, A., Chook, P. Y., Wang, E. Y., Reed, M. E., Funaro, M. C., Tiwari, P., et al. (2026) · Neurology Open Access · doi:10.1212/wn9.0000000000000169
Patabendige, S., Falster, C., Langkilde, H. Z., Harders, S. W., Bendstrup, E. M., Skaarup, S. H., Durheim, M. T., & Davidsen, J. R. (2026) · Diagnostics · doi:10.3390/diagnostics16172759
“Methodological quality and risk of bias were independently evaluated by two re-viewers using QUADAS-2, as prespecified in the prospectively registered PROSPERO protocol [11].”
Henderson, D., Niederegger, T., Munzinger, R., Karakas, E., Hildinger, J., Iske, J., Heiland, M., Cetrulo, C. L., Lellouch, A. G., & Knoedler, L. (2026) · Transplantation Reviews · doi:10.1016/j.trre.2026.101054
Barros, C. N., Mayer, R. A., García-Borreguero, D., Álvaro, A. R., & Gaspar, L. S. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102364
Sachinis, N. P., Bhardwaj, V., Scaglia, M., Gerace, F., Messina, J. C., Randelli, P. S., & Arrigoni, P. A. (2026) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2026.08.017
Tang, X., Chen, J., Huang, Y., & Yao, Q. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106690
Diagnostic accuracy of delirium screening tools in the emergency department: A network meta-analysis
Lin, Y.-C., Shiao, Y.-C., Chen, W.-T., Hsu, C., Thompson, T., Carvalho, A. F., Stubbs, B., Tseng, P., Yang, W.-W., Tu, Y., et al. (2026) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2026.08.050
Wan, J. H., Hasikin, K. B., Mun, K.-S., & Tan, Y. (2026) · Pediatric Surgery International · doi:10.1007/s00383-026-06576-3
Khatri, K., Karki, S., Subedi, S., Paudel, S. S., & Pokhrel, A. (2026) · Research Square · doi:10.21203/rs.3.rs-10746334/v1
Yadav, S., Khurana, U., Sharma, V., Bais, S. S., Yadav, A., & Bhardwaj, K. S. (2026) · Abdominal Radiology · doi:10.1007/s00261-026-05765-x
INOUE, S., Nakashima, K., Nakashima, K., Kunihisa, T., Hirokaga, K., Tane, K., Goto, Y., & Nakayama, T. (2026) · Journal of Medical Ultrasonics · doi:10.1007/s10396-026-01682-0
Localizing value of ictal déjà vu, déjà vécu, dreamy state and reminiscence: A systematic review
Janah, A., Goldstein, L., & Fahoum, F. (2026) · Epileptic Disorders · doi:10.1002/epd2.70383
Akankwasa, P., Kakooza, J., Namutosi, E., Katongole, J., Hakizimana, T., Kasujja, M., Nabushawo, F., Lewis, C. R., & Okurut, E. (2026) · Journal of International Medical Research · doi:10.1177/03000605261480854
Raghavan, R., Shajahan, P. A., & Akash, R. (2026) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20263120
Abusalah, M. A. H. A., Abusalah, M. A. H., Raheem, S., Abuarqoub, A. H., Yusof, W., Yean, C. Y., Mohamed, Z., Atoom, A. M., & Elmi, A. H. (2026) · SAGE Open Medicine · doi:10.1177/20503121261484090
Chung, C. R., Yeo, H. J., Do, J. G., Na, Y., Choi, E., Kang, J., Kwon, J., Kim, H. J., Park, J., Lee, H., et al. (2026) · Acute and Critical Care · doi:10.4266/acc.006630
“These clinical practice guidelines were developed de novo by a multidisciplinary panel through systematic evidence synthesis, the GRADE framework, and a structured consensus process [22,23].”
Sonvivith, D., Balaji, A., Sridhar, J., Kumar, A. A., & Singh, D. T. (2026) · PAIN JOINTS SPINE · doi:10.1922/pjs.16.5s.2026.757
“Methodological quality and applicability were assessed with the QUADAS-2 instrument across its four domains—patient selection, index test, reference standard, and flow and timing— with the first three domains additionally rated for applicability [35].”
Wang, H. N., Huang, C. K., Huang, Y.-E., Huang, Y. T., Chan, S. H., & Tseng, J. (2026) · Revista Española de Medicina Nuclear e Imagen Molecular · doi:10.1016/j.remn.2026.500341
Bharwani, A., Bunchit, W., Pirani, R., Kishibe, T., Angriman, F., Ferguson, N. D., Pivetta, E. E., Goffi, A., & Rochwerg, B. N. (2026) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-026-03179-3 · Cited by 1
Mainwaring, E., Guidozzi, N., James, J. P., Pantling, J., Menon, N. S., Salem, R., & Markar, S. R. (2026) · Surgical Endoscopy · doi:10.1007/s00464-026-13309-z
Wang, Z., Zheng, Z., Jian, Y., Yin, J., & Zhang, J. (2026) · Surgical Oncology · doi:10.1016/j.suronc.2026.102545
Almudaimeegh, L., Alwashmi, K., & Hamd, Z. Y. (2026) · Diagnostics · doi:10.3390/diagnostics16172806 · Cited by 1
“Methodological quality and risk of bias were appraised using a QUADAS-AI framework [20] adapted from QUADAS-2 for deep learning medical-imaging studies (Supplementary File S4), with seven domains: Each domain was rated as low, unclear, or high risk of bias.”
Cheng, K., Chen, S.-Y., & Yang, L. (2026) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2026.106255
Jongthawin, J., Mahittikorn, A., Wangdi, K., Masangkay, F. R., & Kotepui, M. (2026) · Tropical Medicine and Infectious Disease · doi:10.3390/tropicalmed11090249
What Is the Diagnostic Accuracy of Individual Clinical Findings for Pediatric Concussion?
Raukar, N. P., & Long, B. (2026) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2026.07.014
Measurement Properties of Delirium Tools in Pediatric Intensive Care: A Systematic Review
Zilezinski, M., Denninger, N.-E., Müller, M., Tannen, A., & Kottner, J. (2026) · PEDIATRICS · doi:10.1542/peds.2026-077184
Bassett, C., Hruschka, B., Mohapatra, S. R., Frankort, J., Riedl, P., Kalkum, E., Uhl, C., Gombert, A., & Doukas, P. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15176756
“…using a purpose-built assessment tool developed specifically for this review, based on key domains of two established frameworks, QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) [20] and COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) [21].”
Luu, M. N., Trinh, N. A., Tran, T. L. T., Dang, T. P., Hiyama, T., & Quach, D. T. (2026) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2026.08.036
Hafner, S., Hidaka, Y., Paul, J. L., Hörtnagl, C., & Zechmeister‐Koss, I. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1824057
“…study by Lawson et al. (30), QUADAS-2 was considered the most appropriate tool for evaluating its diagnostic performance component because the prospective cohort study compared a digital index assessment with a reference assessment and reported agreement and diagnostic performance measures (31).”
Gündüz, S., & Güven, S. (2026) · Pediatric Research · doi:10.1038/s41390-026-05391-9
Arévalo, M. A. R., Cayambe, N. T. Á., Jaya, M. E. E., Flores, S. I. E., & Sanmartín, N. S. A. (2026) · ASCE MAGAZINE · doi:10.70577/asce.v5i3.1101
Wang, M., Hong, C., Huang, Z., Shao, F., & Gu, Y. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001635
Yang, E. J., Chung, S. H., Cho, J. H., Suh, M. R., Jeon, H. R., Cha, H. G., Lee, J. Y., & Choi, J. Y. (2026) · Clinical Breast Cancer · doi:10.1016/j.clbc.2026.08.024
Kangalgil, M., Meral, B., & Küçük, E. (2026) · Nutrition Reviews · doi:10.1093/nutrit/nuag120
Lian, B., Ye, C., Li, F., Qin, H., Zhou, L., Wei, C., & Yang, H. (2026) · Journal of International Medical Research · doi:10.1177/03000605261474642
Shah, A., Habib, S., Bhat, M. H., Shera, T. A., Maqsood, S., Wani, A. H., & Jabeen, S. (2026) · South Asian Journal of Cancer · doi:10.25259/sajc_19_2025
Dubreuil, M., Danve, A. S., Liew, J. W., Alexander, S. A., Afinogenova, Y., Bittar, M. N., Fraenkel, L., Grimshaw, A., Kumthekar, A. A., LaValley, M. P., et al. (2026) · ACR Open Rheumatology · doi:10.1002/acr2.90129
Inflammatory biomarkers in pediatric PFAPA syndrome: a systematic review
Treichel, P., Kołtan, S., & Styczyński, J. (2026) · Frontiers in Pediatrics · doi:10.3389/fped.2026.1934055
Walker, K., Michael, J., Ballard, M., Chilvers, G., Colley, S., Hussain, K., & Rickard, L. (2026) · Ultrasound · doi:10.1177/1742271x261479402
Yu, G., Ling, Y., Du, K., & Shen, Y. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-124499
Hussaini, H., Bano, S., Elyan, E., & Moreno‐García, C. F. (2026) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-026-02249-8
Gao, Y., & Chen, J. (2026) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2026.1911702
“…meta-analyses, studies with limited included researches, selected samples, or unclear interpretation of results may lead to an overestimated evaluation of diagnostic accuracy, which should be prudent when summarizing the conclusions of the meta-analyses (Sterne et al., 2011; Whiting et al., 2011).”
Modern methods for diagnosing pressure ulcers: a systematic review of non-invasive technologies
Putilin, D. O., Охлопков, В. А., Хорошилов, С. Е., Kuzovlev, A. N., Boeva, E. A., Юрьевна, К. И., & Спиридонова, Е. А. (2026) · Transplantologiya The Russian Journal of Transplantation · doi:10.23873/2074-0506-2026-18-3-458-472
Tandon, A., Kumar, A., Kantipudi, S. J., Gupta, K., Chatterjee, S., & Kumari, S. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-122674
“27 Therefore, a comprehensive systematic review and meta-analysis is warranted to synthesise the available evidence and provide pooled estimates of diagnostic accuracy for miRNA-based assays in UADT malignancies.”
Letafatkar, N., Jala, S. R. A., Somu, K. P., Lichahi, M. A., Anil, G., Korsapati, H. R., Saeedi, C., Eftekhari, B., Mahapatro, A., Jafari, M., et al. (2026) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-026-01821-0
Magro, G., Laterza, V., Mechelli, A., Tosto, F., Longo, A., Camastra, C., & Quattrone, A. (2026) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2026.126162
Azzam, M., Kawtharany, H., Nazzal, J., Hamarsha, Q., Alkhader, A., Khraise, T., AlMasri, M. M., Zeid, H. K. A., Alwan, I., Jaber, N., et al. (2026) · Blood Advances · doi:10.1182/bloodadvances.2026021240
Adebayo, D. O., England, A., McEntee, P. M., Ryan, D. J., & Maher, M. (2026) · Cureus · doi:10.7759/cureus.115779
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2) checklist [14] was used to assess for ‘risk of bias’ and the ‘applicability’ questions.”
Interpretación de las pruebas diagnósticas en medicina clínica y hepatología
Vizcaíno, G., & Villalobos-Orozco, M. W. (2026) · Hepatología · doi:10.59093/27112330.180
Goyal, A., Merchant, K. S., Deloso, E., Chen, S. G., Abode-Iyamah, K. O., Jones, P. M., Gruenbaum, S. E., & Gruenbaum, B. F. (2026) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000001160
Wang, Y., Song, Z., Hou, Z., Chen, Y., Liu, S., Chen, C., Guan, H., Pang, Z., 沈, 延., Zhang, Z., et al. (2026) · Cancer Medicine · doi:10.1002/cam4.72226
“To evaluate the methodology and the risk of bias, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and the Radiomics Quality Score (RQS) tools were applied [24, 25].”
Diagnostic Accuracy Requires an Independent Reference Standard in Local Allergic Rhinitis
Kaplan, F., & Kaplan, B. K. (2026) · Ear Nose & Throat Journal · doi:10.1177/01455613261488458
Intelligent Bloodstain Pattern Analysis Using Convolutional Neural Networks
Sonia, R., Sharma, M., Saharan, S., & Chandrakar, T. R. (2026) · Cureus Journal of Computer Science. · doi:10.7759/s44389-026-00264-y
Gebremeskele, B. T., Tesfaye, H., Hammeso, W. W., & Churiso, G. (2026) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2026.109101
From Agreement to Replacement: Adjudicating a Discordant Fistula Finding
Duan, G., & Zhang, G. (2026) · Journal of Ultrasound in Medicine · doi:10.1002/jum.70447
Lin, C., Setiawan, F., Hikmahtiyar, S., Lai, P.-C., Kuan, F., Hsu, K., Lin, W., Chen, P.-Y., Huang, M.-T., Lin, C.-J., et al. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.08.048
Mustehsan, M. A., Shehzad, M. M., Abid, A., Viqar, I., & Bashir, M. M. (2026) · Burns · doi:10.1016/j.burns.2026.108212
Meremikwu, K. C., Lee, S., Tang, B., Wilson, M. L., & Killu, K. (2026) · Cureus · doi:10.7759/cureus.115858
Caiazza, C., Fusco, G., Ugga, L., Rossano, F., Toni, C., Cirillo, M., Sampogna, G., & Fiorillo, A. (2026) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-026-02359-y
Taherian, M., Yaghoubyan, S. H., Bagherifard, K., & Malekhosseini, R. (2026) · Journal of Clinical Research in Paramedical Sciences · doi:10.5812/jcrps-173819
Torrejano, L. D. M., Beltrán, M. C. J., & Ortiz, L. A. O. (2026) · Ciencia Latina Revista Científica Multidisciplinar · doi:10.37811/cl_rcm.v10i4.25491
Villamizar, J. A. M., & López, L. M. R. (2026) · Dialnet (Universidad de la Rioja)
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.