QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 14,101–14,200 of 14,770
Dashti, M., Khosraviani, F., Ghadimi, N., Kalantari, S., Amirzade-Iranaq, M. H., Hemmati, G., Arzani, S., Pirayesh, Z., & Motie, P. (2026) · Imaging Science in Dentistry · doi:10.5624/isd.20250325
“13 Complementary guidelines, such as TRIPOD-AI for transparent reporting of prediction models (including AI/machine learning methods) and FUTURE-AI principles, further promote reproducibility and methodological rigor in AI research.”
InfluentialAssessing quality of medical care: modern methods and prospects for improvement
Golubeva, A. V., Kovalenko, A. Y., & Grigoryan, A. G. (2025) · Marine Medicine · doi:10.22328/2413-5747-2025-11-2-28-37
Rizzo, L., Citarella, A. A., Claudio, P. P., Cortese, A., Marco, F. D., Sebillo, M., & Tortora, G. (2026) · Multimedia Tools and Applications · doi:10.1007/s11042-026-21805-6
Wu, G., Yang, F., & Wu, Q. (2026) · Advances in Medical Sciences · doi:10.1016/j.advms.2026.07.003
Zhang, Z., Jiang, Y., Gong, Y., Xie, H., Han, Y., & Chen, P. (2026) · Cancer Medicine · doi:10.1002/cam4.72134
“The revised Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to evaluate diagnostic studies across patient selection, index test, reference standard, and flow/timing domains [24].”
Bousbih, G., & Sawesi, S. (2026) · Lecture notes in networks and systems · doi:10.1007/978-3-032-32636-2_30
Mieles, J. E. B., & Pilozo, J. (2026) · Revista Gregoriana de Ciencias de la Salud. · doi:10.36097/rgcs.v3i2.3234
Kopčinović, L. M., Resta, C. D., Stankovic, S. D., Ladang, A., Chiollaz, A.-C., da Silva, H. F., Sapin, V., Özben, T., & European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) on behalf of the Committee: Biomarkers of Mild Traumatic Brain Injury (2026) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2026.2708643
O’Dwyer, M., Murray, C., Harley, M., John, A., & Matiullah, S. (2026) · Hearts · doi:10.3390/hearts7030023
Rana, R. R., Mehan, N., Hassan, R., Gohil, Y., Tyagi, A., & Maffulli, N. (2026) · British Medical Bulletin · doi:10.1093/bmb/ldag023
Proteomic biomarkers for diagnosis and prognosis in glioblastoma: A systematic review
Ghasemi, F., Gholami, M. A., Mohammadkarimi, V., Sadeghi, E., Vardanjani, H. M., & Ajami, R. (2026) · Journal of Neuro-Oncology Discovery · doi:10.1007/s44499-026-00009-4
“Risk of bias was generally high across all four QUADAS-2 domains: patient selection, index test, reference standard, and flow/timing [ 21 ].”
InfluentialZhang, Q., Zhu, R., Li, Y., Li, H., Liu, L., Hu, Z., & Huo, Y. (2026) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2026.1789013 · Cited by 1
“Risk of bias and applicability concerns were assessed using QUADAS-2 across four domains (patient selection, index test, reference standard, and flow/timing) (Whiting et al., 2011).”
Cine Magnetic Resonance Imaging for Assessing Chest Wall Invasion in Lung Cancer
Ramos, D. D. O. S., Moreira, S. V., da Silva, M. A. M., Fagundes, M. D. C., de Faria, L. L., Paulo, T. D. G., Torri, G. B., Altmayer, S., & Hochhegger, B. (2026) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000902
Frear, C. C., Frear, L., Lambie, D., & Godbolt, A. M. (2026) · Journal of Cutaneous Pathology · doi:10.1111/cup.70185
de Assis, T. S. M., Freire, M. L., Silva, S. N., Avelar, D. D. S., Cota, G., & Rabello, A. (2026) · Revista da Sociedade Brasileira de Medicina Tropical · doi:10.1590/0037-8682-0466-2025
“Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies–2 (QUADAS-2) tool 42 .”
Aguirre-Milachay, E., Valladares-Garrido, M. J., Chapoñan-Agip, N. V., Cahuapaza-Gutierrez, N. L., Torres-Zegarra, B. C., Diaz-Torres, M., León‐Figueroa, D. A., & Runzer-Colmenares, F. M. (2026) · Cancers · doi:10.3390/cancers18152478
“Applicability issues were also assessed [21].”
Shrestha, B., Koju, S., & Shrestha, E. (2026) · Genomics and AI in Personalized Medicine · doi:10.64220/gaipm.v1i1.007
Liu, Q., Gu, S., & Ding, Y. (2026) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-026-01937-w
“Because QUADAS and its revised version, QUADAS-2, were developed specifically for diagnostic-accuracy studies [16, 17], whereas the eligible evidence comprised mainly prevalence, cross-sectional, case-control, cohort, prospective-monitoring, and descriptive epidemiological studies, Joanna Briggs…”
Hsiao, K., Lin, H.-L., & Chen, C. (2026) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.70434
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) framework was thus employed to evaluate the methodological quality of each study included in the meta-analysis [11].”
Fabric-Aware and Physics-Informed Generative AI for Simulation-Ready Garments in Digital Fashion
Lee, Y., Kim, M. K., & Jun, H. (2026) · IEEE Access · doi:10.1109/access.2026.3720444
Arbelaez-Ramirez, A., & Rosas, D. B. (2026) · Diagnostics · doi:10.3390/diagnostics16152468
Guerrero, O. L. C., Fruto, J. Y. G., Vásquez, L. N. A., Estupiñán, M. C. M., & Romero, G. I. T. (2026) · Indian Journal of Musculoskeletal Radiology · doi:10.25259/ijmsr_30_2026
Claustrum Involvement in New Onset Refractory Status Epilepticus: A Systematic Review
Burani, M., Muccioli, L., Giovannini, G., Orlandi, N., Bisulli, F., & Meletti, S. (2026) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.70490
“The risk of bias of the included studies was evaluated using the QUADAS-2 tool [21], evaluating the domains of patient selection, index test, reference standard, and flow and timing.”
Yen, C., Niu, K.-Y., & ZhangJian, S.-J. (2026) · Critical Care Medicine · doi:10.1097/ccm.0000000000007312
Khanagar, S. B., Alfaifi, A. A., Singh, O. G., Alayyash, A., Haq, F. U., Alsomaie, B., Bhat, S., Khinda, V., Vishwanathaiah, S., & Iyer, K. (2026) · Frontiers in Oral Health · doi:10.3389/froh.2026.1895438
“K) independently evaluated the methodological quality and risk of bias of the included studies using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool (30).”
Kim, D. H., Jang, D. W., & Hwang, S. H. (2026) · Clinical Otolaryngology · doi:10.1111/coa.70154
An, X., Geng, J., Lei, K., & Su, B. (2026) · BMC Nephrology · doi:10.1186/s12882-026-05209-0
The use of machine learning models for subdural hematoma detection: a single-arm meta-analysis
Dumasia, S. R., Ahmed, W., Edavettal, M. J., Castellanos, M., Gandhi, O. H., Lanzino, G. S., & Choudhri, O. (2026) · Neurosurgical Review · doi:10.1007/s10143-026-04422-7
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the quality of studies included in our systematic review [ 15].”
Go, A. E. H. C., Schepers, R. H., Wellens, H. L. L., Jansma, J., & Kuijpers-Jagtman, A.-M. (2026) · European Journal of Orthodontics · doi:10.1093/ejo/cjag057
“To assess the risk of bias (RoB) in the included studies, we used the Quality assessment of diagnostic accuracy studies—QUADAS-2 tool [13].”
Cimini, L. A., Klok, F. A., Carrier, M., de Wit, K., Woller, S. C., Rigutini, A. G., Odabashian, R., Talerico, R., Ranalli, M. G., & Becattini, C. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-113000
Foley, J., Hession, E., Umana, E., & Boland, F. (2026) · PLoS ONE · doi:10.1371/journal.pone.0355476
Proximity-extension dementia-panel in 41 brain disorders: a meta-analysisPreprint
Blujdea, E. R., Hok‐A‐Hin, Y. S., Schumacher, A.-M., Maple‐Grødem, J., Cano, A., Ali, M., Price, R., Göteson, A., Abdelhak, A., Sogorb‐Esteve, A., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-9903081/v1
Proteomic profiling of pulpal and periapical diseases: a systematic review
Rai, A. S., Iype, A. M., Bhat, R., & Shetty, P. (2026) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2026.1923261
“The methodological quality and risk of bias of included studies were assessed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool adapted for proteomic biomarker discovery studies (24).”
Raza, A. A., Munir, S., Malik, S., Zafar, S., & Naqvi, S. Z. H. (2026) · Genetics and Molecular Research · doi:10.4238/wr42v238
Lumbar Spine Motion Analysis: A Systematic Review of Segmental and Global Range of Motion
Tan, Q.-Y., Aurangzeb, A., Mohamad, H., Leong, D., Kumar, D., Janssen, M. E., & Chew, Z. (2026) · Cureus · doi:10.7759/cureus.114125
Arriel, R. A., Souza, H. L. R., de Oliveira, G. M., Pereira, M. R., & Marocolo, M. (2026) · International Journal of Sports Science & Coaching · doi:10.1177/17479541261471826
Sowan, B. I., & Massad, B. (2026) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2026.101794
Muhaisen, A. H. M., Assaf, A., Aleidi, M., AL-Natsheh, I., Al-Rabba, F., Qasaymeh, M., AL-Nayef, M., & Alquran, W. Y. (2026) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2026.115354 · Cited by 1
Gadour, E., Miutescu, B. P., Raheem, B., Burciu, C., Saeed, Z. A. A., Sharrofna, A., Gardezi, S. A., Facciorusso, A., & Mahmood, S. (2026) · BMC Gastroenterology · doi:10.1186/s12876-026-05201-w
“…NOS was used as the primary quality appraisal tool because the evidence base included mixed observational and safety-only studies; however, QUADAS-2 would have provided a more diagnostic-test-specific assessment of patient selection, index test, reference standard, and flow/timing domains [10].”
Yu, L., Liu, D., Payne, J. M., Thompson, H. L., Wu, X., Moreira, J. P., Morey, L., Peper, M., Iroff, H., Mujica, B. F., et al. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09698-6
Cuevas‐Budhart, M. Á., Gómez-Rosas, K., Saavedra-Fernández, R. D., Ávila, M., Campos, E. I., Ferreira‐Hermosillo, A., Ramos, A., Cavero‐Redondo, I., & Paniagua, R. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15166137
“The selection process was documented using a PRISMA flow diagram [21]. https://doi.org/10.3390/jcm15166137”
InfluentialSafari, S., Najafi, I., Yousefifard, M., Forouzanfar, M. M., Mazloom, H., & Sharifi, A. (2025) · Journal of Emergency Practice and Trauma · doi:10.34172/jept.2025.15
“The quality of the selected papers’ methods was evaluated using the Quality Assessment of Diagnostic Accuracy Studies Version 2 (QUADAS-2) technique (25).”
Al-Adhami, D. A., Abdlkadir, A. S., Abdlkadir, N. S., Ruzzeh, S., Abdulrahman, M., Mohamad, I., Sheikha, A. A., Shi, H. J., Kairemo, K., & Al‐Ibraheem, A. (2026) · British Journal of Radiology · doi:10.1093/bjr/tqag181
Schwarz, A., Song, M., Wu, M., Sakthi, S., Settle, M., Farahmand, E., Wing, R., Hansen, M., Veerbeek, J. M., & Cramer, S. C. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-02094-4
Mohammadzadeh, S., Mirzai, M., Abdi, A. B., Kiani, I., Moghaddam, H. S., & Radmard, A. R. (2026) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2026.100123
Sharma, S., Ratha, S. K., Paul, R., & Singh, K. (2026) · Adolescencia e Saude · doi:10.67440/ahj.v21i5s.1376
Skaik, K., Abdallah, J. P., Bouchard, M. D., Ayeni, O. R., & Almasri, M. (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70571
Liu, H., & Liu, X. (2026) · Korean Journal of Radiology · doi:10.3348/kjr.2026.0900 · Cited by 1
“Furthermore, 40% of studies were rated as having a high or unclear risk of bias in the QUADAS-2 [3] reference-standard domain, which can be ascribed to the inadequately described blinding between the index test and reference standard, as well as the fact that “pathology plus clinical follow-up”…”
Mudrik, A., Dodge, A., Galindo, A. M., Nadkarni, G. N., Soffer, S., & Klang, E. (2026) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-026-02173-x
Gebremichael, D. A., Zimme, Z. A., Mengesha, L. Y., Jibat, N., Berihun, A. A., Ayele, A. A., Ashenafi, S. A., Tegegn, H. G., & Gete, K. Y. (2026) · Diagnostic and Prognostic Research · doi:10.1186/s41512-026-00235-w
“Two reviewers independently assessed risk of bias and applicability using QUADAS-2 across patient selection, index test, reference standard, and flow/timing domains [15].”
Yoon, J. H., Lee, S., & Zhang, H. (2026) · Korean Journal of Radiology · doi:10.3348/kjr.2026.1104
“We addressed this issue in our risk-of-bias assessment and transparently reported that 40.0% of the included studies had a high or unclear risk of bias in the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) reference standard domain [4].”
InfluentialDiagnostic accuracy of chest computed tomography for community-acquired pneumonia: A meta-analysis
Chen, W., Song, H., Peng, Y., & Dong, P. (2026) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2026.102580
Cevher, Ş. K., & Çankaya, E. (2026) · International Urology and Nephrology · doi:10.1007/s11255-026-05337-4
Lacorte, L. H., Quijencio, W. D., & Lizarondo, L. M. (2026) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzag109
AI-driven autism screening: superiority over traditional methods – systematic review
Aghaie, A., & Nikkhoo, F. (2026) · Current Psychology · doi:10.1007/s12144-026-09891-z
“Risk of bias was assessed with QUADAS-2 (Whiting et al., 2011) for diagnostic accuracy studies and PROBAST (Wolff et al., 2019) for AI prediction models.”
Pitsillidi, A., Vona, L., Kyriakoulis, K., Iliakis, P., Stabile, G., & Noé, G. (2026) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-026-08553-6
Beşiroğlu, H., Erkoç, M., Çakır, S. S., Pazır, Y., & Kadıhasanoğlu, M. (2026) · Therapeutic Advances in Urology · doi:10.1177/17562872261476755
Alanazi, S. K., Alkharisi, M. M., Alshalhoob, H. B., Alduraywish, W. A., Almulla, S. A., Alnajim, L. A., Alanazi, L. N., Almulla, A. A., Alanazi, S. L., & Alfuraih, I. (2026) · Digital Health · doi:10.1177/20552076261478204
Blood levels of PACAP in migraine: A systematic review
Jørgensen, P. L., Al-Khazali, S., Christensen, R. H., Al‐Khazali, H. M., Ashina, M., & Ashina, H. (2026) · Cephalalgia · doi:10.1177/03331024261468031
“Risk of bias across individual studies was assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool, 28 which evaluates four key domains: participant selection, index test integrity, appropriateness of the reference standard, and the timing and fl ow of data collection.”
de Sousa, D. F., Neto, A. C. F., de Oliveira, K. G. L. G., Marques, C. S. M., de Menezes, R. N., Vieira, M. E. N. P., Rocha, R. P. B., Bezerra, L. S. V., Ramos, P. A. T., Carvalho, P. C., et al. (2026) · Editora Humanize eBooks · doi:10.29327/5901805.1-4
Smyth, M. A., Brown, T. P., Fothergill, R. T., Griffiths, F. E., Lall, R., Long, J. L., Petrou, S., Siriwardena, A. N., Slowther, A., Betteley, L., et al. (2026) · Health and Social Care Delivery Research · doi:10.3310/gjgp0922 · Cited by 2
Miró, A., Fernández‐García, R., Carrasco‐Marginet, M., García, F., & Irurtia, A. (2026) · Textile Research Journal · doi:10.1177/00405175261472739
Arslan, A., Dikici, A., Danisman, F., Ünal, Y. C., Yıldırım, Ö. F., & Kaya, Ş. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15166214
The PRIMARY score for clinically significant prostate cancer
Li, L., Xu, G., lin, A., & Zhai, L. (2026) · Asian Journal of Surgery · doi:10.1016/j.asjsur.2026.07.061
Bridging the Diagnostic Gap: Reviewing Current Endometriosis Screening Tools and Models
Kathrada, F., Eyk, A. D. V., & Chauke, L. (2026) · Journal of Women s Health · doi:10.1177/15409996261478005
Application of Outer Membrane Protein Omp25 in Serological Diagnosis of Brucellosis
Zhou, Q., 熊冬琪, Wang, X., Zhu, Q., Dolkun, N., Tuxun, Z., Zhang, Z., Wang, Q., & Xiao, X. (2026) · Infectious Disease Reports · doi:10.3390/idr18040086
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [22] was independently applied by both reviewers to evaluate the risk of bias across four domains (patient selection, index test, reference standard, flow and timing).”
Mohamed, M. I., Khorkhash, A., Mirza, E., Elshaer, M., Raad, H., Meselhi, A., Abdellatif, M., Ahmed, M., El-Feky, M., Abdelglil, M., et al. (2026) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-026-01822-z
“The methodological quality and risk of bias of all included diagnostic accuracy studies were independently evaluated by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [21].”
Køtter, M. F., Schambye, M. E. R., Espensen, S., Pedersen, N. A., Dybdal, D. T. H., Brok, J. S., & Hjalgrim, L. L. (2026) · Cancers · doi:10.3390/cancers18162590
Singh, S. K. C. M., Jayalakshmi, J., Ethel Shiny, S., Nithyamala, I., Mani, S., & Suresh, K. (2026) · Cureus · doi:10.7759/cureus.114379
“Risk of bias was assessed using a review-specific adaptation of Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [8].”
Laryngeal Ultrasound for Vocal Cord Palsy in Adults: A Meta‐Analysis of Diagnostic Studies
Rao, U. S., & Rao, S. C. (2026) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.70054
Okorie, N., Roos, N. A. C., & Nurdin, A. (2026) · African Journal of Urology · doi:10.1186/s12301-026-00605-2
Diagnostic accuracy of objective measures for ocular malingering: A systematic review
Ampiah, E. E., Agyiri, P. E., Owusu, G., Miezah, D., Panyin, R., & Ayandoh, C. E. (2026) · Journal of Optometry · doi:10.1016/j.optom.2026.100621
Contemporary Approaches in Oral and Maxillofacial Imaging and Diagnosis
Eninanç, İ., ATAPEK, M. M., Ova, U. A., Zengin, U., Ketenci, F., Ozsoy, S. C., Erdoğan, B., Ertürk, M., Aslan, F., Mican, M. M., et al. (2026) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.4040
Maietta, J. E., Luongo, D. A., Saperstein, O., & Gaudet, C. E. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09713-w
Sarmadi, S., Zare‐Kaseb, A., Sanaie, N., Zandi, M., & Beigzadeh, S. (2026) · International Journal of Nursing Knowledge · doi:10.1177/20473087261460986
“The methodological quality of the included studies was assessed independently by two reviewers using the QUADAS-2 tool (Whiting et al., 2011), which is speci fi cally designed for evaluating diagnostic accuracy studies.”
Alhazmi, A. M., Alayoubi, F., Mufti, R. E., & Albulushi, A. (2026) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2026.103423
Diagnostic accuracy of passive leg raising test: systematic review and network meta-analysis
Yadgarov, M. Y., Бондоевич, Б. Л., Kuznetsov, I. V., Викторович, Р. П., Yavorovskiy, A. G., Yakovlev, A. A., & Likhvantsev, V. V. (2026) · Patologiya krovoobrashcheniya i kardiokhirurgiya · doi:10.21688/1681-3472-2026-2-33-44
Villanueva-De-Luna, K.-V., Jiménez, L. I. G., Lomelí, J., Antelis, J. M., Mendoza-Montoya, O., Jiménez, B. A. R., & Tovar-Corona, B. (2026) · Sensors · doi:10.3390/s26165121 · Cited by 1
Abedeen, Z. U., Alam, I., Atif, M., & Saleem, S. (2026) · Portal hypertension & cirrhosis · doi:10.1002/poh2.70066
Lau, J., Lim, J., Lee, M., & Tan, K. K. (2026) · Cancer Epidemiology · doi:10.1016/j.canep.2026.103207
Early Detection of Autism in Young Children Using AI and IoT: A Systematic Review Focused on Rwanda
Twesigye, G., Masabo, E., & Bamurigire, P. (2026) · African Journal Of Applied Research · doi:10.26437/v6cf3x32
Estado de arte sobre aplicaciones y avances en tecnologías eNose utilizando mapeo sistemático
Pacheco, D. A. C. (2026) · Universidad Politécnica Salesiana Repositorio Digital (Universidad Politécnica Salesiana)
Abedin, F., Das, M., Bishayi, A., Saha, P., Husna, A., Haque, S., Rana, S. S., Sudesh, R., & Ahmad, F. (2026) · Archives of Women s Mental Health · doi:10.1007/s00737-026-01753-8
“Publication quality and risk of bias of the included stud - ies were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (Whiting et al. 2011).”
Is IOTA simple rules superior to RMI 1 for ovarian tumor diagnosis? A systematic review.
Kumari, R., Iqbal, D. S., Gupta, S., & Vijya (2026) · SJ Gynecology and Obstetrics Africa · doi:10.51168/wgc0ds79
Ohannesian, V. A., Ishizuka, B. M., Menezes, I. R., Falcão, L., Schmitt, L. G., Mariussi, M., Cabral, M., Vaqueiro, H. B., Vicente, G. N., Jabour, V. A., et al. (2026) · Ultrasound · doi:10.1177/1742271x261472364
Role of CXCR4 PET Imaging for the Evaluation of Gliomas: A Comprehensive Literature Review
Dondi, F., Bellini, P., Cossandi, M., Rinaldi, R., Camoni, L., Tomasoni, F., Statuto, M., Viganò, G. L., & Bertagna, F. (2026) · Cancers · doi:10.3390/cancers18162657
“The quality assessment of these studies, including the risk of bias and applicability concerns, was carried out using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) evaluation [76].”
Guo, X., Peng, Y., & Ji, W. (2026) · World Journal of Urology · doi:10.1007/s00345-026-06693-7
Deep Learning for the Assessment of Alveolar Bone Loss on Intraoral Radiographs: A Systematic Review
Hashim, N. T., Gismalla, B. G., Rahman, M. M., Mohammed, R., Padmanabhan, V., Islam, M. S., Babiker, R. A., Elsheikh, M., Ahmed, A., & Kukreja, B. J. (2026) · Diagnostics · doi:10.3390/diagnostics16162575 · Cited by 1
“Risk of bias was assessed independently in duplicate using the Quality Assessment of Diagnostic Accuracy Studies–2 (QUADAS-2) tool [40], tailored to arti fi cial intelligence diagnostic studies by the addition of signalling questions addressing (i) whether the test set was independent of the…”
CircRNAs as biomarkers for osteoporosis: a systematic review and meta-analysis
Li, X., Wang, J., Wang, X., Guo, S., Liu, S., Liu, R., Liang, H., & Wang, S. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1768245 · Cited by 1
“The methodological quality and risk of bias of the included studies were assessed independently by two investigators using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (31).”
Batson, S., Lombardo, S., Leeflang, M., Taylor‐Phillips, S., & Marshall, J. (2026) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2026.112471
Self-citationTan, C., Wang, B., He, S., Gong, Y., Zhang, L., Wang, H., Tang, Q., Li, X., Xiong, G., Zhou, L., et al. (2026) · medRxiv · doi:10.64898/2026.08.17.26360042
Walser, A., Bitos, K., Giannopoulos, A. A., Pazhenkottil, A. P., Treyer, V., Huellner, M. W., Buechel, R. R., Kaufmann, P. A., & Benz, D. C. (2026) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyag141
Dao, D. H., Phetcharaburanin, J., Sukon, P., & Thamrongyoswittayakul, C. (2026) · Research in Veterinary Science · doi:10.1016/j.rvsc.2026.106368
Gupta, P. S., Akintomide, M., Ramos, M. D., Sterling, E., Chakravarty, S., & Sakib, M. N. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100696
salazar, I., Thomas, G., Doyle, M. A., Wilde, K., Al-Shawwa, A., Chohan, S. S., Khan, W., Zahra, F., Modi, L., Sommerfeldt, M. F., et al. (2026) · doi:10.2196/preprints.108967
Gold Coast criteria for ALS diagnosis: individual participant data meta-analysis
Shrestha, N., Munn, Z., Calma, A. D., Pavey, N., Tsuji, Y., Menon, P., Padovani, A., Risi, B., Ferullo, L., Filosto, M., et al. (2026) · Journal of Neurology · doi:10.1007/s00415-026-14046-y
“Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies; QUADAS-2 [30] and QUA-DAS-C [31] tools in the included studies using publication and information provided by study authors.”
Abdullah, M. W. (2026) · Acta Neurologica Belgica · doi:10.1007/s13760-026-03176-9
Su, J., 迟常亮, Wang, S., Bian, G., Xing, D., Zhang, M., Chang, M., Yin, J., & Wang, X. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1777128
Riancho‐Zarrabeitia, L., & Riancho, J. A. (2026) · Rheumatology · doi:10.1093/rheumatology/keag434
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.