Cited by 135Hearing, Cochlea, Tinnitus, GeneticsHearing Loss and RehabilitationNoise Effects and Management

Sound therapy (using amplification devices and/or sound generators) for tinnitus.

Open access
Sereda, Magdalena, Xia, Jun, El Refaie, Amr, Hall, Deborah A, Hoare, Derek J·2018·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Tinnitus affects 10% to 15% of the adult population, with about 20% of these experiencing symptoms that negatively affect quality of life. In England alone there are an estimated ¾ million general practice consultations every year where the primary complaint is tinnitus, equating to a major burden on healthcare services. Clinical management strategies include education and advice, relaxation therapy, tinnitus retraining therapy (TRT), cognitive behavioural therapy (CBT), sound enrichment using ear-level sound generators or hearing aids, and drug therapies to manage co-morbid symptoms such as insomnia, anxiety or depression. Hearing aids, sound generators and combination devices (amplification and sound generation within one device) are a component of many tinnitus management programmes and together with information and advice are a first line of management in audiology departments for someone who has tinnitus. OBJECTIVES: To assess the effects of sound therapy (using amplification devices and/or sound generators) for tinnitus in adults. SEARCH METHODS: The Cochrane ENT Information Specialist searched the Cochrane ENT Register; Central Register of Controlled Trials (CENTRAL, via the Cochrane Register of Studies); Ovid MEDLINE; Ovid Embase; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 23 July 2018. SELECTION CRITERIA: Randomised controlled trials (RCTs) recruiting adults with acute or chronic subjective idiopathic tinnitus. We included studies where the intervention involved hearing aids, sound generators or combination hearing aids and compared them to waiting list control, placebo or education/information only with no device. We also included studies comparing hearing aids to sound generators, combination hearing aids to hearing aids, and combination hearing aids to sound generators. DATA COLLECTION AND ANALYSIS: We used the standard methodological procedures expected by Cochrane. Our primary outcomes were tinnitus symptom severity as measured as a global score on multi-item tinnitus questionnaire and significant adverse effects as indicated by an increase in self-reported tinnitus loudness. Our secondary outcomes were depressive symptoms, symptoms of generalised anxiety, health-related quality of life and adverse effects associated with wearing the device such as pain, discomfort, tenderness or skin irritation, or ear infections. We used GRADE to assess the quality of evidence for each outcome; this is indicated in italics. MAIN RESULTS: This review included eight studies (with a total of 590 participants). Seven studies investigated the effects of hearing aids, four combination hearing aids and three sound generators. Seven studies were parallel-group RCTs and one had a cross-over design. In general, risk of bias was unclear due to lack of detail about sequence generation and allocation concealment. There was also little or no use of blinding.No data for our outcomes were available for any of our three main comparisons (comparing hearing aids, sound generators and combination devices with a waiting list control group, placebo or education/information only). Data for our additional comparisons (comparing these devices with each other) were also few, with limited potential for data pooling.Hearing aid only versus sound generator device onlyOne study compared patients fitted with sound generators versus those fitted with hearing aids and found no difference between them in their effects on our primary outcome, tinnitus symptom severity measured with the Tinnitus Handicap Inventory (THI) at 3, 6 or 12 months (low-quality evidence). The use of both types of device was associated with a clinically significant reduction in tinnitus symptom severity.Combination hearing aid versus hearing aid onlyThree studies compared combination hearing aids with hearing aids and measured tinnitus symptom severity using the THI or Tinnitus Functional Index. When we pooled the data we found no difference between them (standardised mean difference -0.15, 95% confidence interval -0.52 to 0.22; three studies; 114 participants) (low-quality evidence). The use of both types of device was again associated with a clinically significant reduction in tinnitus symptom severity.Adverse effects were not assessed in any of the included studies.None of the studies measured the secondary outcomes of depressive symptoms or depression, anxiety symptoms or generalised anxiety, or health-related quality of life as measured by a validated instrument, nor the newly developed core outcomes tinnitus intrusiveness, ability to ignore, concentration, quality of sleep and sense of control. AUTHORS' CONCLUSIONS: There is no evidence to support the superiority of sound therapy for tinnitus over waiting list control, placebo or education/information with no device. There is insufficient evidence to support the superiority or inferiority of any of the sound

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd013094.pub2

Cites

135 of 135 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • There is a lack of reliable and consistent evidence on the efficacy of individual and combination tinnitus treatments.

    “There is a lack of reliable and consistent evidence on the efficacy of the individual and combination treatments, such as audiological care and psychological treatment.”

    From Combining the unequal variance signal detection model with the health belief model to optimize shared decision making in tinnitus patients: part 2—patient profiling (2025) · cites this paper as Sereda et al., 2018

    The Authors’ conclusions (Background; page unavailable) find low-quality evidence and insufficient evidence to compare hearing aids, sound generators, and combination devices. The review concerns sound therapy, however, and does not establish a lack of reliable evidence for psychological treatment or for audiological care and psychological treatment combined. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • The lack of reliable and consistent evidence on tinnitus treatment efficacy is due to different study designs and lack of reproducible results.

    “This is due to different study designs and lack of reproducible results (Fuller et al., 2020; Hoare et al., 2014; Sereda et al., 2018).”

    From Combining the unequal variance signal detection model with the health belief model to optimize shared decision making in tinnitus patients: part 2—patient profiling (2025) · cites this paper as Sereda et al., 2018

    The Discussion (page unavailable) says evidence for the effectiveness of sound therapy is lacking, and identifies study limitations including risk of bias and imprecision. It does not attribute that gap to a lack of reproducible results; the Methods (page unavailable) instead describes three pooled studies as having similar, non-significant effect estimates. The review also concerns sound therapy specifically, rather than tinnitus treatments generally. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 15

  1. Baguley D, McFerran D, Hall D. Tinnitus. Lancet 2013;382(9904):1600‐7. [PUBMED: 23827090] [DOI] [PubMed] [Google Scholar]
  2. Beck AT, Steer RA, Brown GK. Manual for the Beck Depression Inventory‐II. San Antonio, TX: Psychological Corporation, 1996. [Google Scholar]
  3. Department of Health. Provision of Services for Adults with Tinnitus. A Good Practice Guide. London: Central Office of Information, 2009. [Google Scholar]
  4. Hallam RS. Manual of the Tinnitus Questionnaire (TQ). London: The Psychological Corporation, Brace & Co, 1996. [Google Scholar]
  5. Henry JA, Zaugg TL, Myers PM, Kendall CJ. Progressive Tinnitus Management: Counseling Guide. San Diego, CA: Plural Publishing, 2010. [Google Scholar]
  6. Hoare DJ, Searchfield GD, Refaie A, Henry JA. Sound therapy for tinnitus management: practicable options. Journal of the American Academy of Audiology 2014;25:62‐75. [DOI] [PubMed] [Google Scholar]
  7. McFerran D. Tinnitus and hyperacusis. In: Graham JM, Baguley DM editor(s). Ballantyne's Deafness. Chichester, UK: Wiley‐Blackwell, 2009:175‐88. [Google Scholar]
  8. The Nordic Cochrane Centre, The Cochrane Collaboration. Review Manager (RevMan). Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014.
  9. Roberts LE, Eggermont JJ, Caspary DM, Shore SE, Melcher JR, Kaltenbach JA. Ringing ears: the neuroscience of tinnitus. Journal of Neuroscience 2010;30(45):14972‐9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Sanchez TG, Ferrari GMS. The control of tinnitus through hearing aids: suggestions for optimal use. Pró‐Fono Rev Atualização Cient 2002;14:111‐8. [Google Scholar]
  11. Sweetow RW, Levy MC. Tinnitus severity scaling for diagnostic/therapeutic usage. Hearing Instruments 1990;41:20‐1. [Google Scholar]
  12. Sweetow RW, Fehl M, Ramos PM. Do tinnitus patients continue to use amplification and sound therapy post habilitation?. Hearing Review 2015;19:20‐7. [Google Scholar]
  13. Vernon J, Silverstein H, Norrell H. The use of masking for relief of tinnitus. Neurological Surgery of the Ear 1976;2:104‐18. [Google Scholar]
  14. Vernon JA. Attempts to relieve tinnitus. Journal of the American Audiology Society 1977;2:124‐31. [PubMed] [Google Scholar]
  15. Vernon JA, Meikle MB. Tinnitus masking. Tinnitus Handbook. San Diego: Singular, 2000:313‐56. [Google Scholar]

Cited by

Sorted by citations

Authors
Sereda, M., Xia, J., El Refaie, A., Hall, D. A., & Hoare, D. J.
Affiliations
  • University of Nottingham (GB)
  • University College Cork; Department of Speech and Hearing Sciences; Cork Ireland
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2018-12-27
Volume
2018
Issue
12
Pages
CD013094-CD013094
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2908315352
Cited by
135
References
135
Citations by year
2026: 4 · 2025: 12 · 2024: 16 · 2023: 25 · 2022: 23 · 2021: 23 · 2020: 17 · 2019: 7 · 2018: 3 · 2017: 4 · 2016: 1
FWCI
2.32
Type
journal article
Language
en
Open access
Locations
  • Cochrane Database of Systematic Reviews (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
  • Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
  • Cork Open Research Archive (University College Cork, Ireland) (submittedVersion)
Funders
  • U.S. Department of Veterans Affairs (C9230-C)
  • Stiftelsen Tysta Skolan
  • Riksbankens Jubileumsfond
  • Oticon Fonden
Topics
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Hearing Loss and Rehabilitation
  • Health Sciences › Health Professions › Speech and Hearing › Noise Effects and Management
Keywords
tinnitus, sound therapy, hearing aids, sound generator, tinnitus management, tinnitus loudness, health-related quality of life, depressive symptoms, generalized anxiety disorder, adverse effects, adults, tinnitus retraining therapy, cognitive behavioral therapy, relaxation training, information and advice, ear infection, skin irritation
MeSH terms
Acoustic Stimulation, Adult, Hearing Aids, Humans, Sound, Tinnitus, Randomized Controlled Trials as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review