Flexible Pressure Sensors for Objective Assessment of Motor Disorders
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Monitoring body motion is relevant to motor control disorders as well as assessment of fine motor skills in child development. Furthermore, motion tracking is necessary for rehabilitation monitoring and injury prevention and benefits both sick and healthy individuals. Flexible pressure sensors based on resistors, capacitors, inductors, or transistors are reviewed in the context of healthcare measurements, ranging from physiological signals to body movement characteristics such as grip and gait. To demonstrate the use of flexible pressure sensors for motor assessment, a touch sensing glove that evaluates fine motor skills in autism research is developed. The results show that autistic children perform fewer taps per minute compared to typically developing children, with larger variations in tap durations. In a second example, a force and motion sensing glove is developed to assess spasticity, a neuromuscular disorder that causes muscle stiffness/resistance and jerky movement. Analyses of force versus velocity show movement‐dependent muscle resistance in a patient with spasticity. Through these flexible sensor systems, the shift from subjective scores to objective measurement will promote better diagnosis and dramatically improve the accuracy in tracking patient response to therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Learning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162
A skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Self-citationBinodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Yang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Movement analysis in infancy may be useful for early diagnosis of autism
Teitelbaum, P., Teitelbaum, O., Nye, J., Fryman, J., & Maurer, R. G. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13982 · Cited by 713
Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
Shintake, J., Piskarev, Y., Jeong, S. H., & Floreano, D. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700284 · Cited by 332
Exploring the Role of Wearable Technology in Sport Kinematics and Kinetics: A Systematic Review
Adesida, Y., Papi, E., & McGregor, A. H. (2019) · Sensors · doi:10.3390/s19071597 · Cited by 288
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
Pan, C.-Y., Chu, C.-H., Tsai, C.-L., Sung, M.-C., Huang, C.-Y., & Ma, W.-Y. (2017) · Autism · doi:10.1177/1362361316633562 · Cited by 275
Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
Chen, G.-Z., Chan, I.-S., & Lam, D. C. C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.08.029 · Cited by 133
Point-of-use robotic sensors for simultaneous pressure detection and chemical analysis
Amit, M., Mishra, R. K., Hoang, Q., Galan, A. M., Wang, J., & Ng, T. N. (2019) · Materials Horizons · doi:10.1039/c8mh01412d · Cited by 57
Self-citation
Cited by
Wang, S., Fang, Y., He, H., Zhang, L., Li, C., & Ouyang, J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007495 · Cited by 299
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Guo, Y., Wei, X., Gao, S., Yue, W., Li, Y., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104288 · Cited by 279
Flexible capacitive pressure sensors for wearable electronics
Wang, H., Li, Z., Liu, Z., Fu, J., Shan, T., Yang, X., Lei, Q., Yang, Y., & Li, D. (2022) · Journal of Materials Chemistry C · doi:10.1039/d1tc05304c · Cited by 263
Toward an AI Era: Advances in Electronic Skins
Fu, X., Cheng, W., Wan, G., Yang, Z., & Tee, B. C. K. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00049 · Cited by 172
Metadata
- Authors
- Amit, M., Chukoskie, L., Skalsky, A. J., Garudadri, H., & Ng, T. N.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-11-06
- Volume
- 30
- Issue
- 20
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2983524798
- Cited by
- 129
- References
- 20
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.