Efficient Skin Temperature Sensor and Stable Gel‐Less Sticky ECG Sensor for a Wearable Flexible Healthcare Patch
Abstract
Wearable, flexible healthcare devices, which can monitor health data to predict and diagnose disease in advance, benefit society. Toward this future, various flexible and stretchable sensors as well as other components are demonstrated by arranging materials, structures, and processes. Although there are many sensor demonstrations, the fundamental characteristics such as the dependence of a temperature sensor on film thickness and the impact of adhesive for an electrocardiogram (ECG) sensor are yet to be explored in detail. In this study, the effect of film thickness for skin temperature measurements, adhesive force, and reliability of gel‐less ECG sensors as well as an integrated real‐time demonstration is reported. Depending on the ambient conditions, film thickness strongly affects the precision of skin temperature measurements, resulting in a thin flexible film suitable for a temperature sensor in wearable device applications. Furthermore, by arranging the material composition, stable gel‐less sticky ECG electrodes are realized. Finally, real‐time simultaneous skin temperature and ECG signal recordings are demonstrated by attaching an optimized device onto a volunteer's chest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
The biocompatibility of carbon nanotubes
Smart, S. K., Cassady, A. I., Lu, G. Q., & Martin, D. J. (2006) · Carbon · doi:10.1016/j.carbon.2005.10.011 · Cited by 1,011
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Honda, W., Harada, S., Arie, T., Akita, S., & Takei, K. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303874 · Cited by 456
Self-citationCNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A., Sheng, X., Liu, Y., Lee, J. W., Jang, K.-I., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 403
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L.-C., Ota, H., Wu, E., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 391
Printed multifunctional flexible device with an integrated motion sensor for health care monitoring
Yamamoto, Y., Harada, S., Yamamoto, D., Honda, W., Arie, T., Akita, S., & Takei, K. (2016) · Science Advances · doi:10.1126/sciadv.1601473 · Cited by 386
Self-citationUltraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
Nakata, S., Arie, T., Akita, S., & Takei, K. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00047 · Cited by 379
Self-citationToward Flexible and Wearable Human‐Interactive Health‐Monitoring Devices
Takei, K., Honda, W., Harada, S., Arie, T., & Akita, S. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400546 · Cited by 371
Self-citationPDMS‐Based Elastomer Tuned Soft, Stretchable, and Sticky for Epidermal Electronics
Jeong, S. H., Zhang, S., Hjort, K., Hilborn, J., & Wu, Z. (2016) · Advanced Materials · doi:10.1002/adma.201505372 · Cited by 363
Capacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 239
Cephalopod‐Inspired Miniaturized Suction Cups for Smart Medical Skin
Choi, M. K., Park, O. K., Choi, C., Qiao, S., Ghaffari, R., Kim, J., Lee, D. J., Kim, M., Hyun, W., Kim, S. J., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500285 · Cited by 209
Kanao, K., Harada, S., Yamamoto, Y., Honda, W., Arie, T., Akita, S., & Takei, K. (2015) · RSC Advances · doi:10.1039/c5ra03110a · Cited by 148
Self-citationFully Printed Electrodes on Stretchable Textiles for Long‐Term Electrophysiology
Bihar, E., Roberts, T., Ismailova, E., Saadaoui, M., Işık, M., Sanchez‐Sanchez, A., Mecerreyes, D., Hervé, T., Graaf, J. B. D., & Malliaras, G. G. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201600251 · Cited by 114
Roll to roll processing of ultraconformable conducting polymer nanosheets
Zucca, A., Yamagishi, K., Fujie, T., Takeoka, S., Mattoli, V., & Greco, F. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00750j · Cited by 89
Mohan, A. M. V., Kim, N.-H., Gu, Y. Q., Bandodkar, A. J., You, J., Kumar, R., Kurniawan, J. F., Xu, S. H., & Wang, J. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201600284 · Cited by 87
Koh, A., Gutbrod, S. R., Meyers, J. D., Lü, C., Webb, R. C., Shin, G., Li, Y., Kang, S., Huang, Y. Y., Efimov, I. R., et al. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500451 · Cited by 62
Highly Sensitive Flexible Printed Accelerometer System for Monitoring Vital Signs
Zhang, Y., & Kim, W. S. (2014) · Soft Robotics · doi:10.1089/soro.2014.0003 · Cited by 24
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Muscle-Inspired Self-Healing Hydrogels for Strain and Temperature Sensor
Ge, G., Lu, Y., Qu, X., Zhao, W., Ren, Y., Wang, W., Wang, Q., Huang, W., & Dong, X. (2020) · ACS Nano · doi:10.1021/acsnano.9b07874 · Cited by 732
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Multifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
Self-citation
Metadata
- Authors
- Yamamoto, Y., Yamamoto, D., Takada, M., Naito, H., Arie, T., Akita, S., & Takei, K.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-06-29
- Volume
- 6
- Issue
- 17
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2728337827
- Cited by
- 282
- References
- 30
- FWCI
- 10.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.