Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Open accessAbstract
Implantable technologies are becoming more widespread for biomedical applications that include physical identification, health diagnosis, monitoring, recording, and treatment of human physiological traits. However, energy harvesting and power generation beneath the human tissue are still a major challenge. In this regard, self‐powered implantable devices that scavenge energy from the human body are attractive for long‐term monitoring of human physiological traits. Thanks to advancements in material science and nanotechnology, energy harvesting techniques that rely on piezoelectricity, thermoelectricity, biofuel, and radio frequency power transfer are emerging. However, all these techniques suffer from limitations that include low power output, bulky size, or low efficiency. Photovoltaic (PV) energy conversion is one of the most promising candidates for implantable applications due to their higher‐power conversion efficiencies and small footprint. Herein, the latest implantable energy harvesting technologies are surveyed. A comparison between the different state‐of‐the‐art power harvesting methods is also provided. Finally, recommendations are provided regarding the feasibility of PV cells as an in vivo energy harvester, with an emphasis on skin penetration, fabrication, encapsulation, durability, biocompatibility, and power management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Anatomy and Physiology of the Skin
Kolarsick, P. A. J., Kolarsick, M. A., & Goodwin, C. (2011) · Journal of the Dermatology Nurses' Association · doi:10.1097/jdn.0b013e3182274a98 · Cited by 578
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
A very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Ultralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Shi, Q., Wang, T., & Lee, C. (2016) · Scientific Reports · doi:10.1038/srep24946 · Cited by 210
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Cited by
Solar energy harvesting technologies for PV self-powered applications: A comprehensive review
Hao, D., Qi, L., Tairab, A. M., Ahmed, A., Azam, A., Luo, D., Pan, Y., Zhang, Z., & Yan, J. (2022) · Renewable Energy · doi:10.1016/j.renene.2022.02.066 · Cited by 383
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Metadata
- Authors
- Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2020-07-29
- Volume
- 9
- Issue
- 17
- Pages
- e2000779-e2000779
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3089110658
- Cited by
- 218
- References
- 15
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.