The DOI matches its Crossref record; 88 of the 89 references it cites were found in a registry or an index.
Wireless Power Delivery Techniques for Miniature Implantable Bioelectronics
Open accessAbstract
Progress in implanted bioelectronic technology offers the opportunity to develop more effective tools for personalized electronic medicine. While there are numerous clinical and pre‐clinical applications for these devices, power delivery to these systems can be challenging. Wireless battery‐free devices offer advantages such as a smaller and lighter device footprint and reduced failures and infections by eliminating lead wires. However, with the development of wireless technologies, there are fundamental tradeoffs between five essential factors: power, miniaturization, depth, alignment tolerance, and transmitter distance, while still allowing devices to work within safety limits. These tradeoffs mean that multiple forms of wireless power transfer are necessary for different devices to best meet the needs for a given biological target. Here six different types of wireless power transfer technologies used in bioelectronic implants—inductive coupling, radio frequency, mid‐field, ultrasound, magnetoelectrics, and light—are reviewed in context of the five tradeoffs listed above. This core group of wireless power modalities is then used to suggest possible future bioelectronic technologies and their biological applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Radio Frequency (RF) technology employs far-field electromagnetic waves in the MHz and GHz range to wirelessly transmit energy and data over greater distances to brain implants differentiating it from the near-field magnetic fields utilized in inductive coupling and the intermediate-range operations of Midfield Transfer (MDF).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Singer and Robinson, 2021
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To tackle the issue of alignment sensitivity, there is a push toward the development of ‘smart’ MDF systems equipped with real-time alignment correction capabilities (Singer and Robinson, 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Singer and Robinson, 2021
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Inductive coupling requires relatively short distances between the transmitter and receiver for optimal power transfer (Singer and Robinson, 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Singer and Robinson, 2021
The cited source says what the claim attributes to it.
In the citing paper
“An external transmitter generates these waves, captured by an antenna connected to an internal receiver in the implant, where it is converted to electrical power (Chow et al., 2013; Singer and Robinson, 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Singer and Robinson, 2021
The cited source says what the claim attributes to it.
In the citing paper
“To mitigate these losses, wireless systems might need increased power output, but this is constrained by safety regulations to avoid excessive heat or electromagnetic field exposure, ultimately affecting the maximum usable power for the implant (Singer and Robinson, 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Singer and Robinson, 2021
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olds, J., & Milner, P. (1954) · Journal of Comparative and Physiological Psychology · doi:10.1037/h0058775 · Cited by 3,176
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Piezoelectric Sensors and Sensor Materials
Tressler, J. F., Alkoy, S., & Newnham, R. E. (1998) · Journal of Electroceramics · doi:10.1023/a:1009926623551 · Cited by 716
(2004) · PubMed · Cited by 681
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Ouyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z. Y., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 659
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Wan, C., & Bowen, C. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta09590a · Cited by 591
Enhanced recognition memory following vagus nerve stimulation in human subjects
Clark, K., Naritoku, D., Smith, D. C., Browning, R., & Jensen, R. A. (1999) · Nature Neuroscience · doi:10.1038/4600 · Cited by 575
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
A non-invasive method for focusing ultrasound through the human skull
Clement, G. T., & Hynynen, K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/301 · Cited by 511
Acoustically actuated ultra-compact NEMS magnetoelectric antennas
Nan, T., Lin, H., Gao, Y., Matyushov, A. D., Yu, G., Chen, H., Sun, N., Wei, S., Wang, Z., Li, M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00343-8 · Cited by 487
Han, M., Wang, H., Yang, Y., Liang, C., Bai, W., Yan, Z., Li, H., Xue, Y., Wang, X., Akar, B., et al. (2019) · Nature Electronics · doi:10.1038/s41928-018-0189-7 · Cited by 472
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Bandodkar, A. J., You, J., Kim, N.-H., Gu, Y. Q., Kumar, R., Mohan, A. M. V., Kurniawan, J. F., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 422
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 392
Rat navigation guided by remote control
Talwar, S. K., Xu, S., Hawley, E. S., Weiss, S. A., Moxon, K. A., & Chapin, J. K. (2002) · Nature · doi:10.1038/417037a · Cited by 372
Deep brain stimulation for Parkinson's disease: disrupting the disruption.
Lozano, A., Dostrovsky, J., Chen, R., & Ashby, P. (2002) · Lancet Neurology · doi:10.1016/s1474-4422(02)00101-1 · Cited by 364
Spinal cord stimulation for chronic, intractable pain: Superiority of “multi-channel” devices
North, R. B., Ewend, M. G., Lawton, M. T., & Piantadosi, S. (1991) · Pain · doi:10.1016/0304-3959(91)90125-h · Cited by 350
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 340
Retrospective Review of 707 Cases of Spinal Cord Stimulation: Indications and Complications
Mekhail, N. A., Mathews, M., Nageeb, F., Guirguis, M. N., Mekhail, M. N., & Cheng, J. (2010) · Pain Practice · doi:10.1111/j.1533-2500.2010.00407.x · Cited by 331
Batteries used to power implantable biomedical devices
Bock, D. C., Marschilok, A. C., Takeuchi, K. J., & Takeuchi, E. S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.057 · Cited by 319
Cardiac Pacemakers: Function, Troubleshooting, and Management
Mulpuru, S. K., Madhavan, M., McLeod, C. J., Cha, Y., & Friedman, P. A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.061 · Cited by 302
High-efficiency super-elastic liquid metal based triboelectric fibers and textiles
Dong, C., Leber, A., Gupta, T. D., Chandran, R., Volpi, M., Qu, Y., Nguyen-Dang, T., Bartolomei, N., Yan, W., & Sorin, F. (2020) · Nature Communications · doi:10.1038/s41467-020-17345-8 · Cited by 292
A review of spinal cord stimulation systems for chronic pain
Sinclair, C., Verrills, P., & Barnard, A. (2016) · Journal of Pain Research · doi:10.2147/jpr.s108884 · Cited by 256
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
Wu, X., Zhu, X., Chong, P., Liu, J., Andre, L. N., Ong, K. S., Brinson, K., Mahdi, A. I., Li, J., Fenno, L. E., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1914387116 · Cited by 227
Design and Safety Considerations of an Implantable Rectenna for Far-Field Wireless Power Transfer
Liu, C.-R., Guo, Y.-X., Sun, H.-C., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2352363 · Cited by 222
Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M. K., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 219
Caruana, F., Jezzini, A., Sbriscia-Fioretti, B., Rizzolatti, G., & D, V. G. M. (2011) · Current Biology · doi:10.1016/j.cub.2010.12.042 · Cited by 205
Magnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
Singer, A., Dutta, S., Lewis, E., Chen, Z., Chen, J. C., Verma, N., Avants, B., Feldman, A. K., O’Malley, J., Beierlein, M., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.05.019 · Cited by 202
Self-citationComparison of PZN-PT, PMN-PT single crystals and PZT ceramic for vibration energy harvesting
Yang, Z., & Zu, J. W.-Z. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.05.085 · Cited by 194
Medical and non-medical protection standards for ultrasound and infrasound
Duck, F. A. (2006) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.008 · Cited by 190
Feasibility and Safety of Vagal Stimulation In Monkey Model
Lockard, J. S., Congdon, W. C., & DuCharme, L. L. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05844.x · Cited by 189
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y., Yen, S.-C., & Thakor, N. V. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 189
Conformal phased surfaces for wireless powering of bioelectronic microdevices
Agrawal, D. R., Tanabe, Y., Weng, D., Ma, A., Hsu, S., Liao, S.-Y., Zhen, Z., Zhu, Z., Sun, C., Dong, Z., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0043 · Cited by 180
Wong, A. C. W., Dawkins, M., Devita, G., Kasparidis, N., Katsiamis, A. G., King, O., Lauria, F., Schiff, J., & Burdett, A. J. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221215 · Cited by 172
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Photovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G. A., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 142
Stretchable multichannel antennas in soft wireless optoelectronic implants for optogenetics
Park, S. I., Shin, G., McCall, J. G., Al-Hasani, R., Norris, A., Xia, L., Brenner, D. S., Noh, K. N., Bang, S. Y., Bhatti, D. L., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1611769113 · Cited by 135
Burton, A., Obaid, S. N., Vázquez‐Guardado, A., Schmit, M. B., Stuart, T., Cai, L., Chen, Z., Kandela, I. K., Haney, C. R., Waters, E. A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1920073117 · Cited by 134
Application of a sub–0.1-mm 3 implantable mote for in vivo real-time wireless temperature sensing
Shi, C., Andino-Pavlovsky, V., Lee, S. A., Costa, T. L., Elloian, J. M., Konofagou, E. E., & Shepard, K. L. (2021) · Science Advances · doi:10.1126/sciadv.abf6312 · Cited by 119
Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays
Zhao, Z., Li, X., He, F., Wei, X., Lin, S. Q., & Xie, C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab05b6 · Cited by 107
Large Genetic Animal Models of Huntington's Disease
Morton, A. J., & Howland, D. (2013) · Journal of Huntington s Disease · doi:10.3233/jhd-130050 · Cited by 103
The future of lithium and lithium-ion batteries in implantable medical devices
Schmidt, C., & Skarstad, P. M. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00648-6 · Cited by 101
Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., & for the collaborative study group (2013) · Europace · doi:10.1093/europace/eut124 · Cited by 94
Complications of Spinal Cord Stimulation: Identification, Treatment, and Prevention
Deer, T. R., & Stewart, C. D. (2008) · Pain Medicine · doi:10.1111/j.1526-4637.2008.00444.x · Cited by 91
Compact helical antenna for smart implant applications
Karnaushenko, D. D., Karnaushenko, D., Makarov, D., & Schmidt, O. G. (2015) · NPG Asia Materials · doi:10.1038/am.2015.53 · Cited by 87
Microscopic sensors using optical wireless integrated circuits
Cortese, A. J., Smart, C. L., Wang, T., Reynolds, M. F., Norris, S. L., Ji, Y., Lee, S., Mok, A. T. Y., Wu, C., Xia, F., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1919677117 · Cited by 81
The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System
Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanaćević, M., Thakor, N. V., & Etienne‐Cummings, R. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2802443 · Cited by 77
A Sub-millimeter, Inductively Powered Neural Stimulator
Freeman, D. K., O'Brien, J. M., Kumar, P., Daniels, B., Irion, R. A., Shraytah, L., Ingersoll, B. K., Magyar, A. P., Czarnecki, A., Wheeler, J. J., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00659 · Cited by 74
MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant
Yu, Z., Chen, J. C., Alrashdan, F. T., Avants, B. W., He, Y., Singer, A., Robinson, J. T., & Yang, K. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3037862 · Cited by 72
Self-citationWireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model
Abid, A., O’Brien, J. M., Bensel, T., Cleveland, C., Booth, L., Smith, B. R., Langer, R., & Traverso, G. (2017) · Scientific Reports · doi:10.1038/srep46745 · Cited by 65
1 mm3-sized optical neural stimulator based on CMOS integrated photovoltaic power receiver
Tokuda, T., Ishizu, T., Nattakarn, W., Haruta, M., Noda, T., Sasagawa, K., Sawan, M., & Ohta, J. (2018) · AIP Advances · doi:10.1063/1.5024243 · Cited by 64
High-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Midfield Wireless Power Transfer for Bioelectronics
Ma, A., & Poon, A. S. Y. (2015) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2015.2418999 · Cited by 63
Wireless optogenetics protects against obesity via stimulation of non-canonical fat thermogenesis
Tajima, K., Ikeda, K., Tanabe, Y., Thomson, E. A., Yoneshiro, T., Oguri, Y., Ferro, M. D., Poon, A. S. Y., & Kajimura, S. (2020) · Nature Communications · doi:10.1038/s41467-020-15589-y · Cited by 60
A 2.45-GHz Near-Field RFID System With Passive On-Chip Antenna Tags
Chen, X., Yeoh, W. G., Choi, Y. B., Li, H., & Singh, R. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.921746 · Cited by 60
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Self-Tracking Energy Transfer for Neural Stimulation in Untethered Mice
Ho, J. S., Tanabe, Y., Iyer, S. M., Christensen, A. J., Grosenick, L., Deisseroth, K. A., Delp, S. L., & Poon, A. S. Y. (2015) · Physical Review Applied · doi:10.1103/physrevapplied.4.024001 · Cited by 49
A Method for the Remote Control of Electrical Stimulation of the Nervous System.
El, C., & Ru, L. (1934) · PubMed · Cited by 44
Earlier Intervention with Deep Brain Stimulation for Parkinson’s Disease
Suarez‐Cedeño, G., Suescun, J., & Schiess, M. C. (2017) · Parkinson s Disease · doi:10.1155/2017/9358153 · Cited by 40
Alam, M., Li, S., Ahmed, R. U., Yam, Y. M., Thakur, S., Wang, X.-Y., Tang, D., Ng, S., & Zheng, Y. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0501-4 · Cited by 39
Ultrasound-induced lung hemorrhage: Role of acoustic boundary conditions at the pleural surface
O’Brien, W. D., Kramer, J. M., Waldrop, T. G., Frizzell, L. A., Miller, R. J., Blue, J. P., & Zachary, J. F. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1436068 · Cited by 38
Chen, Z., Su, Y., & Meguid, S. A. (2014) · Journal of Applied Physics · doi:10.1063/1.4901069 · Cited by 38
Distributed sensor and actuator networks for closed-loop bioelectronic medicine
Bhave, G., Chen, J., Singer, A. L., Sharma, A., & Robinson, J. T. (2021) · Materials Today · doi:10.1016/j.mattod.2020.12.020 · Cited by 34
Self-citationEffect of obliquity of incident light on the performance of silicon solar cells
Sharma, R. (2019) · Heliyon · doi:10.1016/j.heliyon.2019.e01965 · Cited by 33
Challenges in Scaling Down of Free-Floating Implantable Neural Interfaces to Millimeter Scale
Yang, K.-W. K., Oh, K., & Ha, S. (2020) · IEEE Access · doi:10.1109/access.2020.3007517 · Cited by 32
Sputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes
Fan, B., Rodriguez, A. V., Vercosa, D. G., Kemere, C. T., & Robinson, J. T. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab965c · Cited by 28
Self-citationWirelessly powered implantable pacemaker with on-chip antenna
Sun, Y., Greet, B. D., Burkland, D. A., John, M. M., Razavi, M., & Babakhani, A. (2017) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2017.8058831 · Cited by 26
Nonlinear converse magnetoelectric effects in a ferromagnetic-piezoelectric bilayer
Fetisov, L. Y., Chashin, D. V., Burdin, D. A., Saveliev, D. V., Ekonomov, N. A., Srinivasan, G., & Fetisov, Y. K. (2018) · Applied Physics Letters · doi:10.1063/1.5054584 · Cited by 26
A 2.4 GHz antenna for medical implanted communications
Yazdandoost, K. Y. (2009) · Asia-Pacific Microwave Conference (APMC) · doi:10.1109/apmc.2009.5384240 · Cited by 22
Oelze, M. L., Miller, R. J., Blue, J. P., Zachary, J. F., & O’Brien, W. D. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2973186 · Cited by 22
Rise of the Visible Monkey: Sectioned Images of Rhesus Monkey
Chung, B. S., Jeon, C., Huh, J., Jeong, K.-J., Har, D., Kwack, K., & Park, J. S. (2019) · Journal of Korean Medical Science · doi:10.3346/jkms.2019.34.e66 · Cited by 19
Geoffroy, O., O'Brien, D., Cugat, O., & Delamare, J. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2034469 · Cited by 14
Effect of vagus nerve stimulation on neural adaptation in thalamo-cortical system in rats
Shiramatsu, T. I., Hitsuyu, R., Ibayashi, K., Kanzaki, R., Kawai, K., & Takahashi, H. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591076 · Cited by 10
Maeng, L. Y., Murillo, M. F., Mu, M., Lo, M.-C., de la Rosa, M., O’Brien, J. M., Freeman, D. K., & Widge, A. S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aafc72 · Cited by 8
Wide dipole antennas for wireless powering of miniaturised bioelectronic devices
Aldaoud, A., Lui, S., Keng, K. S., Moshfegh, S., Soto-Breceda, A., Tong, W., Redouté, J., Garrett, D. J., Wong, Y. T., & Prawer, S. (2019) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2019.100311 · Cited by 5
Turn on the Music: Cochlear Implants.
Bear, Z. W., & Mikulec, A. A. (2016) · Europe PMC (PubMed Central) · Cited by 3
Leadless permanent pacemaker: an article review
Rampengan, S. H., Wijaya, H., Yoga, G., Pangemanan, J. A., & Panda, A. L. (2017) · Medicina Journal · doi:10.15562/medicina.v48i1.16 · Cited by 2
Flagged first, then by citations
1 of the 89 references couldn’t be matched to a known paper.
Research works printed but not linked: 16
- Balcombe J. P., 2004, J. Am. Assoc. Lab. Anim. Sci., 43, 42
- Z.Yu J. C.Chen B. W.Avants Y.He J. T.Robinson K.Yang inIEEE Int. Solid‐State Circuits Conf. IEEE Piscataway NJ2020 pp.6–8.
- Rahmani H., 2017, IEEE MTT‐S Int. Microwave Symp. Digest, 300
- Suarez‐Cedeno G., 2017, Parkinson's Dis., 2017
- Chaffee E. L., 1934, Yale J. Biol. Med., 7, 83
- Bear Z. W., 2016, Mo. Med., 113, 68
- Shiramatsu T. I., 2016, Proc. of the Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society, EMBS, 1834
- Z.Yu J. C.Chen B. W.Avants Y.He A.Singer J. T.Robinson K.Yang inInt. Solid‐State Circuits Conf. IEEE Piscataway NJ2020 pp. 6–8.
- Sun Y., 2017, 2017 IEEE MTT‐S Int. Microwave Symp. (IMS), 1242
- V. W.Leung J.Lee S.Li S.Yu C.Kilfovle L.Larson A.Nurmikko F.Laiwalla inESSCIRC 2018 – IEEE 44th European Solid State Circuits Conf. IEEE Piscataway NJ2018 p. 271.
- W. B.Phillips B. C.Towe P. J.Larson inAnnual Int. Conf. of the IEEE Engineering in Medicine and Biology – Proc. Vol.2 IEEE Piscataway NJ2003 p. 1983.
- Zhai J., 2006, Appl. Phys. Lett., 89, 8
- Fang Z., 2010, MRS. Online Proc. Libr., 1199, 103
- Li M., 2013, Appl. Phys. Lett., 102, 8
- Sharma R., 2019, Heliyon, 5, 01965
- Bhave G., 2021, Mater. Today
Cited by
Sorted by citations
A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves
Chen, J., Kan, P. T. M., Yu, Z., Alrashdan, F. T., Garcia, R., Singer, A. L., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00873-7 · Cited by 237
Self-citationMiniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Self-citationChen, H., Wang, L., Liu, S., Sheng, X., & Yin, L. (2024) · ACS Nano · doi:10.1021/acsnano.3c11832 · Cited by 112
Cea, C., Zhao, Z., Wisniewski, D. J., Spyropoulos, G. D., Polyravas, A. G., Gelinas, J. N., & Khodagholy, D. (2023) · Nature Materials · doi:10.1038/s41563-023-01599-w · Cited by 112
Advancements in Wearable and Implantable BioMEMS Devices: Transforming Healthcare Through Technology
Abhinav, V., Basu, P., Verma, S. S., Verma, J., Das, A., Kumari, S., Yadav, P. R., & Kumar, V. (2025) · Micromachines · doi:10.3390/mi16050522 · Cited by 106
Metadata
- Authors
- Singer, A., & Robinson, J. T.
- Affiliations
- Rice University (US)
- Corresponding author
- Robinson, Jacob T.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2021-06-10
- Volume
- 10
- Issue
- 17
- Pages
- e2100664-e2100664
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- PMC
- PMC8754427
- OpenAlex
- W3172743862
- Cited by
- 159
- References
- 89
- Citations by year
- 2026: 23 · 2025: 38 · 2024: 41 · 2023: 33 · 2022: 19 · 2021: 5
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Advanced Healthcare Materials (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Rice Research Repository (Rice University) (submittedVersion, cc-by)
- Funders
- National Science Foundation (ECCS‐2023849)
- National Institutes of Health (1U18EB029353‐01)
- Defense Advanced Research Projects Agency (FA8650‐21‐2‐7119)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wireless power transfer, implantable bioelectronics, battery-free devices, inductive coupling, radio frequency power transfer, device miniaturization, misalignment tolerance
- MeSH terms
- Electronics, Miniaturization, Electric Power Supplies, Prostheses and Implants, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review