Methylxanthine Drug Monitoring with Wearable Sweat Sensors
Open accessAbstract
Drug monitoring plays crucial roles in doping control and precision medicine. It helps physicians tailor drug dosage for optimal benefits, track patients' compliance to prescriptions, and understand the complex pharmacokinetics of drugs. Conventional drug tests rely on invasive blood draws. While urine and sweat are attractive alternative biofluids, the state‐of‐the‐art methods require separate sample collection and processing steps and fail to provide real‐time information. Here, a wearable platform equipped with an electrochemical differential pulse voltammetry sensing module for drug monitoring is presented. A methylxanthine drug, caffeine, is selected to demonstrate the platform's functionalities. Sweat caffeine levels are monitored under various conditions, such as drug doses and measurement time after drug intake. Elevated sweat caffeine levels upon increasing dosage and confirmable caffeine physiological trends are observed. This work leverages a wearable sweat sensing platform toward noninvasive and continuous point‐of‐care drug monitoring and management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, a wearable sweat-based sensor has been developed for detecting caffeine (a methylxanthine drug) using pilocarpine-based iontophoretic sweat stimulation or exercise-induced sweat92.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [92]
In the citing paper
“Even so, as described, the sensing device was not integrated with the sweat generation device, but rather coupled to a commercially available Macroduct sweat collector using pilocarpine delivery.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [92]
In the citing paper
“Rather than using biological recognition, this sensing platform relied on direct anodic detection of caffeine at a carbon nanotube-based working electrode with a voltammetric scan.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [92]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Self-citationKim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Adverse drug reactions as cause of admission to hospital: prospective analysis of 18 820 patients
Pirmohamed, M., James, S., Meakin, S., Green, C. A., SCOTT, A. K., Walley, T. J., Farrar, K., Park, B. K., & Breckenridge, A. M. (2004) · BMJ · doi:10.1136/bmj.329.7456.15 · Cited by 3,236
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Self-citationSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Self-citationHighly ordered nanowire arrays on plastic substrates for ultrasensitive flexible chemical sensors
McAlpine, M. C., Ahmad, H., Wang, D., & Heath, J. R. (2007) · Nature Materials · doi:10.1038/nmat1891 · Cited by 959
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Self-citationEthnic Disparities in Unmet Need for Alcoholism, Drug Abuse, and Mental Health Care
Wells, K., Klap, R., Koike, A., & Sherbourne, C. (2001) · American Journal of Psychiatry · doi:10.1176/appi.ajp.158.12.2027 · Cited by 773
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Self-citationNoninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Metabolic, Catecholamine, and Exercise Performance Responses to Various Doses of Caffeine
Graham, T. E., & Spriet, L. L. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.78.3.867 · Cited by 488
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W. F., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L., Ota, H., Wu, E. G., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 393
Self-citationNoordzij, M., Uiterwaal, C. S., Arends, L. R., Kok, F. J., Grobbee, D. E., & Geleijnse, J. M. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000166828.94699.1d · Cited by 376
Human Saliva as a Diagnostic Specimen
Hofman, L. F. (2001) · Journal of Nutrition · doi:10.1093/jn/131.5.1621s · Cited by 328
Caffeine Content of Specialty Coffees
McCusker, R. R., Goldberger, B. A., & Cone, E. J. (2003) · Journal of Analytical Toxicology · doi:10.1093/jat/27.7.520 · Cited by 306
Exercise endurance 1, 3, and 6 h after caffeine ingestion in caffeine users and nonusers
Bell, D. G., & McLellan, T. M. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00187.2002 · Cited by 288
Hydrochromic conjugated polymers for human sweat pore mapping
Lee, J., Pyo, M., Lee, S. H., Kim, J., Ra, M., Kim, W.-Y., Park, B. J., Lee, C. W., & Kim, J. (2014) · Nature Communications · doi:10.1038/ncomms4736 · Cited by 277
Highly deformable liquid-state heterojunction sensors
Ota, H., Chen, K., Lin, Y., Kiriya, D., Shiraki, H., Yu, Z., Ha, T., & Javey, A. (2014) · Nature Communications · doi:10.1038/ncomms6032 · Cited by 266
Self-citationEffect of caffeinated drinks on substrate metabolism, caffeine excretion, and performance
Kovacs, E. M. R., Stegen, J. H. C. H., & Brouns, F. J. P. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.709 · Cited by 264
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S. M., Wu, Y., Lau, K. T., Wallace, G. G., & Diamond, D. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 234
Cardiovascular effects of caffeine in men and women
Hartley, T. R., Lovallo, W. R., & Whitsett, T. L. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.12.057 · Cited by 168
Validation of the Direct Analysis in Real Time Source for Use in Forensic Drug Screening
Steiner, R. R., & Larson, R. L. (2009) · Journal of Forensic Sciences · doi:10.1111/j.1556-4029.2009.01006.x · Cited by 165
3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Ota, H., Chao, M., Gao, Y., Wu, E., Tai, L.-C., Chen, K., Matsuoka, Y., Iwai, K., Fahad, H. M., Gao, W., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00247 · Cited by 154
Self-citationInteraction of the anticancer drug epirubicin with DNA
Erdem, A., & Özsöz, M. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00942-4 · Cited by 149
Screening for drugs of abuse in hair with ion spray LC–MS–MS
Kronstrand, R., Nyström, I., Strandberg, J., & Druid, H. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2004.04.034 · Cited by 146
Spriet, L. L. (1995) · International Journal of Sport Nutrition · doi:10.1123/ijsn.5.s1.s84 · Cited by 146
A fully roll-to-roll gravure-printed carbon nanotube-based active matrix for multi-touch sensors
Lee, W., Koo, H., Sun, J., Noh, J., Kwon, K.-S., Yeom, C., Choi, Y., Chen, K., Javey, A., & Cho, G. (2015) · Scientific Reports · doi:10.1038/srep17707 · Cited by 130
Self-citationYarnell, A. M., & Deuster, P. A. (2016) · Journal of Special Operations Medicine · doi:10.55460/wknd-5j8w · Cited by 120
Ruusunen, A. A., Lehto, S. M., Tolmunen, T., Mursu, J., Kaplan, G. A., & Voutilainen, S. (2010) · Public Health Nutrition · doi:10.1017/s1368980010000509 · Cited by 119
Sweat Testing in Opioid Users with a Sweat Patch
Kintz, P., Tracqui, A., Mangin, P., & Edel, Y. (1996) · Journal of Analytical Toxicology · doi:10.1093/jat/20.6.393 · Cited by 119
Monitoring Opiate Use in Substance Abuse Treatment Patients With Sweat and Urine Drug Testing
Huestis, M. A., Cone, E. J., Wong, C. J., Umbricht, A., & Preston, K. L. (2000) · Journal of Analytical Toxicology · doi:10.1093/jat/24.7.509 · Cited by 94
Drug Excretion in Human Eccrine Sweat
Johnson, H. L., & Maïbach, H. I. (1971) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12260784 · Cited by 85
Urine Drug Testing of Chronic Pain Patients: Licit and Illicit Drug Patterns
Cone, E. J., Caplan, Y. H., Black, D. L., Robert, T. A., & Moser, F. (2008) · Journal of Analytical Toxicology · doi:10.1093/jat/32.8.530 · Cited by 84
Dogan‐Topal, B., Uslu, B., & Özkan, S. A. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.12.005 · Cited by 81
Birkett, D., & Miners, J. O. (1991) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1991.tb05553.x · Cited by 77
The Erythromycin Breath Test For the Prediction of Drug Clearance
Rivory, L. P., Slaviero, K. A., Hoskins, J. M., & Clarke, S. J. (2001) · Clinical Pharmacokinetics · doi:10.2165/00003088-200140030-00001 · Cited by 70
Zhao, F., Wang, F., Zhao, W., Zhou, J., Liu, Y., Zou, L., & Ye, B. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0635-y · Cited by 68
Effects of moderate exercise on the pharmacokinetics of caffeine
Collomp, K., Anselme, F., Audran, M., Gay, J. P., Chanal, J. L., & Prefaut, C. (1991) · European Journal of Clinical Pharmacology · doi:10.1007/bf00315209 · Cited by 51
Erdem, A., Karadeniz, H., & Caliskan, A. (2011) · The Analyst · doi:10.1039/c0an00357c · Cited by 46
Chen, W., Liu, L.-L., Li, X., Li, J., Song-gang, J., Zhang, G., & Chai, Y. (2000) · Biomedical Chromatography · doi:10.1002/1099-0801(200012)14:8 · Cited by 19
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Magnus Berggren, A., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,453
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Flexible Electronics toward Wearable Sensing
Gao, W. F., Ota, H., Kiriya, D., Takei, K., & Javey, A. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00500 · Cited by 1,301
Self-citationWearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 854
Metadata
- Authors
- Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., Wu, E., Fahad, H. M., Lien, D., Ota, H., Cho, G., & Javey, A.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Sunchon National University (KR)
- Corresponding author
- Javey, Ali
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-04-16
- Volume
- 30
- Issue
- 23
- Pages
- e1707442-e1707442
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2800594651
- Cited by
- 310
- References
- 50
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 39 · 2023: 40 · 2022: 38 · 2021: 47 · 2020: 51 · 2019: 39 · 2018: 5
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
- Funders
- U.S. Department of Energy (DE‐AC02‐05CH11231)
- Japan Society for the Promotion of Science
- Ministry of Food and Drug Safety (16163KKMFDS001)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- methylxanthines, caffeine, sweat sensors, wearable sensors, non-invasive drug monitoring, point-of-care testing, doping control, pharmacokinetics
- MeSH terms
- Wearable Electronic Devices, Humans, Monitoring, Physiologic, Sweat, Xanthines, Drug Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review