Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A Tumor‐Microenvironment‐Responsive Lanthanide–Cyanine FRET Sensor for NIR‐II Luminescence‐Lifetime In Situ Imaging of Hepatocellular Carcinoma

Zhao, Mengyao, Li, Benhao, Wu, Yifan, He, Haisheng, Zhu, Xinyan, Zhang, Hongxin, Dou, Chaoran, Feng, Lishuai, Fan, Yong, Zhang, Fan·2020·Advanced Materials

Abstract

Deep tissue imaging in the second near‐infrared (NIR‐II) window holds great promise for widespread fundamental research. However, inhomogeneous signal attenuation due to tissue absorption and scattering hampers its application for accurate in vivo biosensing. Here, lifetime‐based in situ hepatocellular carcinoma (HCC) detection in NIR‐II region is presented using a tumor‐microenvironment (peroxynitrite, ONOO−)‐responsive lanthanide–cyanine Förster resonance energy transfer (FRET) nanosensor. A specially designed ONOO−‐responsive NIR‐II dye, MY‐1057, is synthesized as the FRET acceptor. Robust lifetime sensing is demonstrated to be independent of tissue penetration depth. Tumor lesions are accurately distinguished from normal tissue due to the recovery lifetime. Magnetic resonance imaging and liver dissection results illustrate the reliability of lifetime‐based detection in single and multiple HCC models. Moreover, the ONOO− amount can be calculated according to the standard curve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202001172

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 236

Metadata

Authors
Zhao, M., Li, B., Wu, Y., He, H., Zhu, X., Zhang, H., Dou, C., Feng, L., Fan, Y., & Zhang, F.
Venue
Advanced Materials
Publisher
Wiley
Published
2020-06-03
Volume
32
Issue
28
Pages
e2001172-e2001172
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3030954911
Cited by
236
References
8
FWCI
14.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Tumor‐Microenvironment‐Responsive Lanthanide–Cyanine FRET Sensor for NIR‐II Luminescence‐Lifetime In Situ Imaging of Hepatocellular Carcinoma. https://app.cochat.ai/papers/10.1002/adma.202001172
The paper
Zhao, M., Li, B., Wu, Y., He, H., Zhu, X., Zhang, H., Dou, C., Feng, L., Fan, Y., & Zhang, F. (2020). A Tumor‐Microenvironment‐Responsive Lanthanide–Cyanine FRET Sensor for NIR‐II Luminescence‐Lifetime In Situ Imaging of Hepatocellular Carcinoma. Advanced Materials. https://doi.org/10.1002/adma.202001172

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.