Quantifying axonal loss after optic neuritis with optical coherence tomography
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Objective: To determine to what degree changes in retinal nerve fiber layer (RNFL) thickness after optic neuritis (ON) correlate with either visual recovery or impairment. Methods: ON can cause visible defects within the RNFL, which can be quantified using optical coherence tomography (OCT). It may be possible to predict visual recovery by measuring RNFL loss after ON. Fifty‐four patients underwent repeated evaluations with optical coherence tomography and standardized ophthalmic testing after ON. Regression analyses were used to determine the relationship between RNFL thickness and visual function. Results: Thinning of the RNFL was seen in the majority of patients (74%), and it tended to occur within 3 to 6 months of ON. The average RNFL value was thinner (p < 0.0001) in the affected (78μm) compared with the unaffected eye (100μm). Patients with incomplete visual recovery demonstrated greater RNFL loss after ON. Regression analyses demonstrated a threshold of RNFL thickness (75μm), below which RNFL measurements predicted persistent visual dysfunction. Interpretation: Determination of RNFL thickness may predict visual recovery after ON, and lower RNFL values correlate with impaired visual function. Optical coherence tomography may have a potential role as a surrogate marker for axonal integrity within the optic nerve among patients with ON. Ann Neurol 2006;59:963–969
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
New diagnostic criteria for multiple sclerosis: Guidelines for research protocols
Poser, C. M., Paty, D. W., Scheinberg, L., McDonald, W. I., Davis, F. A., Ebers, G. C., Johnson, K. P., Sibley, W. A., Silberberg, D. H., & Tourtellotte, W. W. (1983) · Annals of Neurology · doi:10.1002/ana.410130302 · Cited by 7,384
Axonal transection in the lesions of multiple sclerosis
Trapp, B. D., Peterson, J., Ransohoff, R. M., Rudick, R., Mörk, S., & Bö, L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801293380502 · Cited by 4,029
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
A Randomized, Controlled Trial of Corticosteroids in the Treatment of Acute Optic Neuritis
Beck, R. W., Cleary, P. A., Anderson, M. M., Keltner, J. L., Shults, W. T., Kaufman, D. I., Buckley, E. G., Corbett, J. J., Kupersmith, M. J., Miller, N. R., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199202273260901 · Cited by 1,355
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Schuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Relation of Visual Function to Retinal Nerve Fiber Layer Thickness in Multiple Sclerosis
FISHER, J., JACOBS, D., MARKOWITZ, C., GALETTA, S., VOLPE, N., NANOSCHIAVI, M., BAIER, M., FROHMAN, E., WINSLOW, H., & FROHMAN, T. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.040 · Cited by 658
The Clinical Profile of Optic Neuritis: Experience of the Optic Neuritis Treatment Trial
(1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080120057025 · Cited by 600
Miller, D., Barkhof, F., Montalban, X., Thompson, A., & Filippi, M. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70071-5 · Cited by 594
Cited by
Toosy, A. T., Mason, D. F., & Miller, D. H. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70259-x · Cited by 617
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Self-citationGreen, A. J., McQuaid, S., Hauser, S. L., Allen, I. V., & Lyness, R. (2010) · Brain · doi:10.1093/brain/awq080 · Cited by 487
Retinal nerve fiber layer is associated with brain atrophy in multiple sclerosis
Gordon-Lipkin, E., Chodkowski, B., Reich, D. S., Smith, S. A., Pulicken, M., Balcer, L. J., Frohman, E. M., Cutter, G., & Calabresi, P. A. (2007) · Neurology · doi:10.1212/01.wnl.0000295995.46586.ae · Cited by 419
Multiple sclerosis in children: clinical diagnosis, therapeutic strategies, and future directions
Banwell, B., Ghezzi, A., Bar-Or, A., Mikaeloff, Y., & Tardieu, M. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70242-9 · Cited by 394
Optical coherence tomography reflects brain atrophy in multiple sclerosis: A four‐year study
Saidha, S., Al‐Louzi, O., Ratchford, J. N., Bhargava, P., Oh, J., Newsome, S. D., Prince, J. L., Pham, D., Roy, S., van Zijl, P., et al. (2015) · Annals of Neurology · doi:10.1002/ana.24487 · Cited by 391
Imaging outcomes for neuroprotection and repair in multiple sclerosis trials
Barkhof, F., Calabresi, P. A., Miller, D. H., & Reingold, S. C. (2009) · Nature Reviews Neurology · doi:10.1038/nrneurol.2009.41 · Cited by 378
Longitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis
Talman, L. S., Bisker, E. R., Sackel, D. J., Long, D. A., Galetta, K. M., Ratchford, J. N., Lile, D. J., Farrell, S. K., Loguidice, M. J., Remington, G., et al. (2010) · Annals of Neurology · doi:10.1002/ana.22005 · Cited by 366
Optical coherence tomography segmentation reveals ganglion cell layer pathology after optic neuritis
Syc, S. B., Saidha, S., Newsome, S. D., Ratchford, J. N., Levy, M., Ford, E., Crainiceanu, C. M., Durbin, M. K., Oakley, J. D., Meyer, S. A., et al. (2012) · Brain · doi:10.1093/brain/awr264 · Cited by 348
Martinez-Lapiscina, E. H., Arnow, S., Wilson, J. A., Saidha, S., Preiningerova, J. L., Oberwahrenbrock, T., Brandt, A. U., Pablo, L. E., Guerrieri, S., Gonzalez, I., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)00068-5 · Cited by 332
Self-citationMicrocystic macular oedema in multiple sclerosis is associated with disease severity
Gelfand, J. M., Nolan, R., Schwartz, D. M., Graves, J., & Green, A. J. (2012) · Brain · doi:10.1093/brain/aws098 · Cited by 331
Optical coherence tomography: a window into the mechanisms of multiple sclerosis
Frohman, E. M., Fujimoto, J. G., Frohman, T. C., Calabresi, P. A., Cutter, G., & Balcer, L. J. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0950 · Cited by 326
Sechi, E., Cacciaguerra, L., Chen, J. J., Mariotto, S., Fadda, G., Dinoto, A., Lopez-Chiriboga, A. S., Pittock, S. J., & Flanagan, E. P. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.885218 · Cited by 325
Diagnostic accuracy of retinal abnormalities in predicting disease activity in MS
Sepulcre, J., Murie-Fernandez, M., Salinas-Alaman, A., García-Layana, A., Bejarano, B., & Villoslada, P. (2007) · Neurology · doi:10.1212/01.wnl.0000260612.51849.ed · Cited by 298
Optical coherence tomography and disease subtype in multiple sclerosis
Pulicken, M., Gordon-Lipkin, E., Balcer, L. J., Frohman, E., Cutter, G., & Calabresi, P. A. (2007) · Neurology · doi:10.1212/01.wnl.0000294876.49861.dc · Cited by 298
Saidha, S., Syc, S. B., Durbin, M. K., Eckstein, C., Oakley, J. D., Meyer, S. A., Conger, A., Frohman, T. C., Newsome, S., Ratchford, J. N., et al. (2011) · Multiple Sclerosis Journal · doi:10.1177/1352458511418630 · Cited by 296
The investigation of acute optic neuritis: a review and proposed protocol
Petzold, A., Wattjes, M. P., Costello, F., Flores-Rivera, J., Fraser, C. L., Fujihara, K., Leavitt, J., Marignier, R., Paul, F., Schippling, S., et al. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.108 · Cited by 270
Self-citationHenderson, A. P. D., Trip, S. A., Schlottmann, P. G., Altmann, D. R., Garway-Heath, D. F., Plant, G. T., & Miller, D. H. (2007) · Brain · doi:10.1093/brain/awm285 · Cited by 239
Optic neuritis and autoimmune optic neuropathies: advances in diagnosis and treatment
Bennett, J. L., Costello, F., Chen, J. J., Petzold, A., Biousse, V., Newman, N. J., & Galetta, S. L. (2023) · The Lancet Neurology · doi:10.1016/s1474-4422(22)00187-9 · Cited by 226
Self-citationBurkholder, B. M., Osborne, B., Loguidice, M. J., Bisker, E., Frohman, T. C., Conger, A., Ratchford, J. N., Warner, C., Markowitz, C. E., Jacobs, D. A., et al. (2009) · Archives of Neurology · doi:10.1001/archneurol.2009.230 · Cited by 199
Optical Coherence Tomography (OCT): Imaging the Visual Pathway as a Model for Neurodegeneration
Galetta, K. M., Calabresi, P. A., Frohman, E. M., & Balcer, L. J. (2011) · Neurotherapeutics · doi:10.1007/s13311-010-0005-1 · Cited by 185
Dynamics of retinal injury after acute optic neuritis
Gabilondo, I., Martínez‐Lapiscina, E. H., Fraga‐Pumar, E., Ortiz‐Perez, S., Torres‐Torres, R., Andorra, M., Llufriu, S., Zubizarreta, I., Saiz, A., Sanchez‐Dalmau, B., et al. (2015) · Annals of Neurology · doi:10.1002/ana.24351 · Cited by 178
Axonal loss and myelin in early ON loss in postacute optic neuritis
Klistorner, A., Arvind, H., Nguyen, T., Garrick, R., Paine, M., Graham, S., O'Day, J., Grigg, J., Billson, F., & Yiannikas, C. (2008) · Annals of Neurology · doi:10.1002/ana.21474 · Cited by 177
Balcer, L. J., Raynowska, J., Nolan, R., Galetta, S. L., Kapoor, R., Benedict, R., Phillips, G., LaRocca, N., Hudson, L., Rudick, R., et al. (2017) · Multiple Sclerosis Journal · doi:10.1177/1352458517690822 · Cited by 168
Resveratrol Neuroprotection in a Chronic Mouse Model of Multiple Sclerosis
Fonseca-Kelly, Z., Nassrallah, M., Uribe, J., Khan, R. S., Dine, K., Dutt, M., & Shindler, K. S. (2012) · Frontiers in Neurology · doi:10.3389/fneur.2012.00084 · Cited by 166
The role of autophagy in axonal degeneration of the optic nerve
Koch, J. C., & Lingor, P. (2016) · Experimental Eye Research · doi:10.1016/j.exer.2015.08.016 · Cited by 46
Diffusion MRI quantifies early axonal loss in the presence of nerve swelling
Lin, T.-H., Chiang, C.-W., Perez-Torres, C. J., Sun, P., Wallendorf, M., Schmidt, R. E., Cross, A. H., & Song, S.-K. (2017) · Journal of Neuroinflammation · doi:10.1186/s12974-017-0852-3 · Cited by 42
Wicki, C. A., Hanson, J. V. M., & Schippling, S. (2018) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000604 · Cited by 16
Mauceri, V. A., Puthenparampil, M., Gallo, P., & Petzold, A. (2025) · BMJ Neurology Open · doi:10.1136/bmjno-2025-001118 · Cited by 7
“The incorporation of widely available OCT metrics, such as mGCL (ordepending on the OCT vendor, mGCIPL) volume,”
Metadata
- Authors
- Costello, F., Coupland, S., Hodge, W., Lorello, G. R., Koroluk, J., Pan, Y. I., Freedman, M. S., Zackon, D. H., & Kardon, R. H.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 2006-05-22
- Volume
- 59
- Issue
- 6
- Pages
- 963-969
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W2115404493
- Cited by
- 610
- References
- 27
- FWCI
- 20.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.