The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Injectable Microbubbles as Contrast Agents for Diagnostic Ultrasound Imaging: The Key Role of Perfluorochemicals
Abstract
Ultrasonography has, until recently, lacked effective contrast‐enhancing agents. Micrometer‐sized gas bubbles that resonate at a diagnostic frequency are ideal reflectors for ultrasound. However, simple air bubbles, when injected into the blood stream, disappear within seconds through the combined effects of Laplace pressure, blood pressure, and exposure to ultrasound energy. Use of fluorocarbon vapor, by extending the persistence of microbubbles in vivo from seconds to minutes, propelled contrast ultrasonography into clinical practice. Imaging techniques that selectively suppress tissue, but not microbubble signal, further increase image contrast. Approved products consist of C 3 F 8 or SF 6 microbubbles, and N 2 microbubbles osmotically stabilized with C 6 F 14. These agents allow the detection and characterization of cardiovascular abnormalities and solid organ lesions, such as tumors. By providing higher quality images, they improve the accuracy and confidence of disease diagnosis, and can play a decisive role in clinical decision making. New objectives include agents that target specific cells for the molecular imaging of disease, and drug and gene delivery, including ultrasound‐triggered delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morse, P. M., Ingard, K. U., & Beyer, R. T. (1969) · Journal of Applied Mechanics · doi:10.1115/1.3564682 · Cited by 3,188
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Echocardiography of the Aortic Root
Gramiak, R., & Shah, P. M. (1968) · Investigative Radiology · doi:10.1097/00004424-196809000-00011 · Cited by 930
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Self-citationAdvances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Acoustic droplet vaporization for therapeutic and diagnostic applications
Kripfgans, O. D., Fowlkes, J. B., Miller, D. L., Eldevik, O. P., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00262-3 · Cited by 572
Fluorocarbons and fluorinated amphiphiles in drug delivery and biomedical research
Krafft, M. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00107-7 · Cited by 550
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Lindner, J. R., Song, J., Christiansen, J., Klibanov, A. L., Xu, F., & Ley, K. (2001) · Circulation · doi:10.1161/hc4201.097061 · Cited by 441
Cited by
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Anselmo, A. C., & Mitragotri, S. (2016) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10003 · Cited by 1,321
Qian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
Membrane Electroporation and Electropermeabilization: Mechanisms and Models
Kotnik, T., Rems, L., Tarek, M., & Miklavčič, D. (2019) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-052118-115451 · Cited by 813
Conquering the Hypoxia Limitation for Photodynamic Therapy
Wan, Y., Fu, L., Li, C., Lin, J., & Huang, P. (2021) · Advanced Materials · doi:10.1002/adma.202103978 · Cited by 705
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Gao, M., Liang, C., Song, X., Chen, Q., Jin, Q., Wang, C., & Liu, Z. (2017) · Advanced Materials · doi:10.1002/adma.201701429 · Cited by 590
Krafft, M. P., & Riess, J. G. (2009) · Chemical Reviews · doi:10.1021/cr800260k · Cited by 497
Self-citationThe fluorous effect in biomolecular applications
Cametti, M., Crousse, B., Metrangolo, P., Milani, R., & Resnati, G. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15084g · Cited by 476
Li, W.-P., Su, C.-H., Chang, Y.-C., Lin, Y.-J., & Yeh, C.-S. (2016) · ACS Nano · doi:10.1021/acsnano.5b06175 · Cited by 437
Riess, J. G. (2005) · Artificial Cells, Blood Substitutes, and Biotechnology · doi:10.1081/bio-200046659 · Cited by 361
Self-citationGas‐Generating Nanoplatforms: Material Chemistry, Multifunctionality, and Gas Therapy
Yu, L., Hu, P., & Chen, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801964 · Cited by 360
Chen, Y., & Shi, J. (2016) · Advanced Materials · doi:10.1002/adma.201505147 · Cited by 356
Kagan, D., Benchimol, M. J., Claussen, J. C., Chuluun‐Erdene, E., Esener, S., & Wang, J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201902 · Cited by 336
Krafft, M. P., & Riess, J. G. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2014.08.039 · Cited by 303
Self-citationEvolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery
Paefgen, V., Doleschel, D., & Kiessling, F. (2015) · Frontiers in Pharmacology · doi:10.3389/fphar.2015.00197 · Cited by 272
Recent advances in stimuli-responsive polymer systems for remotely controlled drug release
Zhang, A., Jung, K., Li, A., Liu, J., & Boyer, C. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101164 · Cited by 268
Min, K. H., Min, H. S., Lee, H. J., Park, D. J., Yhee, J. Y., Kim, K., Kwon, I. C., Jeong, S. Y., Silvestre, O. F., Chen, X., et al. (2015) · ACS Nano · doi:10.1021/nn506210a · Cited by 265
Theranostic USPIO‐Loaded Microbubbles for Mediating and Monitoring Blood‐Brain Barrier Permeation
Lammers, T., Koczera, P., Fokong, S., Gremse, F., Ehling, J., Vogt, M., Pich, A., Storm, G., van Zandvoort, M., & Kiessling, F. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201401199 · Cited by 156
Ma, X., Yao, M., Shi, J., Li, X., Gao, Y., Luo, Q., Hou, R., Liang, X., & Wang, F. (2020) · ACS Nano · doi:10.1021/acsnano.0c07287 · Cited by 110
Metadata
- Authors
- Schutt, E. G., Klein, D. H., Mattrey, R. M., & Riess, J. G.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2003-07-16
- Volume
- 42
- Issue
- 28
- Pages
- 3218-3235
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2153057832
- Cited by
- 543
- References
- 40
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.