CoChat

Engineering of Reversible NIR‐II Redox‐Responsive Fluorescent Probes for Imaging of Inflammation In Vivo

He, Long, He, Lin‐Hui, Xu, Shuai, Ren, Tian‐Bing, Zhang, Xing‐Xing, Qin, Zuo‐Jia, Zhang, Xiao‐Bing, Yuan, Lin · 2022 · Angewandte Chemie International Edition
Cited by 137

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

The second near‐infrared (NIR‐II) fluorescent imaging shows great potential for deep tissue analysis at high resolution in living body owing to low background autofluorescence and photon scattering. However, reversible monitoring of redox homeostasis using NIR‐II fluorescent imaging remains a challenge due to the lack of appropriate probes. In this study, a series of stable and multifunctional NIR‐II dyes (NIR‐II Cy3s) were constructed based on trimethine skeleton. Significantly, introducing the 1,4‐diethyl‐decahydroquinoxaline group to the NIR‐II Cy3s not only effectively increased the wavelength, but also served as an effective response site for HClO, which can be restored by reactive sulfur species (RSS). Based on this,NIR‐II Cy3s were used for reversible monitoring of HClO/RSS‐mediated redox processes in the pathophysiology environment. Finally,NIR‐II Cy3‐988 was successfully utilized for assessment of the redox environments and drug treatment effects in acute inflammation model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.202211409

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 137

Metadata

Authors
He, L., He, L., Xu, S., Ren, T., Zhang, X., Qin, Z., Zhang, X., & Yuan, L.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2022-10-17
Volume
61
Issue
46
Pages
e202211409-e202211409
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W4296809688
Cited by
137
References
24
FWCI
9.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Engineering of Reversible NIR‐II Redox‐Responsive Fluorescent Probes for Imaging of Inflammation In Vivo. https://app.cochat.ai/papers/10.1002/anie.202211409
The paper
He, L., He, L., Xu, S., Ren, T., Zhang, X., Qin, Z., Zhang, X., & Yuan, L. (2022). Engineering of Reversible NIR‐II Redox‐Responsive Fluorescent Probes for Imaging of Inflammation In Vivo. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202211409

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.