The DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.
Phototoxicity in live fluorescence microscopy, and how to avoid it
Abstract
Phototoxicity frequently occurs during live fluorescence microscopy, and its consequences are often underestimated. Damage to cellular macromolecules upon excitation light illumination can impair sample physiology, and even lead to sample death. In this review, we explain how phototoxicity influences live samples, and we highlight that, besides the obvious effects of phototoxicity, there are often subtler consequences of illumination that are imperceptible when only the morphology of samples is examined. Such less apparent manifestations of phototoxicity are equally problematic, and can change the conclusions drawn from an experiment. Thus, limiting phototoxicity is a prerequisite for obtaining reproducible quantitative data on biological processes. We present strategies to reduce phototoxicity, e.g. limiting the illumination to the focal plane and suggest controls for phototoxicity effects. Overall, we argue that phototoxicity needs increased attention from researchers when designing experiments, and when evaluating research findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
TrackMate: An open and extensible platform for single-particle tracking
Tinevez, J.-Y., Perry, N., Schindelin, J., Hoopes, G. M., Reynolds, G. D., Laplantine, E., Bednarek, S. Y., Shorte, S. L., & Eliceiri, K. W. (2017) · Methods · doi:10.1016/j.ymeth.2016.09.016 · Cited by 3,380
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Lattice light-sheet microscopy: Imaging molecules to embryos at high spatiotemporal resolution
Chen, B.-C., Legant, W. R., Wang, K., Shao, L., Milkie, D. E., Davidson, M. W., Janetopoulos, C., Wu, X. S., Hammer, J. A., Liu, Z., et al. (2014) · Science · doi:10.1126/science.1257998 · Cited by 1,919
Reconstruction of Zebrafish Early Embryonic Development by Scanned Light Sheet Microscopy
Keller, P. J., Schmidt, A. D., Wittbrodt, J., & Stelzer, E. H. K. (2008) · Science · doi:10.1126/science.1162493 · Cited by 1,560
Highly inclined thin illumination enables clear single-molecule imaging in cells
Tokunaga, M., Imamoto, N., & Sakata-Sogawa, K. (2008) · Nature Methods · doi:10.1038/nmeth1171 · Cited by 1,305
Rapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination
Planchon, T. A., Gao, L., Milkie, D. E., Davidson, M. W., Galbraith, J. A., Galbraith, C. G., & Betzig, E. (2011) · Nature Methods · doi:10.1038/nmeth.1586 · Cited by 1,112
Improving the photostability of bright monomeric orange and red fluorescent proteins
Shaner, N. C., Lin, M. Z., McKeown, M. R., Steinbach, P. A., Hazelwood, K. L., Davidson, M. W., & Tsien, R. Y. (2008) · Nature Methods · doi:10.1038/nmeth.1209 · Cited by 1,009
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959
Shu, X., Lev-Ram, V., Deerinck, T. J., Qi, Y., Ramko, E. B., Davidson, M. W., Jin, Y., Ellisman, M. H., & Tsien, R. Y. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1001041 · Cited by 827
Microscopy with self-reconstructing beams
Fahrbach, F. O., Simon, P., & Rohrbach, A. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.204 · Cited by 697
Bright monomeric red fluorescent protein with an extended fluorescence lifetime
Merzlyak, E. M., Goedhart, J., Shcherbo, D., Bulina, M. E., Shcheglov, A. S., Fradkov, A. F., Gaintzeva, A., Lukyanov, K. A., Lukyanov, S., Gadella, T. W. J., et al. (2007) · Nature Methods · doi:10.1038/nmeth1062 · Cited by 643
A guide to light-sheet fluorescence microscopy for multiscale imaging
Power, R. M., & Huisken, J. (2017) · Nature Methods · doi:10.1038/nmeth.4224 · Cited by 636
Accuracy and precision in quantitative fluorescence microscopy
Waters, J. C. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200903097 · Cited by 613
Self-citationA genetically encoded photosensitizer
Bulina, M. E., Chudakov, D. M., Britanova, O. V., Yanushevich, Y. G., Staroverov, D. B., Chepurnykh, T. V., Merzlyak, E. M., Shkrob, M. A., Lukyanov, S., & Lukyanov, K. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1175 · Cited by 589
Bouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566
Long-Range Directional Movement of an Interphase Chromosome Site
Chuang, C.-H., Carpenter, A. E., Fuchsova, B., Johnson, T., de Lanerolle, P., & Belmont, A. S. (2006) · Current Biology · doi:10.1016/j.cub.2006.03.059 · Cited by 556
Light-induced cell damage in live-cell super-resolution microscopy
Wäldchen, S., Lehmann, J., Klein, T., van de Linde, S., & Sauer, M. (2015) · Scientific Reports · doi:10.1038/srep15348 · Cited by 536
Photobleaching in Two-Photon Excitation Microscopy
Patterson, G. H., & Piston, D. W. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76762-2 · Cited by 527
Quantitative assessment of fluorescent proteins
Cranfill, P. J., Sell, B. R., Baird, M. A., Allen, J. R., Lavagnino, Z., de Gruiter, H. M., Kremers, G.-J., Davidson, M. W., Ustione, A., & Piston, D. W. (2016) · Nature Methods · doi:10.1038/nmeth.3891 · Cited by 497
How we are shaped: The biomechanics of gastrulation
Keller, R., Davidson, L. A., & Shook, D. R. (2003) · Differentiation · doi:10.1046/j.1432-0436.2003.710301.x · Cited by 494
Deep and fast live imaging with two-photon scanned light-sheet microscopy
Truong, T. V., Supatto, W., Koos, D. S., Choi, J. M., & Fraser, S. E. (2011) · Nature Methods · doi:10.1038/nmeth.1652 · Cited by 489
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Hoebe, R. A., Van Oven, C. H., Gadella, T. W. J., Dhonukshe, P. B., Van Noorden, C. J. F., & Manders, E. M. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1278 · Cited by 435
Estimating Intracellular Calcium Concentrations and Buffering without Wavelength Ratioing
Maravall, M., Mainen, Z. F., Sabatini, B. L., & Svoboda, K. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76809-3 · Cited by 416
High-resolution three-dimensional imaging of large specimens with light sheet–based microscopy
Verveer, P. J., Swoger, J., Pampaloni, F., Greger, K., Marcello, M., & Stelzer, E. H. K. (2007) · Nature Methods · doi:10.1038/nmeth1017 · Cited by 361
Anatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Khodjakov, A., & Rieder, C. L. (2001) · The Journal of Cell Biology · doi:10.1083/jcb.153.1.237 · Cited by 345
Fluorescence live cell imaging
Ettinger, A., & Wittmann, T. (2014) · Methods in Cell Biology · doi:10.1016/b978-0-12-420138-5.00005-7 · Cited by 334
Light-sheet fluorescence microscopy for quantitative biology
Stelzer, E. H. K. (2015) · Nature Methods · doi:10.1038/nmeth.3219 · Cited by 325
Dixit, R., & Cyr, R. (2003) · The Plant Journal · doi:10.1046/j.1365-313x.2003.01868.x · Cited by 316
Wu, Y., Ghitani, A., Christensen, R., Santella, A., Du, Z., Rondeau, G., Bao, Z., Colón-Ramos, D., & Shroff, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108494108 · Cited by 304
Live-cell microscopy – tips and tools
Frigault, M. M., Lacoste, J., Swift, J. L., & Brown, C. M. (2009) · Journal of Cell Science · doi:10.1242/jcs.033837 · Cited by 304
Major signal increase in fluorescence microscopy through dark-state relaxation
Donnert, G., Eggeling, C., & Hell, S. W. (2007) · Nature Methods · doi:10.1038/nmeth986 · Cited by 291
Synaptic amplification by dendritic spines enhances input cooperativity
Harnett, M. T., Makara, J. K., Spruston, N., Kath, W. L., & Magee, J. C. (2012) · Nature · doi:10.1038/nature11554 · Cited by 288
In Vivo Molecular Bioluminescence Imaging: New Tools and Applications
Mezzanotte, L., van ‘t Root, M., Karatas, H., Goun, E. A., & Löwik, C. W. G. M. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.012 · Cited by 288
Ca2+ Fluorescence Imaging with Pico- and Femtosecond Two-Photon Excitation: Signal and Photodamage
Koester, H. J., Baur, D., Uhl, R., & Hell, S. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77063-3 · Cited by 264
König, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J. (1999) · Optics Letters · doi:10.1364/ol.24.000113 · Cited by 259
Five colour variants of bright luminescent protein for real-time multicolour bioimaging
Suzuki, K., Kimura, T., Shinoda, H., Bai, G., Daniels, M. J., Arai, Y., Nakano, M., & Nagai, T. (2016) · Nature Communications · doi:10.1038/ncomms13718 · Cited by 255
High-speed, low-photodamage nonlinear imaging using passive pulse splitters
Ji, N., Magee, J. C., & Betzig, E. (2008) · Nature Methods · doi:10.1038/nmeth.1175 · Cited by 248
Challenges in long-term imaging and quantification of single-cell dynamics
Skylaki, S., Hilsenbeck, O., & Schroeder, T. (2016) · Nature Biotechnology · doi:10.1038/nbt.3713 · Cited by 239
Whole-animal functional and developmental imaging with isotropic spatial resolution
Chhetri, R. K., Amat, F., Wan, Y., Höckendorf, B., Lemon, W. C., & Keller, P. J. (2015) · Nature Methods · doi:10.1038/nmeth.3632 · Cited by 235
Circumventing Photodamage in Live-Cell Microscopy
Magidson, V., & Khodjakov, A. (2013) · Methods in Cell Biology · doi:10.1016/b978-0-12-407761-4.00023-3 · Cited by 231
High-resolution reconstruction of the beating zebrafish heart
Mickoleit, M., Schmid, B., Weber, M., Fahrbach, F. O., Hombach, S., Reischauer, S., & Huisken, J. (2014) · Nature Methods · doi:10.1038/nmeth.3037 · Cited by 229
Self-citationLight sheet‐based fluorescence microscopy: More dimensions, more photons, and less photodamage
Reynaud, E. G., Kržič, U., Greger, K., & Stelzer, E. H. K. (2008) · HFSP Journal · doi:10.2976/1.2974980 · Cited by 213
Improved Blue, Green, and Red Fluorescent Protein Tagging Vectors for S. cerevisiae
Lee, S., Lim, W. A., & Thorn, K. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067902 · Cited by 210
A noncytotoxic DsRed variant for whole-cell labeling
Strack, R. L., Strongin, D. E., Bhattacharyya, D., Tao, W., Berman, A., Broxmeyer, H. E., Keenan, R. J., & Glick, B. S. (2008) · Nature Methods · doi:10.1038/nmeth.1264 · Cited by 193
Fast live simultaneous multiwavelength four-dimensional optical microscopy
Carlton, P. M., Boulanger, J., Kervrann, C., Sibarita, J.-B., Salamero, J., Gordon-Messer, S., Bressan, D., Haber, J. E., Haase, S., Shao, L., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004037107 · Cited by 186
Inverted light-sheet microscope for imaging mouse pre-implantation development
Strnad, P., Gunther, S., Reichmann, J., Krzic, U., Balazs, B., de Medeiros, G., Norlin, N., Hiiragi, T., Hufnagel, L., & Ellenberg, J. (2016) · Nature Methods · doi:10.1038/nmeth.3690 · Cited by 182
Maizel, A., von Wangenheim, D., Federici, F., Haseloff, J., & Stelzer, E. H. K. (2011) · The Plant Journal · doi:10.1111/j.1365-313x.2011.04692.x · Cited by 166
Uetake, Y., Lončarek, J., Nordberg, J. J., English, C. N., Terra, S. L., Khodjakov, A. L., & Sluder, G. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200607073 · Cited by 165
Structural Basis for Phototoxicity of the Genetically Encoded Photosensitizer KillerRed
Pletnev, S. V., Gurskaya, N. G., Pletneva, N. V., Lukyanov, K. A., Chudakov, D. M., Martynov, V. I., Popov, V. O., Kovalchuk, M. V., Wlodawer, A., Dauter, Z., et al. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.054973 · Cited by 147
Comparative assessment of fluorescent proteins for in vivo imaging in an animal model system
Heppert, J. K., Dickinson, D. J., Pani, A. M., Higgins, C. D., Steward, A., Ahringer, J., Kuhn, J. R., & Goldstein, B. (2016) · Molecular Biology of the Cell · doi:10.1091/mbc.e16-01-0063 · Cited by 143
Leung, L. C., Klopper, A. V., Grill, S. W., Harris, W. A., & Norden, C. (2011) · Development · doi:10.1242/dev.071522 · Cited by 128
Self-citationEvaluating performance in three‐dimensional fluorescence microscopy
MURRAY, J. M., Appleton, P. L., Swedlow, J. R., & Waters, J. C. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01861.x · Cited by 128
Self-citationLive-cell imaging: The cell's perspective
Cole, R. W. (2014) · Cell Adhesion & Migration · doi:10.4161/cam.28348 · Cited by 126
Live cell imaging using confocal microscopy induces intracellular calcium transients and cell death
Knight, M. M., Roberts, S. R., Lee, D. A., & Bader, D. L. (2003) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00276.2002 · Cited by 124
Hyperspectral light sheet microscopy
Jahr, W., Schmid, B., Schmied, C., Fahrbach, F. O., & Huisken, J. (2015) · Nature Communications · doi:10.1038/ncomms8990 · Cited by 123
Decrease in Cell Volume Generates Contractile Forces Driving Dorsal Closure
Saïas, L., Swoger, J., D’Angelo, A., Hayes, P., Colombelli, J., Sharpe, J. A., Salbreux, G., & Solon, J. (2015) · Developmental Cell · doi:10.1016/j.devcel.2015.03.016 · Cited by 118
Structural basis for the phototoxicity of the fluorescent protein KillerRed
Carpentier, P., Violot, S., Blanchoin, L., & Bourgeois, D. (2009) · FEBS Letters · doi:10.1016/j.febslet.2009.07.041 · Cited by 110
A coral-on-a-chip microfluidic platform enabling live-imaging microscopy of reef-building corals
Shapiro, O. H., Kramarsky‐Winter, E., Gavish, A. R., Stocker, R., & Vardi, A. (2016) · Nature Communications · doi:10.1038/ncomms10860 · Cited by 110
Surpassing light-induced cell damage in vitro with novel cell culture media
Stockley, J. H., Evans, K. A., Matthey, M., Volbracht, K., Agathou, S., Mukanowa, J., Burrone, J., & Káradóttir, R. T. (2017) · Scientific Reports · doi:10.1038/s41598-017-00829-x · Cited by 107
Weber, M., Mickoleit, M., & Huisken, J. (2014) · Methods in cell biology · doi:10.1016/b978-0-12-420138-5.00011-2 · Cited by 101
Self-citationOptogenetic in vivocell manipulation in KillerRed-expressing zebrafish transgenics
Teh, C., Chudakov, D. M., Poon, K., Mamedov, I. Z., Sek, J.-Y., Shidlovskiy, K. M., Lukyanov, S., & Korzh, V. P. (2010) · BMC Developmental Biology · doi:10.1186/1471-213x-10-110 · Cited by 97
Growth cones stall and collapse during axon outgrowth in Caenorhabditis elegans
Knobel, K. M., Jørgensen, E. M., & Bastiani, M. J. (1999) · Development · doi:10.1242/dev.126.20.4489 · Cited by 93
Yamagata, K., Suetsugu, R., & Wakayama, T. (2009) · Journal of Reproduction and Development · doi:10.1262/jrd.20166 · Cited by 92
Excitation Light Dose Engineering to Reduce Photo-bleaching and Photo-toxicity
Boudreau, C. G., Wee, T.-L., Duh, Y.-R., Couto, M. P., Hassani‐Ardakani, K., & Brown, C. M. (2016) · Scientific Reports · doi:10.1038/srep30892 · Cited by 91
Light exposure and cell viability in fluorescence microscopy
Schneckenburger, H., Weber, P., Wagner, M., Schickinger, S., Richter, V., Bruns, T., Strauß, W. S. L., & Wittig, R. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2011.03576.x · Cited by 90
Jemielita, M., Taormina, M. J., DeLaurier, A., Kimmel, C. B., & Parthasarathy, R. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200144 · Cited by 89
Points, Pixels, and Gray Levels: Digitizing Image Data
Pawley, J. B. (2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2_4 · Cited by 88
The influence of sublethal blue light exposure on human RPE cells.
(2009) · PubMed Central · Cited by 88
Imaging the division process in living tissue culture cells
Khodjakov, A. L., & Rieder, C. L. (2005) · Methods · doi:10.1016/j.ymeth.2005.07.007 · Cited by 87
Intrinsic Indicator of Photodamage during Label-Free Multiphoton Microscopy of Cells and Tissues
Galli, R., Uckermann, O., Andresen, E. F., Geiger, K. D., Koch, E., Schackert, G., Steiner, G. R., & Kirsch, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110295 · Cited by 86
Independent modes of ganglion cell translocation ensure correct lamination of the zebrafish retina
Icha, J., Kunath, C., Rocha-Martins, M., & Norden, C. (2016) · The Journal of Cell Biology · doi:10.1083/jcb.201604095 · Cited by 84
Self-citationDébarre, D., Olivier, N., Supatto, W., & Beaurepaire, E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104250 · Cited by 80
Comparison of Widefield/Deconvolution and Confocal Microscopy for Three-Dimensional Imaging
Shaw, P. (2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2_23 · Cited by 73
Blue Light Inhibits Mitosis in Tissue Culture Cells
Горгидзе, Л. А., Oshemkova, S. A., & Vorobjev, I. A. (1998) · Bioscience Reports · doi:10.1023/a:1020104914726 · Cited by 72
Wagner, M., Weber, P., Bruns, T., Strauß, W. S. L., Wittig, R., & Schneckenburger, H. (2010) · International Journal of Molecular Sciences · doi:10.3390/ijms11030956 · Cited by 67
Assessment of tissue heating under tunable near-infrared radiation
Bixler, J. N., Hokr, B. H., Denton, M. L., Noojin, G. D., Shingledecker, A. D., Beier, H. T., Thomas, R. J., Rockwell, B. A., & Yakovlev, V. V. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.070501 · Cited by 67
Anti-Fading Media for Live Cell GFP Imaging
Bogdanov, A. M., Kudryavtseva, E. I., & Lukyanov, K. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0053004 · Cited by 65
Triplet-relaxation microscopy with bunched pulsed excitation
Donnert, G., Eggeling, C., & Hell, S. W. (2009) · Photochemical & Photobiological Sciences · doi:10.1039/b903357m · Cited by 62
Recent progress in expanding the chemiluminescent toolbox for bioimaging
Suzuki, K., & Nagai, T. (2017) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2017.04.001 · Cited by 60
Live Cell Imaging: Assessing the Phototoxicity of 488 and 546 nm Light and Methods to Alleviate it
Douthwright, S., & Sluder, G. (2016) · Journal of Cellular Physiology · doi:10.1002/jcp.25588 · Cited by 58
Measuring structural dynamics of chromosomes in living cells by fluorescence microscopy
Mora‐Bermúdez, F., & Ellenberg, J. (2006) · Methods · doi:10.1016/j.ymeth.2006.07.035 · Cited by 54
Imaging in developmental biology : a laboratory manual
Sharpe, J. A., & Wong, R. (2011) · Cited by 37
Total Internal Reflection Fluorescence MicroscopyPreprint
Yıldız, A., & Vale, R. D. (2015) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top086348 · Cited by 34
Fast Fluorescence Microscopy with Light Sheets
Daetwyler, S., & Huisken, J. (2016) · Biological Bulletin · doi:10.1086/689588 · Cited by 32
Fluorescent proteins for quantitative microscopy
Shaner, N. C. (2014) · Methods in cell biology · doi:10.1016/b978-0-12-420138-5.00006-9 · Cited by 30
Shafirovich, V., Dourandin, A., Luneva, N. P., Singh, C., Kirigin, F. K., & Geacintov, N. E. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb03285.x · Cited by 28
Penjweini, R., LOEW, H. G., Hamblin, M. R., & Kratky, K. W. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2011.03555.x · Cited by 19
Cytoskeleton Methods and Protocols
Gavin, R. H. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-3124-8 · Cited by 18
Pestov, D., Andegeko, Y., Lozovoy, V. V., & Dantus, M. M. (2010) · Journal of Optics · doi:10.1088/2040-8978/12/8/084006 · Cited by 18
Minimizing photodecomposition of flavin adenine dinucleotide fluorescence by the use of pulsed LEDs
Rösner, J., Liotta, A., Angamo, E. A., Spies, C., Heinemann, U., & KOVÁCS, R. (2016) · Journal of Microscopy · doi:10.1111/jmi.12436 · Cited by 15
Contractile dynamics change before morphological cues during fluorescence illumination
Knoll, S. G., Ahmed, W., & Saif, T. A. (2015) · Scientific Reports · doi:10.1038/srep18513 · Cited by 15
DeadNet: Identifying Phototoxicity from Label-free Microscopy Images of Cells using Deep ConvNetsPreprint
Richmond, D., Jost, A. P.-T., Lambert, T. J., et al. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1701.06109 · Cited by 8
Visualization can be harmful for live cells
Tárnok, A. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22307 · Cited by 6
Spatially-controlled illumination microscopy
Krishnaswami, V., Noorden, C. J. F. V., Manders, E. M. M., & Hoebe, R. A. (2016) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583516000135 · Cited by 6
Cited by
Morphodynamics of human early brain organoid development
Jain, A., Gut, G., Sanchis-Calleja, F., Tschannen, R., He, Z., Luginbühl, N., Zenk, F., Chrisnandy, A., Streib, S., Harmel, C., et al. (2025) · Nature · doi:10.1038/s41586-025-09151-3 · Cited by 73
Present Application and Perspectives of Organoid Imaging Technology
Fei, K., Zhang, J., Yuan, J., & Xiao, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030121 · Cited by 65
Sønstevold, L., Czerkies, M., Escobedo-Cousin, E., Blonski, S., & Vereshchagina, E. (2023) · Micromachines · doi:10.3390/mi14030532 · Cited by 25
Metadata
- Authors
- Icha, J., Weber, M., Waters, J. C., & Norden, C.
- Venue
- BioEssays
- Publisher
- Wiley
- Published
- 2017-07-27
- Volume
- 39
- Issue
- 8
- ISSN
- 0265-9247 (ISSN-L)
- 1521-1878
- OpenAlex
- W2740811129
- Cited by
- 622
- References
- 98
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.