Stimuli‐responsive delivery of therapeutics for diabetes treatment
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Diabetic therapeutics, including insulin and glucagon‐like peptide 1 (GLP‐1), are essential for diabetic patients to regulate blood glucose levels. However, conventional treatments that are based on subcutaneous injections are often associated with poor glucose control and a lack of patient compliance. In this review, we focus on the different stimuli‐responsive systems to deliver therapeutics for diabetes treatment to improve patient comfort and prevent complications. Specifically, the pH‐responsive systems for oral drug delivery are introduced first. Then, the closed‐loop glucose‐responsive systems are summarized based on different glucose‐responsive moieties, including glucose oxidase, glucose binding protein, and phenylboronic acid. Finally, the on‐demand delivery systems activated by external remote triggers are also discussed. We conclude by discussing advantages and limitations of current strategies, as well as future opportunities and challenges in this area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Emerging Risk Factors Collaboration (2010) · The Lancet · doi:10.1016/s0140-6736(10)60484-9 · Cited by 5,125
Type 2 diabetes as an inflammatory disease
Donath, M. Y., & Shoelson, S. E. (2011) · Nature Reviews Immunology · doi:10.1038/nri2925 · Cited by 3,737 · cited 2×
“However, patients with type 2 diabetes are characterized by insulin resistance, which means their response to insulin is blunted, thus causing hyperglycemia.(6) Gestational”
BackgroundBiology of Incretins: GLP-1 and GIP
Baggio, L. L., & Drucker, D. J. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.03.054 · Cited by 3,639 · cited 2×
“However, the half-life time of GLP-1 is relatively short (1–2 min), since it is quickly degraded by the enzyme DDP4.(43,44) Thus, the DPP4 inhibitor was co-delivered with GLP-1 to enhance the therapy efficiency in this system.”
BackgroundInfluentialThe Physiology of Glucagon-like Peptide 1
Holst, J. J. (2007) · Physiological Reviews · doi:10.1152/physrev.00034.2006 · Cited by 3,371
Type 2 diabetes: principles of pathogenesis and therapy
Stumvoll, M., Goldstein, B. J., & van Haeften, T. W. (2005) · The Lancet · doi:10.1016/s0140-6736(05)61032-x · Cited by 2,662
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · cited 1×
“Integration with a grapheme-based electrochemical sensor lead to a thermo-responsive microneedle-array patch, which was developed for real-time glucose control by Kim and coworkers.(127) The graphene doped with gold when combined with a gold mesh showed an improved electrochemical activity to satisfy the requirements…”
BackgroundOvercoming the challenges in administering biopharmaceuticals: Formulation and delivery strategies
Mitragotri, S., Burke, P. A., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4363 · Cited by 1,702
Type 1 diabetes: new perspectives on disease pathogenesis and treatment
Atkinson, M. A., & Eisenbarth, G. S. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05415-0 · Cited by 1,491
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349 · cited 1×
“Based on thermal-responsive polymers such as poly(NIPAM) (PNIPAAm), several temperature-triggered insulin delivery systems have been developed.(124,125) Lima et al.”
BackgroundMeasurement of gastrointestinal pH profiles in normal ambulant human subjects
Evans, D. F., Pye, G., Bramley, R., Clark, A. G., Dyson, T. J., & Hardcastle, J. D. (1988) · Gut · doi:10.1136/gut.29.8.1035 · Cited by 1,240 · cited 1×
“the stomach and various digestive enzymes in the gastrointestinal tract may degrade insulin, leading to low efficacy of therapy.(18,19) To enhance”
BackgroundEpidemiology of gestational diabetes mellitus and its association with Type 2 diabetes
Ben‐Haroush, A., Yogev, Y., & Hod, M. (2004) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.00985.x · Cited by 856
Recent advances of cocktail chemotherapy by combination drug delivery systems
Hu, Q., Sun, W., Wang, C., & Gu, Z. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.10.022 · Cited by 625
Self-citationStimuli-responsive nanomaterials for therapeutic protein delivery
Lu, Y., Sun, W., & Gu, Z. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.08.015 · Cited by 415
Self-citationFully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315 · cited 1×
“The insulin infusion rate can be adjusted in response to the BGL signal from the glucose sensor in these wireless, portable, and wearable systems.(49,50) Conversely, synthetic smart insulin delivery systems have been heavily explored to achieve closed-loop delivery from the use of material design and formulation engin…”
MethodInsulin-pump therapy for type 1 diabetes mellitus
Pickup, J. C. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1113948 · Cited by 270 · cited 1×
“One notable example is the electronic/mechanical insulin pump, which consists of a continuous glucose sensor and an external insulin infusion pump.(47,48) The insulin infusion rate can be adjusted in response to the BGL signal from the glucose sensor in these wireless, portable, and wearable systems.”
BackgroundStretch-Triggered Drug Delivery from Wearable Elastomer Films Containing Therapeutic Depots
Di, J., Yao, S., Ye, Y., Cui, Z., Yu, J., Ghosh, T. K., Zhu, Y., & Gu, Z. (2015) · ACS Nano · doi:10.1021/acsnano.5b03975 · Cited by 253 · cited 1×
“Recently, Gu and coworkers designed a stretch-triggered insulin delivery system using wearable elastomer films containing therapeutic depots.(132) The microgel depots consisting of insulin loaded NPs were embedded about halfway inside the elastomeric film.”
BackgroundSelf-citationMultinational Home Use of Closed-Loop Control Is Safe and Effective
Anderson, S. M., Raghinaru, D., Pinsker, J. E., Boscari, F., Renard, E., Buckingham, B. A., Nimri, R., Doyle, F. J., Brown, S. A., Keith-Hynes, P., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2468 · Cited by 120 · cited 1×
“The insulin infusion rate can be adjusted in response to the BGL signal from the glucose sensor in these wireless, portable, and wearable systems.(49,50) Conversely, synthetic smart insulin delivery systems have been heavily explored to achieve closed-loop delivery from the use of material design and formulation engin…”
Method
Cited by
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604
Self-citationDrug delivery systems for programmed and on-demand release
Davoodi, P., Lee, L. Y., Xu, Q., Sunil, V., Sun, Y., Soh, S., & Wang, C.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.002 · Cited by 353
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Self-citationCore–Shell Microneedle Gel for Self-Regulated Insulin Delivery
Wang, J., Ye, Y., Yu, J., Kahkoska, A. R., Zhang, X., Wang, C., Sun, W., Corder, R. D., Chen, Z., Khan, S. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08152 · Cited by 299
Self-citationGlucose‐Responsive Insulin and Delivery Systems: Innovation and Translation
Wang, J., Wang, Z., Yu, J., Kahkoska, A. R., Buse, J. B., & Gu, Z. (2020) · Advanced Materials · doi:10.1002/adma.201902004 · Cited by 295
Self-citation
Metadata
- Authors
- Yu, J., Zhang, Y., Bomba, H., & Gu, Z.
- Venue
- Bioengineering & Translational Medicine
- Publisher
- Wiley
- Published
- 2016-09
- Volume
- 1
- Issue
- 3
- Pages
- 323-337
- ISSN
- 2380-6761 (ISSN-L)
- OpenAlex
- W2523536075
- Cited by
- 109
- References
- 17
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.