Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The use of commercial carbon fibres (CCF) to build wearable potentiometric sensors for the real‐time monitoring of sodium levels in sweat during exercise is presented. CCF are an attractive substrate for building wearable electrochemical sensors because of their good electrical conductivity, chemical inertness, flexibility and mechanical resilience. In the first part of this work, the analytical performance of these novel potentiometric ion‐selective electrodes made with CCFs is presented. Then, through the incorporation of a solid‐contact reference electrode, the development of a complete miniaturized potentiometric cell with a Nernstian response (59.2±0.6 mV/log [Na+], N=4) is obtained. Finally, the cell is integrated into a wearable patch and attached onto the skin of an athlete. The analytical characterization of the wearable patch shows a near‐Nernstian response (55.9±0.8 mV/log [Na+], N=3) for sodium levels from 10−3 M to 10−1 M in artificial sweat, well within the physiological range of interest. The device shows low noise levels and very good stability (−0.4±0.3 mV ⋅ h−1). To improve the usability of the sensor in real scenarios, a calibration‐free approach is also explored. This platform opens new and attractive avenues for the generation of meaningful personalized physiological information that could be applied – among many other fields – in sports, nutrition and healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Fluid and fuel intake during exercise
Coyle, E. F. (2004) · Journal of Sports Sciences · doi:10.1080/0264041031000140545 · Cited by 423
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Self-citationBandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Baker, L. B., Stofan, J. R., Hamilton, A. A., & Horswill, C. A. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00197.2009 · Cited by 189
Sodium ion concentration vs. sweat rate relationship in humans
Buono, M. J., Ball, K. D., & Kolkhorst, F. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00015.2007 · Cited by 186
Dehydration and rehydration in competative sport
Maughan, R. J., & Shirreffs, S. M. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01207.x · Cited by 167
Preparation of all solid-state potentiometric ion sensors with polymer-CNT composites
Zhu, J., Qin, Y., & Zhang, Y. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.06.025 · Cited by 98
An integrated sensing and wireless communications platform for sensing sodium in sweat
Matzeu, G., O'Quigley, C., McNamara, E., Zuliani, C., Fay, C., Glennon, T., & Diamond, D. (2016) · Analytical Methods · doi:10.1039/c5ay02254a · Cited by 80
Cited by
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Metadata
- Authors
- Parrilla, M., Ferré, J., Guinovart, T., & Andrade, F. J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2016-04-14
- Volume
- 28
- Issue
- 6
- Pages
- 1267-1275
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2340438937
- Cited by
- 122
- References
- 14
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.