CoChat

‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content

Open access
Glennon, Tom, O'Quigley, Conor, McCaul, Margaret, Matzeu, Giusy, Beirne, Stephen, Wallace, Gordon G., Stroiescu, Florin, O'Mahoney, Niamh, White, Paddy, Diamond, Dermot · 2016 · Electroanalysis
Cited by 147

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

A platform for harvesting and analysing the sodium content of sweat in real time is presented. One is a ‘watch’ format in which the sampling and fluidic system, electrodes, circuitry and battery are arranged vertically, while in the other ‘pod’ format, the electronics and battery components, and the fluidics electrodes are arranged horizontally. The platforms are designed to be securely attached to the skin using a velcro strap. Sweat enters into the device through a sampling orifice and passes over solid‐state sodium‐selective and reference electrodes and into a storage area containing a high capacity adsorbent material. The liquid movement is entirely driven by capillary action, and the flow rate through the device can be mediated through variation of the width of a fluidic channel linking the electrodes to the sample storage area. Changing the width dimension through 750, 500 and 250 µm produces flow rates of 38.20, 21.48 and 6.61 µL/min, respectively. Variation of the sweat uptake rate and the storage volume capacity enables the duration of usage to be varied according to the needs of the user. The devices can be easily disassembled to replace the electrodes and the high capacity adsorbant material. The storage sweat is available for subsequent measurement of the total volume of sweat harvested and the average concentration of sodium over the period of use. Signals generated by the electrodes are passed to a custom designed electronics board with high input impedance to accurately capture the voltage. The real‐time data is transmitted wirelessly using incorporated Bluetooth circuitry to a remote basestation (laptop, mobile phone, tablet) for data visualization and storage in standard formats. Results obtained during trials over a period of ca. 30 minutes controlled exercise are consistent with previously published data, showing a gradual relatively slow increase of the sodium concentration in the sweat during this period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elan.201600106

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 147

Metadata

Authors
Glennon, T., O'Quigley, C., McCaul, M., Matzeu, G., Beirne, S., Wallace, G. G., Stroiescu, F., O'Mahoney, N., White, P., & Diamond, D.
Venue
Electroanalysis
Publisher
Wiley
Published
2016-04-27
Volume
28
Issue
6
Pages
1283-1289
ISSN
  • 1040-0397 (ISSN-L)
  • 1521-4109
OpenAlex
W2342406716
Cited by
147
References
7
FWCI
7.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content. https://app.cochat.ai/papers/10.1002/elan.201600106
The paper
Glennon, T., O'Quigley, C., McCaul, M., Matzeu, G., Beirne, S., Wallace, G. G., Stroiescu, F., O'Mahoney, N., White, P., & Diamond, D. (2016). ‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content. Electroanalysis. https://doi.org/10.1002/elan.201600106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.