‘SWEATCH’: A Wearable Platform for Harvesting and Analysing Sweat Sodium Content
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A platform for harvesting and analysing the sodium content of sweat in real time is presented. One is a ‘watch’ format in which the sampling and fluidic system, electrodes, circuitry and battery are arranged vertically, while in the other ‘pod’ format, the electronics and battery components, and the fluidics electrodes are arranged horizontally. The platforms are designed to be securely attached to the skin using a velcro strap. Sweat enters into the device through a sampling orifice and passes over solid‐state sodium‐selective and reference electrodes and into a storage area containing a high capacity adsorbent material. The liquid movement is entirely driven by capillary action, and the flow rate through the device can be mediated through variation of the width of a fluidic channel linking the electrodes to the sample storage area. Changing the width dimension through 750, 500 and 250 µm produces flow rates of 38.20, 21.48 and 6.61 µL/min, respectively. Variation of the sweat uptake rate and the storage volume capacity enables the duration of usage to be varied according to the needs of the user. The devices can be easily disassembled to replace the electrodes and the high capacity adsorbant material. The storage sweat is available for subsequent measurement of the total volume of sweat harvested and the average concentration of sodium over the period of use. Signals generated by the electrodes are passed to a custom designed electronics board with high input impedance to accurately capture the voltage. The real‐time data is transmitted wirelessly using incorporated Bluetooth circuitry to a remote basestation (laptop, mobile phone, tablet) for data visualization and storage in standard formats. Results obtained during trials over a period of ca. 30 minutes controlled exercise are consistent with previously published data, showing a gradual relatively slow increase of the sodium concentration in the sweat during this period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia
Smith, C. J., & Havenith, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1744-8 · Cited by 375
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Self-citationAn integrated sensing and wireless communications platform for sensing sodium in sweat
Matzeu, G., O'Quigley, C., McNamara, E., Zuliani, C., Fay, C., Glennon, T., & Diamond, D. (2016) · Analytical Methods · doi:10.1039/c5ay02254a · Cited by 80
Self-citation
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Self-citationEvolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
“Various materials have been used as working electrodes, such as noble metal (Au and Ag) (20–22), metallic oxides (23, 24), graphene (25, 26), and carbon black (27).”
BackgroundRecent advances in wearable sensors for animal health management
Neethirajan, S. (2017) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.11.004 · Cited by 502
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
“In conventional forms, such sensors use bulk electrodes and data acquisition electronics in rigid and planar formats (44, 78) that are poorly suited for skin-integrated, continuous monitoring.”
BackgroundLiu, Y., Wang, H., Zhao, W., Zhang, M., Qin, H., & Xie, Y. (2018) · Sensors · doi:10.3390/s18020645 · Cited by 387
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Zdrachek, E., & Bakker, E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04681 · Cited by 338
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Wireless chemical sensors and biosensors: A review
Kassal, P., Steinberg, M. D., & Steinberg, I. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.074 · Cited by 308
A wearable patch for continuous monitoring of sweat electrolytes during exertion
Alizadeh, A., Burns, A., Lenigk, R., Gettings, R., Ashe, J., Porter, A., McCaul, M., Barrett, R., Diamond, D., White, P., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00510a · Cited by 180
Self-citationWang, S., Wu, Y., Gu, Y., Li, T., Luo, H., Li, L.-H., Bai, Y., Li, L., Liu, L., Cao, Y., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01560 · Cited by 174
Lee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153
Wearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces
Shay, T., Dickey, M. D., & Velev, O. D. (2017) · Lab on a Chip · doi:10.1039/c6lc01486k · Cited by 71
Metadata
- Authors
- Glennon, T., O'Quigley, C., McCaul, M., Matzeu, G., Beirne, S., Wallace, G. G., Stroiescu, F., O'Mahoney, N., White, P., & Diamond, D.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2016-04-27
- Volume
- 28
- Issue
- 6
- Pages
- 1283-1289
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2342406716
- Cited by
- 147
- References
- 7
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.