The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Surface modification of poly(dimethylsiloxane) microchannels
Abstract
This review looks at the efforts that are being made to modify the surface of poly(dimethylsiloxane) (PDMS) microchannels, in order to enhance applicability in the field of microfluidics. Many surface modifications of PDMS have been performed for electrophoretic separations, but new modifications are being done for emerging applications such as heterogeneous immunoassays and cell‐based bioassays. These new modification techniques are powerful because they impart biospecificity to the microchannel surfaces and reduce protein adsorption. Most of these applications require the use of aqueous or polar solvents, which makes surface modification a very important topic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuzzy Nanoassemblies: Toward Layered Polymeric Multicomposites
Decher, G. (1997) · Science · doi:10.1126/science.277.5330.1232 · Cited by 10,054
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Decher, G., Hong, J. D., & Schmitt, J. (1992) · Thin Solid Films · doi:10.1016/0040-6090(92)90417-a · Cited by 2,821
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Cited by
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Microcontact Printing: Limitations and Achievements
Perl, A., Reinhoudt, D. N., & Huskens, J. (2009) · Advanced Materials · doi:10.1002/adma.200801864 · Cited by 447
Anti-fouling Coatings of Poly(dimethylsiloxane) Devices for Biological and Biomedical Applications
Zhang, H., & Chiao, M. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0029-4 · Cited by 415
Enhancement of Triboelectric Charge Density by Chemical Functionalization
Liu, Y., Mo, J., Fu, Q., Lu, Y., Zhang, N., Wang, S., & Nie, S. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004714 · Cited by 386
Surface modification for PDMS‐based microfluidic devices
Zhou, J., Khodakov, D. A., Ellis, A. V., & Voelcker, N. H. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100482 · Cited by 344
Magnetically Actuated Nanorod Arrays as Biomimetic Cilia
Evans, E. E., Shields, A. R., Carroll, R. L., Washburn, S., Falvo, M. R., & Superfine, R. (2007) · Nano Letters · doi:10.1021/nl070190c · Cited by 304
Gökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Bartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Ho, T. M., Razzaghi, A., Ramachandran, A., & Mikkonen, K. S. (2022) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102541 · Cited by 253
Micropatterns of Matrigel for three-dimensional epithelial cultures
Sodunke, T. R., Turner, K. K., Caldwell, S. A., McBride, K. W., Reginato, M. J., & Noh, H. “. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.021 · Cited by 109
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010) · Analytical Chemistry · doi:10.1021/ac101870s · Cited by 104
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
“[30,160] mitigate these problems but often at the cost”
BackgroundA microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Ereifej, E. S., Cheng, M. M.-C., Mao, G., & VandeVord, P. J. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.04.023 · Cited by 19
Metadata
- Authors
- Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 24
- Issue
- 21
- Pages
- 3607-3619
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2042920136
- Cited by
- 551
- References
- 28
- FWCI
- 20.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.