Power Vectors: An Application of Fourier Analysis to the Description and Statistical Analysis of Refractive Error
The DOI matches its OpenAlex record.
Abstract
The description of sphero-cylinder lenses is approached from the viewpoint of Fourier analysis of the power profile. It is shown that the familiar sine-squared law leads naturally to a Fourier series representation with exactly three Fourier coefficients, representing the natural parameters of a thin lens. The constant term corresponds to the mean spherical equivalent (MSE) power, whereas the amplitude and phase of the harmonic correspond to the power and axis of a Jackson cross-cylinder (JCC) lens, respectively. Expressing the Fourier series in rectangular form leads to the representation of an arbitrary sphero-cylinder lens as the sum of a spherical lens and two cross-cylinders, one at axis 0 degree and the other at axis 45 degrees. The power of these three component lenses may be interpreted as (x,y,z) coordinates of a vector representation of the power profile. Advantages of this power vector representation of a sphero-cylinder lens for numerical and graphical analysis of optometric data are described for problems involving lens combinations, comparison of different lenses, and the statistical distribution of refractive errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Atropine for the Treatment of Childhood Myopia
Chua, W.-H., Balakrishnan, V., Chan, Y.-H., Tong, L., Ling, Y., Quah, B.-L., & Tan, D. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.062 · Cited by 695
Thibos, L. N., Hong, X., Bradley, A., & Cheng, X. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002329 · Cited by 622
Self-citationGwiazda, J., Hyman, L., Hussein, M., Everett, D., Norton, T. T., Kurtz, D., Leske, M. C., Manny, R., Marsh-Tootle, W., & Scheiman, M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0816 · Cited by 595
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Self-citationPower vector analysis of the optical outcome of refractive surgery
Thibos, L. N., & Horner, D. (2001) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(00)00797-5 · Cited by 477
Self-citationEffect of Dual-Focus Soft Contact Lens Wear on Axial Myopia Progression in Children
Anstice, N. S., & Phillips, J. R. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.10.035 · Cited by 422
Walline, J. J., Walker, M. K., Mutti, D. O., Jones-Jordan, L. A., Sinnott, L. T., Giannoni, A. G., Bickle, K. M., Schulle, K. L., Nixon, A., Pierce, G. E., et al. (2020) · JAMA · doi:10.1001/jama.2020.10834 · Cited by 304
A new non-contact optical device for ocular biometry
Santodomingo-Rubido, J. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.4.458 · Cited by 294
Peripheral refraction along the horizontal and vertical visual fields in myopia
Atchison, D. A., Pritchard, N., & Schmid, K. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.10.023 · Cited by 285
Multifocal Contact Lens Myopia Control
Walline, J. J., Greiner, K. L., McVey, M. E., & Jones-Jordan, L. A. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000036 · Cited by 285
Peripheral Refraction in Myopic Children Wearing Orthokeratology and Gas-Permeable Lenses
Kang, P., & Swarbrick, H. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31820f16fb · Cited by 236
Peripheral Refraction in Myopic Patients After Orthokeratology
Queirós, A., González-Méijome, J. M., Jorge, J., Villa-Collar, C., & Gutiérrez, A. R. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181d951f7 · Cited by 200
Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500
Sheppard, A. L., & Davies, L. N. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00701.x · Cited by 199
Clinical Evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K Autorefractor
Davies, L. N., Mallen, E. A. H., Wolffsohn, J. S., & GILMARTIN, A. B. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01640.x · Cited by 198
The relationship between anisometropia and amblyopia
Barrett, B. T., Bradley, A., & Candy, T. R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.05.001 · Cited by 196
Astigmatism and the development of myopia in children
Gwiazda, J., Grice, K., Held, R., McLellan, J., & Thorn, F. (2000) · Vision Research · doi:10.1016/s0042-6989(99)00237-0 · Cited by 195
A Randomized Trial of the Effects of Rigid Contact Lenses on MyopiaProgression
Walline, J. J. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.12.1760 · Cited by 185
Peripheral Refraction in Orthokeratology Patients
CHARMAN, W. N., MOUNTFORD, J., ATCHISON, D. A., & MARKWELL, E. L. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000232840.66716.af · Cited by 185
IMI – Clinical Myopia Control Trials and Instrumentation Report
Wolffsohn, J. S., Kollbaum, P. S., Berntsen, D. A., Atchison, D. A., Benavente, A., Bradley, A., Buckhurst, H., Collins, M., Fujikado, T., Hiraoka, T., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25955 · Cited by 184
Diurnal Variation of Corneal Shape and Thickness
Read, S. A., & Collins, M. J. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181981b7e · Cited by 182
Theoretical performance of progressive addition lenses with poorly measured individual parameters
Pascual, E., Gómez‐Pedrero, J. A., & Alonso, J. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13088 · Cited by 11
Optical performance of progressive addition lenses (PALs) with astigmatic prescription
De Lestrange-Anginieur, E., & Kee, C. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-82697-0 · Cited by 9
Oh, S.-K., Kim, J.-M., Yoon, G.-Y., Yoo, Y.-S., & Kim, D. Y. (2024) · Photonics · doi:10.3390/photonics11040332 · Cited by 1
Metadata
- Authors
- Thibos, L. N., WHEELER, W., & Horner, D. G.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 1997-06
- Volume
- 74
- Issue
- 6
- Pages
- 367-375
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2012640979
- Cited by
- 1,238
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.