New Design Principles for Visual Acuity Letter Charts
The DOI matches its OpenAlex record.
Abstract
This paper intoduces new principles for the design and use of letter charts for the measurement of visual acuity. It is advocated that the test task should be essentially the same at each size level on the chart. Such standardization of the test task requires the use of letters of equal legibility, the same number of letters on each row, and uniform between-letter and between-row spacing. It is also advocated that, combined with the test task standardization, there should be a logarithmic progression of letter size. Charts incorporating these design features have been made. These charts facilitate the use of nonstandard testing distances which might be used when there is low visual acuity, when examination room layout prevents testing at the standard distance, or when it is necessary to validate visual acuity scores or detect malingering. Adjusting the visual acuity score according to the chosen testing distance is simplified by the use of logarithmic scaling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Risk Factors for Hip Fracture in White Women
Cummings, S. R., Nevitt, M. C., Browner, W. S., Stone, K., Fox, K. M., Ensrud, K. E., Cauley, J., Black, D., & Vogt, T. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503233321202 · Cited by 3,595
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
Self-citationProper Method for Calculating Average Visual Acuity
Holladay, J. T. (1997) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19970701-16 · Cited by 1,090
Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L., & Bach, M. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0981 · Cited by 994
Contrast sensitivity throughout adulthood
Owsley, C., Sekuler, R., & Siemsen, D. (1983) · Vision Research · doi:10.1016/0042-6989(83)90210-9 · Cited by 821
Older Women with Diabetes Have an Increased Risk of Fracture: A Prospective Study
Schwartz, A. V. (2001) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.86.1.32 · Cited by 789
Ranibizumab versus Bevacizumab to Treat Neovascular Age-related Macular Degeneration
Chakravarthy, U., Harding, S. P., Rogers, C. A., Downes, S. M., Lotery, A. J., Wordsworth, S., & Reeves, B. C. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.04.015 · Cited by 781
Orwoll, E., Blank, J. B., Barrett-Connor, E., Cauley, J., Cummings, S., Ensrud, K., Lewis, C., Cawthon, P. M., Marcus, R., Marshall, L. M., et al. (2005) · Contemporary Clinical Trials · doi:10.1016/j.cct.2005.05.006 · Cited by 765
Chakravarthy, U., Harding, S. P., Rogers, C. A., Downes, S. M., Lotery, A. J., Culliford, L. A., & Reeves, B. C. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61501-9 · Cited by 748
Holladay, J. T. (2004) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.01.014 · Cited by 686
Relation of Visual Function to Retinal Nerve Fiber Layer Thickness in Multiple Sclerosis
FISHER, J., JACOBS, D., MARKOWITZ, C., GALETTA, S., VOLPE, N., NANOSCHIAVI, M., BAIER, M., FROHMAN, E., WINSLOW, H., & FROHMAN, T. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.040 · Cited by 658
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Brody, B. L., Gamst, A. C., Williams, R. A., Smith, A. R., Lau, P. W., Dolnak, D., Rapaport, M. H., Kaplan, R. M., & Brown, S. I. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00754-0 · Cited by 581
Older Women With Diabetes Have a Higher Risk of Falls
Schwartz, A. V., Hillier, T. A., Sellmeyer, D. E., Resnick, H. E., Gregg, E., Ensrud, K. E., Schreiner, P. J., Margolis, K. L., Cauley, J. A., Nevitt, M. C., et al. (2002) · Diabetes Care · doi:10.2337/diacare.25.10.1749 · Cited by 576
Is grip strength a useful single marker of frailty?
Syddall, H., Cooper, C., Martin, F., Briggs, R., & Aihie Sayer, A. (2003) · Age and Ageing · doi:10.1093/ageing/afg111 · Cited by 564
NOVEL METHOD FOR ANALYZING SNELLEN VISUAL ACUITY MEASUREMENTS
Gregori, N. Z., Feuer, W., & Rosenfeld, P. J. (2010) · Retina · doi:10.1097/iae.0b013e3181d87e04 · Cited by 524
Is Diabetes Associated With Cognitive Impairment and Cognitive Decline Among Older Women?
Gregg, E. W. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.2.174 · Cited by 521
Lin, M. Y., Gutierrez, P. R., Stone, K. L., Yaffe, K., Ensrud, K. E., Fink, H. A., Sarkisian, C. A., Coleman, A. L., & Mangione, C. M. (2004) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2004.52554.x · Cited by 438
The Psychosocial Impact of Macular Degeneration
Williams, R. A. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.4.514 · Cited by 423
Musch, D. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90147-1 · Cited by 402
Harwood, R. H. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.049478 · Cited by 395
Arora, N. K., Nair, M. K. C., Gulati, S., Deshmukh, V., Mohapatra, A., Mishra, D., Patel, V., Pandey, R. M., Das, B. C., Divan, G., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002615 · Cited by 342
Bastawrous, A., Rono, H. K., Livingstone, I. A. T., Weiss, H. A., Jordan, S., Kuper, H., & Burton, M. J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.1468 · Cited by 339
Diabetes and incidence of functional disability in older women
Gregg, E. W., Mangione, C. M., Cauley, J. A., Thompson, T. J., Schwartz, A. V., Ensrud, K. E., Nevitt, M. C., & for the Study of Osteoporotic Fractures Research Group (2002) · Diabetes Care · doi:10.2337/diacare.25.1.61 · Cited by 333
Stewart, C. E., Moseley, M. J., Stephens, D. A., & Fielder, A. R. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0250 · Cited by 327
Retinal Vasculitis and Intraocular Inflammation after Intravitreal Injection of Brolucizumab
Baumal, C. R., Spaide, R. F., Vajzovic, L., Freund, K. B., Walter, S. D., John, V., Rich, R., Chaudhry, N., Lakhanpal, R. R., Oellers, P. R., et al. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.04.017 · Cited by 312
Vision and cognition in Alzheimer’s disease
Rizzo, M. (2000) · Neuropsychologia · doi:10.1016/s0028-3932(00)00023-3 · Cited by 308
Corneal Aberrations and Visual Performance After Radial Keratotomy
Applegate, R. A., Howland, H. C., Sharp, R. P., Cottingham, A. J., & Yee, R. W. (1998) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19980701-05 · Cited by 307
NEW VISUAL ACUITY TEST FOR PRE‐SCHOOL CHILDREN
HYVÄRINEN, L., NÄSÄNEN, R., & LAURINEN, P. (1980) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1980.tb08291.x · Cited by 288
The epidemiology of cataract in Australia
McCarty, C. A., Mukesh, B. N., Fu, C. L., & Taylor, H. R. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00218-4 · Cited by 276
Mehta, H., Tufail, A., Daien, V., Lee, A. Y., Nguyen, V., Ozturk, M., Barthelmes, D., & Gillies, M. C. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.12.002 · Cited by 265
How Sensitive to Clinical Change are ETDRS logMAR Visual Acuity Measurements?
Rosser, D. A., Cousens, S. N., Murdoch, I. E., Fitzke, F. W., & Laidlaw, D. A. H. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1100 · Cited by 264
Preferred Retinal Locus Development in Patients with Macular Disease
Crossland, M. D., Culham, L. E., Kabanarou, S. A., & Rubin, G. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.03.027 · Cited by 263
Correlates of Impaired Function in Older Women
Ensrud, K. E., Nevitt, M. C., Yunis, C., Cauley, J. A., Seeley, D. G., Fox, K. M., & Cummings, S. R. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb04968.x · Cited by 262
Corneal First Surface Optical Aberrations and Visual Performance
Applegate, R. A., Hilmantel, G., Howland, H. C., Tu, E. Y., Starck, T., & Zayac, E. J. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000901-04 · Cited by 256
Functional Status and Quality of Life Measurement Among Ophthalmic Patients
Scott, I. U. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090150059023 · Cited by 253
Quality of life in keratoconus
Kymes, S. M., Walline, J. J., Zadnik, K., & Gordon, M. O. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.04.031 · Cited by 253
Validity and reliability of visual acuity measurements
Lovie‐Kitchin, J. E. (1988) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1988.tb01170.x · Cited by 249
Transepithelial corneal collagen crosslinking: Bilateral study
Filippello, M., Stagni, E., & O’Brart, D. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.08.030 · Cited by 248
Visual acuity testing. From the laboratory to the clinic
Bailey, I. L., & Lovie-Kitchin, J. E. (2013) · Vision Research · doi:10.1016/j.visres.2013.05.004 · Cited by 246
Self-citationFixation stability and reading speed in patients with newly developed macular disease*
Crossland, M. D., Culham, L. E., & Rubin, G. S. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00213.x · Cited by 245
Glaucoma Patients' Assessment of Their Visual Function and Quality of Life
Jampel, H. D., Schwartz, A., Pollack, I., Abrams, D., Weiss, H., & Miller, R. (2002) · Journal of Glaucoma · doi:10.1097/00061198-200204000-00012 · Cited by 233
Scaling of Visual Acuity Measurements
Westheimer, G. (1979) · Archives of Ophthalmology · doi:10.1001/archopht.1979.01020010173020 · Cited by 226
The Course of Visual Recovery after Optic Neuritis
Beck, R. W., Cleary, P. A., & Backlund, J.-Y. C. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31103-1 · Cited by 225
Williams, C., Northstone, K., Harrad, R. A., Sparrow, J. M., & Harvey, I. (2002) · BMJ · doi:10.1136/bmj.324.7353.1549 · Cited by 221
Clinical Experience with the Surgical Removal of Subfoveal Neovascular Membranes
Berger, A. S., & Kaplan, H. J. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31869-x · Cited by 212
Visual acuity and its measurement
KNIESTEDT, C., & STAMPER, R. (2003) · Ophthalmology Clinics of North America · doi:10.1016/s0896-1549(03)00013-0 · Cited by 204
Home hazards and falls in the elderly: the role of health and functional status.
Northridge, M. E., Nevitt, M. C., Kelsey, J. L., & Link, B. (1995) · American Journal of Public Health · doi:10.2105/ajph.85.4.509 · Cited by 202
Amblyopia Preferred Practice Pattern®
Wallace, D. K., Repka, M. X., Lee, K. A., Melia, M., Christiansen, S. P., Morse, C. L., & Sprunger, D. T. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.10.008 · Cited by 198
Between-Eye Asymmetry in Keratoconus
Zadnik, K., Steger-May, K., Fink, B. A., Joslin, C. E., Nichols, J. J., Rosenstiel, C. E., Tyler, J. A., Yu, J. A., Raasch, T. W., & Schechtman, K. B. (2002) · Cornea · doi:10.1097/00003226-200210000-00008 · Cited by 193
Visual resolution and contour interaction in the fovea and periphery
Jacobs, R. J. (1979) · Vision Research · doi:10.1016/0042-6989(79)90183-4 · Cited by 193
Contrast letter acuity as a visual component for the Multiple Sclerosis Functional Composite
Balcer, L. J., Baier, M. L., Cohen, J. A., Kooijmans, M. F., Sandrock, A. W., Nano–Schiavi, M. L., Pfohl, D. C., Mills, M., Bowen, J., Ford, C., et al. (2003) · Neurology · doi:10.1212/01.wnl.0000094315.19931.90 · Cited by 193
Multitasking: Association Between Poorer Performance and a History of Recurrent Falls
Faulkner, K. A., Redfern, M. S., Cauley, J. A., Landsittel, D. P., Studenski, S. A., Rosano, C., Simonsick, E. M., Harris, T. B., Shorr, R. I., Ayonayon, H. N., et al. (2007) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2007.01147.x · Cited by 191
Higher risk of multiple falls among elderly women who lose visual acuity
Coleman, A. L., Stone, K., Ewing, S. K., Nevitt, M., Cummings, S., Cauley, J. A., Ensrud, K. E., Harris, E. L., Hochberg, M. C., & Mangione, C. M. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2003.09.033 · Cited by 184
Anstey, K. J., Horswill, M. S., Wood, J. M., & Hatherly, C. (2012) · Accident Analysis & Prevention · doi:10.1016/j.aap.2011.10.006 · Cited by 182
Sultan, M. B., Zhou, D., Loftus, J., Dombi, T., & Ice, K. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.02.045 · Cited by 172
Balcer, L. J., Raynowska, J., Nolan, R., Galetta, S. L., Kapoor, R., Benedict, R., Phillips, G., LaRocca, N., Hudson, L., Rudick, R., et al. (2017) · Multiple Sclerosis Journal · doi:10.1177/1352458517690822 · Cited by 168
Balcer, L. J., Baier, M. L., Pelak, V. S., Fox, R. J., Shuwairi, S., Galetta, S. L., Cutter, G. R., & Maguire, M. G. (2000) · Multiple Sclerosis Journal · doi:10.1177/135245850000600305 · Cited by 163
Improving Reading Speed for People with Central Vision Loss through Perceptual Learning
Chung, S. T. L. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6034 · Cited by 159
The European Male Ageing Study (EMAS): design, methods and recruitment
Lee, D. M., O’Neill, T. W., Pye, S. R., Silman, A. J., Finn, J. D., Pendleton, N., Tajar, A., Bartfai, G., Casanueva, F., Forti, G., et al. (2009) · International Journal of Andrology · doi:10.1111/j.1365-2605.2008.00879.x · Cited by 159
Women Who Maintain Optimal Cognitive Function into Old Age
Barnes, D. E., Cauley, J. A., Lui, L., Fink, H. A., McCulloch, C., Stone, K. L., & Yaffe, K. (2007) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2007.01040.x · Cited by 145
‘Visual’ Acuity of the Congenitally Blind Using Visual-to-Auditory Sensory Substitution
Striem-Amit, E., Guendelman, M., & Amedi, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033136 · Cited by 117
Correlates of Attributing New Disability to Old Age
Sarkisian, C. A., Liu, H., Ensrud, K. E., Stone, K. L., Mangione, C. M., of, F. T. S., & Group, O. F. R. (2001) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2001.49033.x · Cited by 69
Cummings, S. R., Lui, L., Glynn, N. W., Mau, T., Cawthon, P. M., Kritchevsky, S. B., Coen, P. M., Goodpaster, B., Marcinek, D. J., Hepple, R. T., et al. (2024) · Journal of the American Geriatrics Society · doi:10.1111/jgs.18763 · Cited by 12
Automated determination of distance visual acuity: towards teleophthalmology services
Kumar, S., Bulsara, M., & Yogesan, K. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00267.x · Cited by 10
Metadata
- Authors
- Bailey, I. L., & Lovie, J. E.
- Venue
- American journal of optometry and physiological optic
- Published
- 1976-11-01
- Volume
- 53
- Issue
- 11
- Pages
- 740-745
- ISSN
- 0093-7002 (ISSN-L)
- OpenAlex
- W1490819121
- Cited by
- 1,407
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.