Nanopatterning effects on astrocyte reactivity
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
An array of design strategies have been targeted toward minimizing failure of implanted microelectrodes by minimizing the chronic glial scar around the microelectrode under chronic conditions. Current approaches toward inhibiting the initiation of glial scarring range from altering the geometry, roughness, size, shape, and materials of the device. Studies have shown materials which mimic the nanotopography of the natural environment in vivo will consequently result in an improved biocompatible response. Nanofabrication of electrode arrays is being pursued in the field of neuronal electrophysiology to increase sampling capabilities. Literature shows a gap in research of nanotopography influence in the reduction of astrogliosis. The aim of this study was to determine optimal feature sizes for neural electrode fabrication, which was defined as eliciting a nonreactive astrocytic response. Nanopatterned surfaces were fabricated with nanoimprint lithography on poly(methyl methacrylate) surfaces. The rate of protein adsorption, quantity of protein adsorption, cell alignment, morphology, adhesion, proliferation, viability, and gene expression was compared between nanopatterned surfaces of different dimensions and non‐nanopatterned control surfaces. Results of this study revealed that 3600 nanopatterned surfaces elicited less of a response when compared with the other patterned and non‐nanopatterned surfaces. The surface instigated cell alignment along the nanopattern, less protein adsorption, less cell adhesion, proliferation and viability, inhibition of glial fibrillary acidic protein, and mitogen‐activated protein kinase kinase 1 compared with all other substrates tested. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 4×
“Hence, the goal of neural electrode fabrication is to optimize the biomaterial surface to promote neuronal proximity to the recording surface, minimize astrogliosis, and eliminate chronic microglial activation.(2) This evidence lends support for our proposed work which examines that the effect-specific nanopatterning…”
BackgroundInfluentialYim, E. K. F., Pang, S. W., & Leong, K. W. (2007) · Experimental Cell Research · doi:10.1016/j.yexcr.2007.02.031 · Cited by 735
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Extracellular matrix of the central nervous system: from neglect to challenge
Zimmermann, D. R., & Dours-Zimmermann, M. T. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0485-9 · Cited by 465 · cited 1×
“Studies have shown that in a healthy adult brain, commonly found ECM proteins, such as fibronectin and collagen, are scarce beneath the blood–brain barrier and choroid plexus.(31,32) When brain tissue damage occurs, such as during neural electrode implantation, the levels of fibronectin is found to be increased, most…”
BackgroundPro‐regenerative properties of cytokine‐activated astrocytes
Liberto, C. M., Albrecht, P. J., Herx, L. M., Yong, V. W., & Levison, S. W. (2004) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2004.02420.x · Cited by 464
Cogan, S. F., Troyk, P. R., Ehrlich, J., Plante, T. D., & Detlefsen, D. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862572 · Cited by 138 · cited 1×
“NIL is inexpensive, fast, and easily produces patterns <10 nm.(28) The rate of protein adsorption, quantity of protein adsorption, cell alignment, morphology, adhesion, proliferation, viability, and gene expression were compared between nanopatterned surfaces of different dimensions and non-nanopatterned control surfa…”
Mechanical force modulates global gene expression and β-catenin signaling in colon cancer cells
Avvisato, C. L., Yang, X., Shah, S., Hoxter, B., Li, W., Gaynor, R., Pestell, R., Tozeren, A., & Byers, S. W. (2007) · Journal of Cell Science · doi:10.1242/jcs.03476 · Cited by 118
Cited by
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“More recently, and perhaps inspired by Takeuchi’s dissolvable system, several groups have investigated the use of biodegradable polymers as shuttles for compliant devices [243, 251, 252].”
BackgroundGulino, M., Kim, D., Pané, S., Santos, S. D., & Pêgo, A. P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00689 · Cited by 159
Peripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67
Biomaterial Approaches to Modulate Reactive Astroglial Response
Zuidema, J. M., Gilbert, R. J., & Gottipati, M. K. (2018) · Cells Tissues Organs · doi:10.1159/000494667 · Cited by 46
“…grids Human NT2 derived Growth in grid patterns Jordan et al., 2016 PMMA microgrooves C6 rat astrocytoma Inhibition of GFAP expression Ereifej et al., 2013 PDMS 1,000-nm grooves Rat cortical Enhanced mitochondrial activity, ATP release, calcium peaks and release Singh et al.,…”
BackgroundEreifej, E. S., Cheng, M. M.-C., Mao, G., & VandeVord, P. J. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.04.023 · Cited by 19
Self-citation
Metadata
- Authors
- Ereifej, E. S., Matthew, H. W., Newaz, G., Mukhopadhyay, A., Auner, G., Salakhutdinov, I., & VandeVord, P. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2012-11-27
- Volume
- 101A
- Issue
- 6
- Pages
- 1743-1757
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2081225544
- Cited by
- 45
- References
- 9
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.