CoChat

Design and demonstration of an intracortical probe technology with tunable modulus

Open access
Simon, Dustin M., Charkhkar, Hamid, St. John, Conan, Rajendran, Sakthi, Kang, Tong, Reit, Radu, Arreaga‐Salas, David, McHail, Daniel G., Knaack, Gretchen L., Sloan, Andrew, Grasse, Dane, Dumas, Theodore C., Rennaker, Robert L., Pancrazio, Joseph J., Voit, Walter E. · 2017 · Journal of Biomedical Materials Research Part A
Cited by 57

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Intracortical probe technology, consisting of arrays of microelectrodes, offers a means of recording the bioelectrical activity from neural tissue. A major limitation of existing intracortical probe technology pertains to limited lifetime of 6 months to a year of recording after implantation. A major contributor to device failure is widely believed to be the interfacial mechanical mismatch of conventional stiff intracortical devices and the surrounding brain tissue. We describe the design, development, and demonstration of a novel functional intracortical probe technology that has a tunable Young's modulus from ∼2 GPa to ∼50 MPa. This technology leverages advances in dynamically softening materials, specifically thiol‐ene/acrylate thermoset polymers, which exhibit minimal swelling of < 3% weight upon softening in vitro. We demonstrate that a shape memory polymer‐based multichannel intracortical probe can be fabricated, that the mechanical properties are stable for at least 2 months and that the device is capable of single unit recordings for durations up to 77 days in vivo. This novel technology, which is amenable to processes suitable for manufacturing via standard semiconductor fabrication techniques, offers the capability of softening in vivo to reduce the tissue‐device modulus mismatch to ultimately improve long term viability of neural recordings. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 159–168, 2017.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.35896

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Simon, D. M., Charkhkar, H., St. John, C., Rajendran, S., Kang, T., Reit, R., Arreaga‐Salas, D., McHail, D. G., Knaack, G. L., Sloan, A., Grasse, D., Dumas, T. C., Rennaker, R. L., Pancrazio, J. J., & Voit, W. E.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2016-09-21
Volume
105
Issue
1
Pages
159-168
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2520052174
Cited by
57
References
12
FWCI
4.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.