The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Dixon techniques for water and fat imaging
Open accessAbstract
In 1984, Dixon published a first paper on a simple spectroscopic imaging technique for water and fat separation. The technique acquires two separate images with a modified spin echo pulse sequence. One is a conventional spin echo image with water and fat signals in‐phase and the other is acquired with the readout gradient slightly shifted so that the water and fat signals are 180° out‐of‐phase. Dixon showed that from these two images, a water‐only image and a fat‐only image can be generated. The water‐only image by the Dixon's technique can serve the purpose of fat suppression, an important and widely used imaging option for clinical MRI. Additionally, the availability of both the water‐only and fat‐only images allows direct image‐based water and fat quantitation. These applications, as well as the potential that the technique can be made highly insensitive to magnetic field inhomogeneity, have generated substantial research interests and efforts from many investigators. As a result, significant improvement to the original technique has been made in the last 2 decades. The following article reviews the underlying physical principles and describes some major technical aspects in the development of these Dixon techniques. J. Magn. Reson. Imaging 2008;28:543–558. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Satellite radar interferometry: Two‐dimensional phase unwrapping
Goldstein, R. M., Zebker, H. A., & Werner, C. L. (1988) · Radio Science · doi:10.1029/rs023i004p00713 · Cited by 2,413
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
NMR chemical shift imaging in three dimensions.
Brown, T. R., Kincaid, B. M., & Ugurbil, K. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.11.3523 · Cited by 1,039
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
MR imaging: clinical use of the inversion recovery sequence.
Bydder, G. M., & YOUNG, I. R. (1985) · PubMed · Cited by 477
Cited by
Breast Tissue Composition and Susceptibility to Breast Cancer
Boyd, N. F., Martin, L. J., Bronskill, M., Yaffe, M. J., Duric, N., & Minkin, S. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djq239 · Cited by 478
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Hernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Imaging-based Quantification of Hepatic Fat: Methods and Clinical Applications
Ma, X., Holalkere, N.-S., R, A. K., Mino-Kenudson, M., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.295085186 · Cited by 312
Wong, V. W.-S., Wong, G. L.-H., Yeung, D. K.-W., Abrigo, J. M., Kong, A. P.-S., Chan, R. S.-M., Chim, A. M.-L., Shen, J., Ho, C.-S., Woo, J., et al. (2014) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.1 · Cited by 275
Crawford, R. J., Filli, L., Elliott, J. M., Nanz, D., Fischer, M. A., Marcon, M., & Ulbrich, E. J. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4596 · Cited by 257
Müller, M. J., Enderle, J., Pourhassan, M., Braun, W., Eggeling, B., Lagerpusch, M., Glüer, C.-C., Kehayias, J. J., Kiosz, D., & Bosy-Westphal, A. (2015) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.109173 · Cited by 254
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M. (2014) · European Radiology · doi:10.1007/s00330-014-3121-1 · Cited by 112
“However, comparable to another study using fat/liver phantoms there was an overestimation of very small fat contents (0-4 %), which might be caused by the magnitude calculation of water-/fat-only images (noise bias) [3] affecting fat estimates according to the previously described algorithm (Eq.”
BackgroundMethodResultInfluentialMRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
Lagerpusch, M., Bosy-Westphal, A., Kehden, B., Peters, A., & Müller, M. J. (2012) · International Journal of Obesity · doi:10.1038/ijo.2011.211 · Cited by 45
Metadata
- Authors
- Ma, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-09
- Volume
- 28
- Issue
- 3
- Pages
- 543-558
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2029425568
- Cited by
- 610
- References
- 23
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.