The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Open accessAbstract
Diffusion‐perfusion mismatch can be used to identify acute stroke patients that could benefit from reperfusion therapies. Early assessment of the mismatch facilitates necessary diagnosis and treatment decisions in acute stroke. We developed the RA pid processing of P erfus I on and D iffusion (RAPID) for unsupervised, fully automated processing of perfusion and diffusion data for the purpose of expedited routine clinical assessment. The RAPID system computes quantitative perfusion maps (cerebral blood volume, CBV; cerebral blood flow, CBF; mean transit time, MTT; and the time until the residue function reaches its peak, Tmax) using deconvolution of tissue and arterial signals. Diffusion‐weighted imaging/perfusion‐weighted imaging (DWI/PWI) mismatch is automatically determined using infarct core segmentation of ADC maps and perfusion deficits segmented from Tmax maps. The performance of RAPID was evaluated on 63 acute stroke cases, in which diffusion and perfusion lesion volumes were outlined by both a human reader and the RAPID system. The correlation of outlined lesion volumes obtained from both methods was r2 = 0.99 for DWI and r2 = 0.96 for PWI. For mismatch identification, RAPID showed 100% sensitivity and 91% specificity. The mismatch information is made available on the hospital's PACS within 5–7 min. Results indicate that the automated system is sufficiently accurate and fast enough to be used for routine care as well as in clinical trials. J. Magn. Reson. Imaging 2010;32:1024–1037. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
Hansen, P. C. (1998) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719697 · Cited by 2,909
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
Albers, G. W., Thijs, V. N., Wechsler, L., Kemp, S., Schlaug, G., Skalabrin, E., Bammer, R., Kakuda, W., Lansberg, M. G., Shuaib, A., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20976 · Cited by 1,268
Self-citationTHE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Davis, S. M., Donnan, G. A., Parsons, M. W., Levi, C., Butcher, K. S., Peeters, A., Barber, P. A., Bladin, C., De Silva, D. A., Byrnes, G., et al. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70044-9 · Cited by 1,052
Wintermark, M., Flanders, A. E., Velthuis, B., Meuli, R., van Leeuwen, M., Goldsher, D., Pineda, C., Serena, J., Schaaf, I. V. D., Waaijer, A., et al. (2006) · Stroke · doi:10.1161/01.str.0000209238.61459.39 · Cited by 777
Boxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Theoretical Basis of Indicator-Dilution Methods For Measuring Flow and Volume
Zierler, K. L. (1962) · Circulation Research · doi:10.1161/01.res.10.3.393 · Cited by 510
Kidwell, C. S., Alger, J. R., & Saver, J. L. (2003) · Stroke · doi:10.1161/01.str.0000097608.38779.cc · Cited by 473
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute Stroke
Olivot, J.-M., Mlynash, M., Thijs, V. N., Kemp, S., Lansberg, M. G., Wechsler, L., Bammer, R., Marks, M. P., & Albers, G. W. (2009) · Stroke · doi:10.1161/strokeaha.108.526954 · Cited by 401
Self-citationWintermark, M., Reichhart, M., Cuisenaire, O., Maeder, P., Thiran, J.-P., Schnyder, P., Bogousslavsky, J., & Meuli, R. (2002) · Stroke · doi:10.1161/01.str.0000023579.61630.ac · Cited by 345
Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Automatic selection of arterial input function using cluster analysis
Mouridsen, K., Christensen, S., Gyldensted, L., & Østergaard, L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20759 · Cited by 214
Late secondary ischemic injury in patients receiving intraarterial thrombolysis
Kidwell, C. S., Saver, J. L., Starkman, S., Duckwiler, G., Jahan, R., Vespa, P., Villablanca, J. P., Liebeskind, D. S., Gobin, Y. P., Vinuela, F., et al. (2002) · Annals of Neurology · doi:10.1002/ana.10380 · Cited by 202
Shih, L. C., Saver, J. L., Alger, J. R., Starkman, S., Leary, M. C., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Villablanca, J. P., et al. (2003) · Stroke · doi:10.1161/01.str.0000072998.70087.e9 · Cited by 195
On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1307 · Cited by 182
Diffusion-perfusion MR evaluation of perihematomal injury in hyperacute intracerebral hemorrhage
Kidwell, C. S., Saver, J. L., Mattiello, J., Warach, S., Liebeskind, D. S., Starkman, S., Vespa, P. M., Villablanca, J. P., Martin, N. A., Frazee, J., et al. (2001) · Neurology · doi:10.1212/wnl.57.9.1611 · Cited by 158
Calamante, F., Gadian, D. G., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10643 · Cited by 147
Christensen, S., Mouridsen, K., Wu, O., Hjort, N., Karstoft, H., Thomalla, G., Röther, J., Fiehler, J., Kucinski, T., & Østergaard, L. (2009) · Stroke · doi:10.1161/strokeaha.108.546069 · Cited by 141
Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation
Kjølby, B. F., Østergaard, L., & Kiselev, V. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20920 · Cited by 130
Bammer, R., Stollberger, R., Augustin, M., Simbrunner, J., Offenbacher, H., Kooijman, H., Ropele, S., Kapeller, P., Wach, P., Ebner, F., et al. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn15799 · Cited by 104
Self-citationPerfusion mapping with multiecho multishot parallel imaging EPI
Newbould, R. D., Skare, S. T., Jochimsen, T. H., Alley, M. T., Moseley, M. E., Albers, G. W., & Bammer, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21255 · Cited by 70
Self-citationDiffusion-Weighted Imaging in Acute Stroke
Schaefer, P. W., Copen, W. A., Lev, M. H., & González, R. (2005) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.08.011 · Cited by 61
MRI based diffusion and perfusion predictive model to estimate stroke evolution
Rose, S., Chalk, J. B., Griffin, M., Janke, A. L., Chen, F., McLachan, G. J., Peel, D. A., Zelaya, F. O., Markus, H. S., Jones, D. K., et al. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00435-0 · Cited by 51
Kosior, J. C., & Frayne, R. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20843 · Cited by 23
Cited by
Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection
Campbell, B. C. V., Mitchell, P. J., Kleinig, T. J., Dewey, H. M., Churilov, L., Yassi, N., Yan, B., Dowling, R. J., Parsons, M. W., Oxley, T. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414792 · Cited by 5,819
Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in Stroke
Saver, J. L., Goyal, M., Bonafe, A., Diener, H.-C., Levy, E. I., Pereira, V. M., Albers, G. W., Cognard, C., Cohen, D. J., Hacke, W., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415061 · Cited by 5,193
Self-citationThrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging
Albers, G. W., Marks, M. P., Kemp, S., Christensen, S., Tsai, J. P., Ortega-Gutierrez, S., McTaggart, R. A., Torbey, M. T., Kim-Tenser, M., Leslie-Mazwi, T., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1713973 · Cited by 4,930
Self-citationPowers, W. J., Derdeyn, C. P., Biller, J., Coffey, C. S., Hoh, B. L., Jauch, E. C., Johnston, K. C., Johnston, S. C., Khalessi, A. A., Kidwell, C. S., et al. (2015) · Stroke · doi:10.1161/str.0000000000000074 · Cited by 2,124
Lansberg, M. G., Straka, M., Kemp, S., Mlynash, M., Wechsler, L. R., Jovin, T. G., Wilder, M. J., Lutsep, H. L., Czartoski, T. J., Bernstein, R. A., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70203-x · Cited by 784
Self-citation
Metadata
- Authors
- Straka, M., Albers, G. W., & Bammer, R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-10-28
- Volume
- 32
- Issue
- 5
- Pages
- 1024-1037
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2086121111
- Cited by
- 401
- References
- 30
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.