Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Purpose: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. Materials and Methods: We acquired high in‐plane resolution (1.2 × 1.2 mm 2) diffusion‐weighted images with 16 different values of b ranging from 0 to 900 s/mm 2, in three orthogonal directions, on 3T systems with a 32‐multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. Results: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. Conclusion: Our initial report suggests that high‐resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624–632. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286 · cited 2×
“Intravoxel incoherent motion (IVIM) imaging is a method proposed by Le Bihan et al (9) to separate the signal arising from a diffusion sequence such as the Stejskal-Tanner sequence (10) into a vascular and a nonvascular component.”
MethodLe Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 3×
“The expected behavior of signal amplitude as a function of b-value in this model has been shown to be biexponential (9).”
BackgroundMethodJain, R. K., di Tomaso, E., Duda, D. G., Loeffler, J. S., Sorensen, A. G., & Batchelor, T. T. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2175 · Cited by 1,405
Albers, G. W., Thijs, V. N., Wechsler, L., Kemp, S., Schlaug, G., Skalabrin, E., Bammer, R., Kakuda, W., Lansberg, M. G., Shuaib, A., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20976 · Cited by 1,268 · cited 1×
“In the evaluation of acute ischemic stroke, the mismatch between the area of abnormal perfusion and diffusion is considered to be salvageable tissue (1) and has been proposed to select patients for thrombolytic treatment (2–4) and as a predicator of recovery with reperfusion (5,6).”
BackgroundPerfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151 · cited 1×
“MTT is overestimated in cases of contrast leakage (33,34).”
BackgroundSeber, G. A. F., & Lee, A. J. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/9780471722199 · Cited by 1,135
Law, M., Yang, S., Wang, H., Babb, J. S., Johnson, G., Cha, S., Knopp, E. A., & Zagzag, D. (2003) · PubMed Central · Cited by 1,084
Davis, S. M., Donnan, G. A., Parsons, M. W., Levi, C., Butcher, K. S., Peeters, A., Barber, P. A., Bladin, C., De Silva, D. A., Byrnes, G., et al. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70044-9 · Cited by 1,052 · cited 1×
“In the evaluation of acute ischemic stroke, the mismatch between the area of abnormal perfusion and diffusion is considered to be salvageable tissue (1) and has been proposed to select patients for thrombolytic treatment (2–4) and as a predicator of recovery with reperfusion (5,6).”
BackgroundHacke, W., Albers, G., Al-Rawi, Y., Bogousslavsky, J., Davalos, A., Eliasziw, M., Fischer, M., Furlan, A., Kaste, M., Lees, K. R., et al. (2005) · Stroke · doi:10.1161/01.str.0000149938.08731.2c · Cited by 1,015
Baish, J. W., & Jain, R. K. (2000) · PubMed · Cited by 714
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundEcho-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Hacke, W., Furlan, A. J., Al-Rawi, Y., Davalos, A., Fiebach, J. B., Gruber, F., Kaste, M., Lipka, L. J., Pedraza, S., Ringleb, P. A., et al. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70267-9 · Cited by 574
Furlan, A. J., Eyding, D., Albers, G. W., Al-Rawi, Y., Lees, K. R., Rowley, H. A., Sachara, C., Soehngen, M., Warach, S., & Hacke, W. (2006) · Stroke · doi:10.1161/01.str.0000217403.66996.6d · Cited by 540
Law, M., Young, R. J., Babb, J. S., Peccerelli, N., Chheang, S., Gruber, M. L., Miller, D. C., Golfinos, J. G., Zagzag, D., & Johnson, G. (2008) · Radiology · doi:10.1148/radiol.2472070898 · Cited by 534
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423 · cited 3×
“The relation between the IVIM perfusion parameters and the standard perfusion parameters has been studied theoretically (11), but an experimental verification is still lacking.”
BackgroundInfluentialFisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356 · cited 1×
“It is therefore believed that the major source of contrast agent change is extravascular (45,46).”
BackgroundNon-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Paulson, E. S., & Schmainda, K. M. (2008) · Radiology · doi:10.1148/radiol.2492071659 · Cited by 327 · cited 1×
“MTT is overestimated in cases of contrast leakage (33,34).”
BackgroundCerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T.
Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J. (1990) · Radiology · doi:10.1148/radiology.176.1.2353094 · Cited by 304
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
Lemke, A., Stieltjes, B., Schad, L. R., & Laun, F. B. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.03.004 · Cited by 286 · cited 1×
“The optimal fitting algorithm and the optimal distribution of b values (50), as well as the accuracy and robustness of the measurements (51), have been insufficiently investigated.”
BackgroundCalamante, F., Gadian, D. G., & Connelly, A. (2002) · Stroke · doi:10.1161/01.str.0000014208.05597.33 · Cited by 283
Danchaivijitr, N., Waldman, A. D., Tozer, D. J., Benton, C. E., Brasil Caseiras, G., Tofts, P. S., Rees, J. H., & Jäger, H. R. (2008) · Radiology · doi:10.1148/radiol.2471062089 · Cited by 238
Lemke, A., Laun, F. B., Klau, M., Re, T. J., Simon, D., Delorme, S., Schad, L. R., & Stieltjes, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b62271 · Cited by 231 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundBihan, D. L., Turner, R., & Macfall, J. R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100305 · Cited by 228 · cited 1×
“This assumes that D* is significantly greater than D, so that the influence of pseudo-diffusion on signal decay can be neglected for b values greater than 200 s/mm(2) (32).”
BackgroundSigmund, E. E., Cho, G. Y., Kim, S., Finn, M., Moccaldi, M., Jensen, J. H., Sodickson, D. K., Goldberg, J. D., Formenti, S., & Moy, L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22740 · Cited by 224 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundDiffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211 · cited 1×
“Which of these highly simplified models is more appropriate depends on vascular geometry, the velocity of blood water molecules, and their relationships to the parameters of the diffusion sequence (15).”
BackgroundQuantitative Measurement of Brain Perfusion with Intravoxel Incoherent Motion MR Imaging
Federau, C., Maeder, P., O’Brien, K., Browaeys, P., Meuli, R., & Hagmann, P. (2012) · Radiology · doi:10.1148/radiol.12120584 · Cited by 191 · cited 2×
“Finally, and importantly, IVIM perfusion parameters are intrinsically quantitative and are sensitive to hypercapnia induced vasodilatation and hyperoxia induced vasoconstriction (30).”
BackgroundSelf-citationSumi, M., Van Cauteren, M., Sumi, T., Obara, M., Ichikawa, Y., & Nakamura, T. (2012) · Radiology · doi:10.1148/radiol.12111248 · Cited by 177 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundHuman cerebral circulation: positron emission tomography studies
Ito, H., Kanno, I., & Fukuda, H. (2005) · Annals of Nuclear Medicine · doi:10.1007/bf03027383 · Cited by 170 · cited 1×
“In comparison to DSC, IVIM might have a potentially higher resolution, because the bolus injection of gadolinium used in DSC can result in over 50% signal change in the brain (34,41–43), much larger than the 4% blood volume of the brain (44).”
BackgroundGuiu, B., Petit, J.-M., Capitan, V., Aho, S., Masson, D., Lefevre, P.-H., Favelier, S., Loffroy, R., Vergès, B., Hillon, P., et al. (2012) · Radiology · doi:10.1148/radiol.12112478 · Cited by 169 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundRiches, S. F., Hawtin, K. E., Charles-Edwards, E., & de Souza, N. M. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1328 · Cited by 128 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundA quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain
Henkelman, R. M., Neil, J. J., & Xiang, Q. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320407 · Cited by 104 · cited 1×
“of a diffusion sequence including an isotropic coherent flow model (12) and an isotropic coherent flow model including the fractal properties of the vascular network (13), both with signal amplitude decay dependent on a cardinal sine function.”
BackgroundMeasuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study
Bihan, D. L., Moonen, C. T. W., van Zijl, P. C. M., Pekar, J., & DesPres, D. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199101000-00002 · Cited by 102
Sumi, M., & Nakamura, T. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3227 · Cited by 83 · cited 1×
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundA general model of microcirculatory blood flow effects in gradient sensitized MRI
Kennan, R. P., Gao, J., Zhong, J., & Gore, J. C. (1994) · Medical Physics · doi:10.1118/1.597170 · Cited by 65 · cited 1×
“An intermediate model between those models has been proposed as well (14).”
BackgroundNeil, J. J., Bosch, C. S., & Ackerman, J. J. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320109 · Cited by 57
Quantitative measurement of tissue perfusion and diffusion in vivo
Chenevert, T. L., Pipe, J. G., Williams, D. M., & Brunberg, J. A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170123 · Cited by 54
Perfusion and diffusion MR imaging
King, M. D., van Bruggen, N., Busza, A. L., Houseman, J., Williams, S., & Gadian, D. G. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240210 · Cited by 50 · cited 1×
“The optimal fitting algorithm and the optimal distribution of b values (50), as well as the accuracy and robustness of the measurements (51), have been insufficiently investigated.”
BackgroundVASCULAR STRUCTURE OF GLIOBLASTOMAS
Scatliff, J. H., Radcliffe, W. B., PITTMAN, H. H., & PARK, C. H. (1969) · American Journal of Roentgenology · doi:10.2214/ajr.105.4.795 · Cited by 49
Regional differences in rat brain displayed by fast MRI with superparamagnetic contrast agents
Majumdar, S., Zoghbi, S. S., & Gore, J. C. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90082-3 · Cited by 49 · cited 1×
“It is therefore believed that the major source of contrast agent change is extravascular (45,46).”
BackgroundMeasurement of tissue blood flow using intravascular relaxation agents and resonance imaging
Gore, J. C., & Majumdar, S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140210 · Cited by 41
The perfusion fraction in volunteers and in patients with ischaemic stroke
Wirestam, R., Brockstedt, S., Lindgren, A., Geijer, B., Thomsen, C., Holtås, S., & Ståhlberg, F. (1997) · Acta Radiologica · doi:10.1080/02841859709172110 · Cited by 37
Metadata
- Authors
- Federau, C., O'Brien, K., Meuli, R., Hagmann, P., & Maeder, P.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2013-09-23
- Volume
- 39
- Issue
- 3
- Pages
- 624-632
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2126940228
- Cited by
- 204
- References
- 45
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.