The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Abstract
The extended phase graph (EPG) concept represents a powerful tool for depicting and understanding the magnetization response of a broad variety of MR sequences. EPGs focus on echo generation as well as on classification and use a Fourier based magnetization description in terms of “configurations states”. The effect of gradients, radiofrequency (RF) pulses, relaxation, and motion phenomena during the MR sequence is characterized as the action of a few matrix operations on these configuration states. Thus, the EPG method allows for fast and precise quantitation of echo intensities even if several gradients and RF pulses are applied. EPG diagrams aid in the comprehension of different types of echoes and their corresponding echo time. Despite its several benefits in regard to a large number of problems and issues, researchers and users still often refrain from applying EPGs. It seems that “phase graphing” is still seen as a kind of “magic.” The present review investigates the foundation of EPGs and sheds light on prerequisites for adding more advanced phenomena such as diffusion. The links between diagrams and calculations are discussed. A further focus is on limitations and simplifications as well recent extensions within the EPG concept. To make the review complete, representative software for EPG coding is provided. J. Magn. Reson. Imaging 2015;41:266–295.© 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Tumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
Solvent suppression in fourier transform nuclear magnetic resonance
Hore, P. J. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90240-8 · Cited by 770
Mansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
Use of Rotating Coordinates in Magnetic Resonance Problems
Rabi, I. I., Ramsey, N. F., & Schwinger, J. (1954) · Reviews of Modern Physics · doi:10.1103/revmodphys.26.167 · Cited by 439
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Twieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335
Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Spoiling of transverse magnetization in steady‐state sequences
Zur, Y., Wood, M. L., & Neuringer, L. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210210 · Cited by 306
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing
Zur, Y., Stokar, S., & Bendel, P. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060206 · Cited by 253
Hennig, J. (1991) · Concepts in Magnetic Resonance · doi:10.1002/cmr.1820030302 · Cited by 241
Effects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments
Woessner, D. E. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731821 · Cited by 220
Selective excitation in Fourier transform nuclear magnetic resonance
Morris, G. A., & Freeman, R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.031 · Cited by 204
Hennig, J., & Scheffler, K. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1153 · Cited by 195
Diffusion and field-gradient effects in NMR Fourier spectroscopy
Kaiser, R. I., Bartholdi, E., & Ernst, R. R. (1974) · The Journal of Chemical Physics · doi:10.1063/1.1681477 · Cited by 183
Hargreaves, B. A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23742 · Cited by 126
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10658 · Cited by 123
Self-citationMarkl, M., & Leupold, J. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23638 · Cited by 107
Hennig, J., & Hodapp, M. T. (1993) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02660372 · Cited by 93
Weigel, M., & Hennig, J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20816 · Cited by 88
Self-citationExtended phase graphs with anisotropic diffusion
Weigel, M., Schwenk, S., Kiselev, V. G., Scheffler, K., & Hennig, J. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.05.011 · Cited by 67
Self-citationSteady‐state diffusion‐weighted imaging: theory, acquisition and analysis
McNab, J. A., & Miller, K. L. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1509 · Cited by 62
Malik, S., Padormo, F., Price, A. N., & Hajnal, J. V. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24153 · Cited by 34
Larson, P. E. Z., Kerr, A. B., Reed, G. D., Hurd, R. E., Kurhanewicz, J. V., Pauly, J. M., & Vigneron, D. B. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2168235 · Cited by 23
Fast diffusion‐weighted steady state free precession imaging of in vivo knee cartilage
Bieri, O., Ganter, C., Welsch, G. H., Trattnig, S., Mamisch, T. C., & Scheffler, K. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23061 · Cited by 23
Cited by
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
MR fingerprinting Deep RecOnstruction NEtwork (DRONE)
Cohen, O., Zhu, B., & Rosen, M. S. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27198 · Cited by 306
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Effects of formalin fixation and temperature on MR relaxation times in the human brain
Birkl, C., Langkammer, C., Golob‐Schwarzl, N., Leoni, M., Haybaeck, J., Goessler, W., Fazekas, F., & Ropele, S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3477 · Cited by 111
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Weigel, M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-04-16
- Volume
- 41
- Issue
- 2
- Pages
- 266-295
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1963427860
- Cited by
- 426
- References
- 36
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.