The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Laser stimulation of the auditory nerve
Abstract
Background and Objectives: For centuries, electric current has been used to stimulate neurons. Shortcomings of electrical stimulation include the contact between the stimulating electrode and the tissue, and the non‐selective stimulation of the tissue. In contrast to electric stimulation, optical radiation can provide spatially selective neural stimulation without tissue contact. Study Design/Materials and Methods: Acute in vivo experiments using gerbils were conducted to record optically evoked compound action potentials (CAPs) from the cochlea. Results: Optical radiation evokes CAPs in normal hearing animals and in deafened animals, in which cochleae lack outer and inner hair cells. Stimulation threshold was measured as 0.018±0.003 J/cm 2 (mean±SE). Laser radiation could be increased by 30–40 dB until drastic changes were seen in cochlear function. Cochlear response amplitudes to optical radiation were stable over extended stimulation times. Conclusions: We have demonstrated that the auditory nerve can be stimulated by optical radiation. One potential clinical use of this technology would be for cochlear implants. Lasers Surg. Med. 38:745–753, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PEST: Efficient Estimates on Probability Functions
Taylor, M. M., & Creelman, C. D. (1967) · The Journal of the Acoustical Society of America · doi:10.1121/1.1910407 · Cited by 1,173
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“electrode tissue interface by high current levels or by chemical reactions [2–7].”
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90221-2 · Cited by 96 · cited 1×
“electrode tissue interface by high current levels or by chemical reactions [2–7].”
Cited by
Biological effects and medical applications of infrared radiation
Tsai, S.-R., & Hamblin, M. R. (2017) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2017.04.014 · Cited by 477
Biophysical Mechanisms of Transient Optical Stimulation of Peripheral Nerve
Wells, J., Kao, C., Konrad, P., Milner, T., Kim, J., Mahadevan-Jansen, A., & Jansen, E. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104786 · Cited by 386
Self-citationNonthermal and reversible control of neuronal signaling and behavior by midinfrared stimulation
Liu, X., Qiao, Z., Chai, Y., Zhu, Z., Wu, K., Ji, W., Li, D., Xiao, Y., Mao, L., Chang, C., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2015685118 · Cited by 288
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“…known as optogenetics), by directly introducing chemicals such as caged neurotransmitters to the cells, or by utilizing the endogenous sensitivity of cells to light (Callaway and Yuste, 2002; Hirase et al., 2002; Boyden et al., 2005; Wells et al., 2005; Izzo et al., 2006; Rajguru et al., 2010a).”
BackgroundMethodOptical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“To date, a number of studies focusing on the safety in both acute and chronic usage of INS in the cochlea have been performed [66, 67, 97, 98, 90].”
BackgroundInfluentialCombined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
“Electrode-based techniques have long been the prominent method for activating, modifying, recording and studying neurons and their behavior [1-3].”
Duke, A. R., Peterson, E., Mackanos, M. A., Atkinson, J., Tyler, D., & Jansen, E. D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066006 · Cited by 45
Self-citationOptical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
Design Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Izzo, A. D., Richter, C., Jansen, E. D., & Walsh, J. T.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 2006-07-26
- Volume
- 38
- Issue
- 8
- Pages
- 745-753
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2135423119
- Cited by
- 228
- References
- 4
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.