The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Open accessAbstract
Liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been recognized as a primary methodology for the accurate analysis of endogenous steroid hormones in biological samples. This review focuses on the use of LC–MS/MS in clinical laboratories to assist with the diagnosis of diverse groups of endocrine and metabolic diseases. Described analytical methods use on‐line and off‐line sample preparation and analytical derivatization to enhance analytical sensitivity, specificity, and clinical utility. Advantages of LC–MS/MS as an analytical technique include high specificity, possibility to simultaneously measure multiple analytes, and the ability to assess the specificity of the analysis in every sample. All described analytical methods were extensively validated, utilized in routine diagnostic practice, and were applied in a number of clinical and epidemiological studies, including a study of the steroidogenesis in ovarian follicles. © 2009 Wiley Periodicals, Inc. Mass Spec Rev 29:480‐502, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2004) · Fertility and Sterility · doi:10.1016/j.fertnstert.2003.10.004 · Cited by 9,050
Franks, S. (1995) · New England Journal of Medicine · doi:10.1056/nejm199509283331307 · Cited by 2,463
Amenorrhea associated with bilateral polycystic ovaries
Stein, I. F., & Leventhal, M. L. (1935) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(15)30642-6 · Cited by 2,121
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176 · cited 2×
“To address the issue of poor performance of commercial IAs for Te, it was suggested to use the isotope-dilution LC–MS/MS method for the routine measurement of Te in samples from women and children (Rosner et al., 2007).”
BackgroundMethodCurrent databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987 · cited 1×
“Thus, targeted values for sensitivity, accuracy, precision, and the analytical measurement range (AMR) should be based on the clinical needs of each individual marker (Ricos et al., 1999; http://www.westgard.com/biodatabase1.htm, 2008).”
BackgroundGlucocorticoids and insulin resistance: old hormones, new targets
ANDREWS, R. C., & WALKER, B. R. (1999) · Clinical Science · doi:10.1042/cs0960513 · Cited by 731
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580 · cited 1×
“The studies (Taieb et al., 2003; Matsumoto & Bremner, 2004; Wang et al., 2004) suggested the need for the development of high-sensitivity/high-specificity methods for the measurement of Te in samples from women and children.”
BackgroundNeuroprotective effects of estrogens: potential mechanisms of action
Green, P. S., & Simpkins, J. W. (2000) · International Journal of Developmental Neuroscience · doi:10.1016/s0736-5748(00)00017-4 · Cited by 523
McNATTY, K. P., SMITH, D. M., MAKRIS, A., OSATHANONDH, R., & RYAN, K. J. (1979) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-49-6-851 · Cited by 522
Cited by
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Kushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.143222 · Cited by 283
Self-citationAdvantages and challenges of mass spectrometry assays for steroid hormones
Stanczyk, F. Z., & Clarke, N. J. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.05.001 · Cited by 265
Eisenhofer, G., Peitzsch, M., Kaden, D., Langton, K., Pamporaki, C., Masjkur, J., Tsatsaronis, G., Mangelis, A., Williams, T. A., Reincke, M., et al. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.05.002 · Cited by 171
A new strategy for ionization enhancement by derivatization for mass spectrometry
Iwasaki, Y., Nakano, Y., Mochizuki, K., Nomoto, M., Takahashi, Y., Ito, R., Saito, K., & Nakazawa, H. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.02.008 · Cited by 113
Antonelli, G., Ceccato, F., Artusi, C., Marinova, M., & Plebani, M. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.10.004 · Cited by 111
Travers, S., Martinerie, L., Bouvattier, C., Boileau, P., Lombès, M., & Pussard, E. (2017) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2016.06.005 · Cited by 81
Marcos, J., Renau, N., Casals, G., Segura, J., Ventura, R., & Pozo, O. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.12.030 · Cited by 76
Shackleton, C., Pozo, O. J., & Marcos, J. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00135 · Cited by 75
The short cosyntropin test revisited: new normal reference range using LC-MS/MS
Ueland, G. Å., Methlie, P., Øksnes, M., Thordarson, H. B., Sagen, J., Kellmann, R., Mellgren, G., Ræder, M., Dahlqvist, P., Dahl, S. R., et al. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-02602 · Cited by 71
Boggs, A. S. P., Bowden, J. A., Galligan, T. M., Guillette, L. J., & Kucklick, J. R. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9512-1 · Cited by 71
Gonzalez, E., van Liempd, S., Conde-Vancells, J., Gutierrez-de Juan, V., Perez-Cormenzana, M., Mayo, R., Berisa, A., Alonso, C., Marquez, C. A., Barr, J., et al. (2012) · Metabolomics · doi:10.1007/s11306-011-0329-9 · Cited by 69
Kalogera, E., Pistos, C., Provatopoulou, X., Athanaselis, S., Spiliopoulou, C., & Gounaris, A. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.09.022 · Cited by 31
Burt, M. G., Mangelsdorf, B. L., Rogers, A., Ho, J. T., Lewis, J. G., Inder, W. J., & Doogue, M. P. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3576 · Cited by 30
Quality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Köhrle, J., & Richards, K. H. (2020) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1175-4610 · Cited by 7
Metadata
- Authors
- Kushnir, M. M., Rockwood, A. L., & Bergquist, J.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-08-25
- Volume
- 29
- Issue
- 3
- Pages
- 480-502
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2021682647
- Cited by
- 159
- References
- 26
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.