Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The purpose of this experiment was to determine the stimulating and recording characters of fascicular physioelectrical signals in the activity of peripheral nerves by longitudinally implanted intrafascicular electrodes (LIFEs) in a rabbit sciatic nerve model, and discuss the future application of LIFEs in functional electrical stimulation (FES) and control of electric arm prosthesis. In methodology, LIFEs were inserted into the fasciculus of the sciatic nerves of rabbits and used as recording electrodes and stimulating electrodes, respectively. Motor‐evoked potentials (MEPs), cortical somatosensory‐evoked potentials (CSEPs), and electromyography (EMG) were recorded by using a transcranial stimulation system (TCS). LIFEs were found to have stable stimulating and recording characters. The interpeak amplitudes (IPAs) of MEPs ranged from 78–156 μV (mean ± SD, 102 ± 23.2 μV). The onset latency (OL) of MEPs ranged from 9.8–11.2 msec (mean ± SD, 10.8 ± 0.6 msec). The interpeak amplitudes (IPAs) of CSEPs ranged from 5.8–7.2 μV (mean ± SD, 6.7 ± 0.5 μV). The onset latency (OL) of CSEPs ranged from 11.4–14.6 msec (mean ± SD, 12.8 ± 1.3 msec). EMGs could be recorded in the gastrocnemius, but could not be recorded in the tibialis anterior muscle. In conclusion, longitudinally implanted intrafascicular electrodes can act as intrafascicular stimulating and recording electrodes with high selective characters. They can provide a new way to study fascicular physioelectrical signals and their function in the activity of peripheral nerves. © 2003 Wiley‐Liss, Inc. MICROSURGERY 23:268–273 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
Metallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
Sweeney, J. D., Crawford, N. R., & Brandon, T. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510525 · Cited by 51
Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Yoshida, K., Jovanović, K., & Stein, R. B. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00176-4 · Cited by 49
Cited by
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36
“This is consistent with animal studies that demonstrated that intrafascicular stimulation is sufficiently localized to stimulate small clusters of nerve fibers within fascicles [17-19].”
Result
Metadata
- Authors
- Zheng, X., Zhang, J., Chen, T., & Chen, Z.
- Venue
- Microsurgery
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 23
- Issue
- 3
- Pages
- 268-273
- ISSN
- 0738-1085 (ISSN-L)
- 1098-2752
- OpenAlex
- W1989492476
- Cited by
- 22
- References
- 7
- FWCI
- 0.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.