Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Abstract
This paper presents a technique for stimulating and recording from multiple intact spinal roots in the in vitro mudpuppy (Necturus maculatus) spinal cord-forearm preparation using fine wire electrodes, a modified intrafascicular electrode. We found that multiple spinal roots of the preparation could be implanted with these modified electrodes for independent stimulation or recording of the roots without inducing mechanical vibrations, disrupting conduction, or obscuring the view of or access to the spinal cord. Recording and stimulation performance using these electrodes was compared with results obtained using conventional hook electrodes. We found that intrafascicular electrodes were more efficient than hook electrodes for stimulating nerve fibers, being able to produce equivalent levels of activation using stimulation levels that were an order of magnitude smaller. Compound action potential signals recorded from electrodes implanted in the spinal roots were found to be larger than those from hook electrodes placed around the corresponding spinal nerve, showing that intrafascicular electrodes are more efficient at recording activity in the nerve. Moreover, it was possible to record evoked activity from cutaneous mechanoreceptors, even though the signal to noise ratio was low. Rough estimates of the conduction velocities for the fastest components in the compound action potentials were calculated and found to be around 17.5 m/s for both dorsal and ventral roots.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Comparatively smaller stimulus intensities can be used with intrafascicular electrodes to achieve equivalent levels to those of extraneural electrodes.
“Comparatively smaller stimulus intensities can be used to achieve equivalent levels to those of extraneural electrodes (Yoshida et al., 2000) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Yoshida et al., 2000
Activity from cutaneous receptors in response to stimuli has been recorded in several studies, but the activity was small and difficult to distinguish from background noise.
“Activity arising from cutaneous receptors in response to stimuli has been recorded in several studies, although activity was found to be small and difficult to distinguish from the background noise in the recording (Malmstrom et al., 1998; Yoshida et al., 2000) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Yoshida et al., 2000
Muscle recruitment curves as function of current amplitude were typical for the stimulation strategies used.
“Muscle recruitment curves as function of current amplitude were typical for the stimulation strategies used (Grill and Mortimer 1996b, Yoshida et al 2000, Navarro et al 2001, 2007, Polasek et al 2007).”
From Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles (2011) · cites this paper as Yoshida et al 2000
To achieve a selective interfacing with several nerve fascicles, a corresponding number of LIFEs needs to be implanted, whereas only one TIME may provide the same results.
“though the LIFE has a high degree of selectivity (Yoshida et al 2000), to achieve a selective interfacing with several nerve fascicles a corresponding number of LIFEs needs to be implanted, whereas only one TIME may provide the same results”
From Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles (2011) · cites this paper as Yoshida et al 2000
The currents applied to TIME, LIFE and cuff devices remained within the range of safety.
“The currents applied to TIME, LIFE and cuff devices remained within the range of safety (Yoshida et al 2000, Navarro et al 2001, Boretius et al 2010).”
From Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles (2011) · cites this paper as Yoshida et al 2000
Longitudinal intra-fascicular electrodes can selectively stimulate nerve fibers, enabling activation of separate axonal subsets within a single fascicle and induction of graded responses.
“They are also able to selectively stimulate nerve fibers, even enabling the activation of separate axonal subsets within a single fascicle [88], and the induction of graded responses [89].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [89]
Cites
Electrical Signs of Nervous Activity
Erlanger, J., & Gasser, H. S. (1937) · University of Pennsylvania Press eBooks · doi:10.9783/9781512815757 · Cited by 517 · see citing works
Electrodes and the measurement of bioelectric events
Shipton, H. W. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90185-5 · Cited by 303 · see citing works
Electrodes and the measurement of bioelectric events
Geddes, L. A. (1972) · Medical Entomology and Zoology · Cited by 276 · see citing works
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · see citing works
Self-citationChronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · see citing works
Yoshida, K., & Horch, K. W. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481986 · Cited by 132 · see citing works
Self-citationAn intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107 · see citing works
Yoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69 · see citing works
Self-citationThe activity of interneurons during locomotion in the in vitro necturus spinal cord
Wheatley, M., Jovanović, K., Stein, R. B., & Lawson, V. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.71.6.2025 · Cited by 57 · see citing works
Self-citationMicroneurography for the recording and selective stimulation of afferents: An assessment
Calancie, B. M., & Stein, R. B. (1988) · Muscle & Nerve · doi:10.1002/mus.880110617 · Cited by 49 · see citing works
Self-citationA comparison of intact and in-vitro locomotion in an adult amphibian
Wheatley, M., Edamura, M., & Stein, R. B. (1992) · Experimental Brain Research · doi:10.1007/bf00228189 · Cited by 47 · see citing works
Self-citationAction potential classification with dual channel intrafascicular electrodes
McNaughton, T. G., & Horch, K. W. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301727 · Cited by 41 · see citing works
Electrical Signs of Nervous Activity
R, &. B. (1937) · The American Journal of the Medical Sciences · doi:10.1097/00000441-193710000-00021 · Cited by 41 · see citing works
Wijesinghe, R. S., Gielen, F. L. H., & Wikswo, J. P. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368462 · Cited by 38 · see citing works
Morphology of action potentials recorded from human nerves using microneurography
Inglis, J. T., Leeper, J. B., Burke, D. J., & Gandevia, S. C. (1996) · Experimental Brain Research · doi:10.1007/bf00228561 · Cited by 34 · see citing works
Wheatley, M., & Stein, R. B. (1992) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(92)90143-2 · Cited by 33 · see citing works
Self-citationA multichannel hook electrode for simultaneous recording of up to 12 nerve filaments
Djupsjöbacka, M., Johansson, H., Bergenheim, M., & Sandström, U. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90058-2 · Cited by 18 · see citing works
Wu, G., Hallin, R. G., & Ekedahl, R. G. (1997) · Experimental Brain Research · doi:10.1007/pl00005646 · Cited by 15 · see citing works
Wu, G., Ekedahl, R. G., & Hallin, R. G. (1998) · Experimental Brain Research · doi:10.1007/s002210050420 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Self-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 358 · see citing works
Self-citationBadia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
Self-citationLong-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176 · see citing works
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · see citing works
Self-citationInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · see citing works
Self-citationBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · see citing works
Self-citationFitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69 · see citing works
Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65 · see citing works
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · see citing works
Combined Analysis of Cortical (EEG) and Nerve Stump Signals Improves Robotic Hand Control
Tombini, M., Rigosa, J., Zappasodi, F., Porcaro, C., Citi, L., Carpaneto, J., Rossini, P. M., & Micera, S. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311408919 · Cited by 41 · see citing works
Blind source separation of peripheral nerve recordings
Tesfayesus, W., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s03 · Cited by 40 · see citing works
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36 · see citing works
Self-citationMetcalfe, B., Chew, D. J., Clarke, C. T., Donaldson, N., & Taylor, J. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.05.003 · Cited by 34 · see citing works
Cheng, J., Jovanović, K., Aoyagi, Y., Bennett, D. J., Han, Y., & Stein, R. B. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1102-0 · Cited by 31 · see citing works
Self-citationImplantation mechanics of tungsten microneedles into peripheral nerve trunks
Yoshida, K., Lewinsky, I., Nielsen, M., & Hylleberg, M. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0175-0 · Cited by 28 · see citing works
Self-citationRecording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23 · see citing works
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003) · Microsurgery · doi:10.1002/micr.10116 · Cited by 22 · see citing works
Micera, S., Rigosa, J., Carpaneto, J., Citi, L., Raspopović, S., Guglielmelli, E., Benvenuto, A., Rossini, L., Pino, G. D., Cavallo, G., et al. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332764 · Cited by 18 · see citing works
Sergi, P. N., Jensen, W., & Yoshida, K. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.11.022 · Cited by 15 · see citing works
Self-citationActivities on PNS neural interfaces for the control of hand prostheses
Carpaneto, J., Cutrone, A., Bossi, S., Sergi, P. N., Citi, L., Rigosa, J., Rossini, P. M., & Micera, S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091148 · Cited by 14 · see citing works
Sergi, P. N., de la Oliva, N., del Valle, J., Navarro, X., & Micera, S. (2021) · Applied Sciences · doi:10.3390/app11188568 · Cited by 14 · see citing works
Clewell, A. E., Qureshi, I., Endres, J. R., Horváth, J., Financsek, I., Neal-Kababick, J., Jade, K. A., & Schauss, A. G. (2010) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2009.12.006 · Cited by 12 · see citing works
Taghlabi, K. M., Cruz-Garza, J. G., Hassan, T., Potnis, O., Bhenderu, L. S. S., Guerrero, J. R., Whitehead, R. E., Wu, Y. C., Luan, L., Xie, C., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad200f · Cited by 8 · see citing works
Bioelectric Medicine and Devices for the Treatment of Spinal Cord Injury
Torregrosa, T., & Koppes, R. A. (2016) · Cells Tissues Organs · doi:10.1159/000446698 · Cited by 7 · see citing works
A data-driven polynomial approach to reproduce the scar tissue outgrowth around neural implants
Sergi, P. N., del Valle, J., de la Oliva, N., Micera, S., & Navarro, X. (2020) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-020-06396-4 · Cited by 8 · see citing works
de Carrizosa, M. A. D., Tena, J. J., Benítez‐Temiño, B., Morado-Díaz, C. J., Pastor, Á. M., & de la Cruz, R. R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.021 · Cited by 7 · see citing works
Kamavuako, E. N., Yoshida, K., & Jensen, W. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.01.006 · Cited by 6 · see citing works
Self-citationMillevolte, A. X. T., Dingle, A. M., Ness, J. P., Novello, J., Zeng, W., Lü, Y., Minor, R. L., Nemke, B. W., Markel, M. D., Suminski, A. J., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.613844 · Cited by 6 · see citing works
Functional Electrical Stimulation
Venkatasubramanian, G., Jung, R., & Sweeney, J. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd119 · Cited by 6 · see citing works
Neural prostheses and biomedical microsystems in neurological rehabilitation
Koch, K. P. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_56 · Cited by 5 · see citing works
Development of a Novel Intrafascicular Nerve Electrode
Mitsui, M., Suzuki, T., Mabuchi, K., Takiura, K., Saito, I., Chinzei, T., Mochizuki, S., Isoyama, T., Abe, Y., & Imachi, K. (2005) · ASAIO Journal · doi:10.1097/01.mat.0000172123.18016.16 · Cited by 2 · see citing works
Selectivity of the TIME Implantable Nerve Electrode
Badía, J., Harreby, K. R., Kundu, A., Boretius, T., Stieglitz, T., Jensen, W., & Navarro, X. (2022) · River Publishers eBooks · doi:10.1201/9781003337973-7 · Cited by 2 · see citing works
Flexible intra-fascicular nerve electrodes for the recordings of autonomous nerves
Mitsui, M., Takeuchi, S., Suzuki, T., Ohkura, M., & Mabuchi, K. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196757 · Cited by 1 · see citing works
Coatings for Microneural Implants: Electrical Considerations
Olczak, K. P., & Otto, K. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_7 · Cited by 1 · see citing works
Kundu, A., Patrick, E. E., Currlin, S., Madler, R., Delgado, F., Fahmy, A., Verplancke, R., Ballini, M., Braeken, D., de Beeck, M. O., et al. (2024) · Micromachines · doi:10.3390/mi15020280 · Cited by 1 · see citing works
Regenerative Neural Electrodes
Guzman, G., Rafaqut, M. S., Park, S., & Choi, P. Y. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_11 · Cited by 1 · see citing works
Polymer-Based Implantable Electrodes: State of the Art and Future Prospects
Koch, K. P., Ramachandran, A., Poppendieck, W., Feili, D., & Hoffmann, K. (2006) · MRS Proceedings · doi:10.1557/proc-0926-cc06-01 · Cited by 1 · see citing works
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1 · see citing works
Self-citationLago, N. (2006) · TDX (Tesis Doctorals en Xarxa)
Array of Varying-Length Microelectrodes Selective Stimulation of Cat Sciatic Nerve Using an
Stein, R. B., Normann, R. A., Dhillon, G. S., Krüger, T. B., Sandhu, J. S., Horch, K. W., Caparso, A., Durand, D. M., & Mansour, J. M. (2015)
Self-citationNovel In Silico Strategies to Model the In Vivo Nerve Scarring Around Implanted Parylene C Devices
Sergi, P. N., del Valle, J., Stieglitz, T., Navarro, X., & Micera, S. (2024) · Applied Sciences · doi:10.3390/app142210741
An arbitrary waveform neurostimulator for preclinical studies: design and verification
Guzmán-Miranda, H., & Barriga‐Rivera, A. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03241-6
- Authors
- Yoshida, K., Jovanović, K., & Stein, R. B.
- Affiliations
- Aalborg University (DK)
- University of Alberta (CA)
- Corresponding author
- Yoshida, Ken
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 96
- Issue
- 1
- Pages
- 47-55
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W1984905989
- Cited by
- 49
- References
- 19
- Citations by year
- 2024: 4 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 3 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 4 · 2013: 1 · 2012: 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Danmarks Grundforskningsfond
- Fondation pour la Recherche Médicale
- Medical Research Council
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- intrafascicular electrodes, mudpuppy, spinal nerve roots, fine-wire electrodes, neurostimulation, compound action potential, cutaneous mechanoreceptors, evoked activity, nerve conduction velocity
- MeSH terms
- Action Potentials, Animals, Electric Stimulation, Electrodes, Implanted, Electromyography, Evoked Potentials, Somatosensory, Forelimb, Necturus, Nerve Crush, Neural Conduction, Physical Stimulation, Spinal Nerve Roots
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review