The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Water proton MR properties of human blood at 1.5 Tesla: Magnetic susceptibility,T1,T2,T, and non‐Lorentzian signal behavior
Open accessAbstract
Accurate knowledge of the magnetic properties of human blood is required for the precise modeling of functional and vascular flow‐related MRI. Herein are reported determinations of the relaxation parameters of blood, employing in vitro samples that are well representative of human blood in situ. The envelope of the blood 1 H 2 O free‐induction decay signal magnitude during the first 100 msec following a spin echo at time TE is well‐ described empirically by an expression of the form,S(t) =So· exp{–R· (t– TE) –AR* · (t– TE)2}. The relaxation parameters AR* and Rincrease as a function of the square of the susceptibility difference between red blood cell and plasma and depend on the spin‐echo time. The Gaussian component,AR*, should be recognized in accurate modeling of MRI phenomena that depend upon the magnetic state of blood. The magnetic susceptibility difference between fully deoxygenated and fully oxygenated red blood cells at 37°C is 0.27 ppm, as determined independently by MR and superconducting quantum interference device (SQUID) measurements. This value agrees well with the 1936 report of Pauling and Coryell (Proc Natl Acad Sci USA 1936;22:210–216), but is substantially larger than that frequently used in MRI literature. Magn Reson Med 45:533–542, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Self-citationThe Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
THE SUSPENSION STABILITY OF THE BLOOD
Fåhraeus, R. (1929) · Physiological Reviews · doi:10.1152/physrev.1929.9.2.241 · Cited by 938
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 546
Hemoglobin: Structure, function, evolution, and pathology
Brunori, M. (1984) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(84)90080-x · Cited by 509
van Zijl, P. C. M., Eleff, S. M., Ulatowski, J. A., Oja, J. M. E., Uluǧ, A. M., Traystman, R. J., & Kauppinen, R. A. (1998) · Nature Medicine · doi:10.1038/nm0298-159 · Cited by 501
Hemoglobin : structure, function, evolution, and pathology
Dickerson, R. E., & Geis, I. (1983) · Andalas University Repository (Andalas University) · Cited by 451
Bayesian Spectrum Analysis and Parameter Estimation
Guber, M. H. J. (1990) · Technometrics · doi:10.1080/00401706.1990.10484646 · Cited by 440
Bayesian Spectrum Analysis and Parameter Estimation
Bretthorst, G. L. (1988) · Lecture Notes in Statistics · doi:10.1007/978-1-4684-9399-3 · Cited by 428
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Chu, K. ‐. C., Xu, Y., Balschi, J. A., & Springer, C. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130207 · Cited by 373
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Quantitation of intrinsic magnetic susceptibility‐related effects in a tissue matrix. Phantom study
Yablonskiy, D. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390312 · Cited by 245
Self-citationSakai, F., Nakazawa, K., Tazaki, Y., Ishii, K., Hino, H., Igarashi, H., & Kanda, T. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.27 · Cited by 242
NMR relaxation times of blood: dependence on field strength, oxidation state, and cell integrity.
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · PubMed · Cited by 213
NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198707000-00025 · Cited by 195
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Chiro, G. D. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 138
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Blood oxygen saturation assessment in vivo using T2 * estimation
Li, D., Wang, Y., & Waight, D. J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390503 · Cited by 98
NMR relaxation rates and blood oxygenation level
Meyer, M. ‐., Yu, O., Eclancher, B., Grucker, D., & Chambron, J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340215 · Cited by 83
Packer, K. J. (1973) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(73)90186-8 · Cited by 77
Proton Transverse Nuclear Magnetic Relaxation in Oxidized Blood: a Numerical Approach
Gillis, P., Petö, S., Moiny, F., Mispelter, J., & Cuénod, C. A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330114 · Cited by 60
Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin
CERDONIO, M., Congiu‐Castellano, A., Calabrese, L., Morante, S., Pispisa, B., & Vitale, S. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.10.4916 · Cited by 58
In vivo correlation between blood T2 and orrygen saturation
Li, D., Waight, D. J., & Wang, Y. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080609 · Cited by 50
Ye, F. Q., & Allen, P. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340510 · Cited by 46
Reexamination of the evidence for paramagnetism in oxy- and carbonmonoxyhemoglobins.
CERDONIO, M., Morante, S., Torresani, D., Vitale, S., DeYoung, A., & Noble, R. W. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.1.102 · Cited by 45
Gasparovic, C., & Matwiyoff, N. A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910260208 · Cited by 44
Matwiyoff, N. A., Gasparovic, C., Mazurchuk, R., & Matwiyoff, G. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90102-8 · Cited by 35
Chien, D., Levin, D. L., & Anderson, C. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320419 · Cited by 35
Principles of Susceptibility Contrast-Based Functional MRI: The Sign of the Functional MRI Response
SPRINGER, C. S. J., Pályka, I., Patlak, C. S., & Huang, W. C. W. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_9 · Cited by 18
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, J., Liu, T., de Rochefort, L., Ledoux, J., Khalidov, I., Chen, W., Tsiouris, A. J., Wisnieff, C., Spincemaille, P., Prince, M. R., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.082 · Cited by 498
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Metadata
- Authors
- Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-03-27
- Volume
- 45
- Issue
- 4
- Pages
- 533-542
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2060182774
- Cited by
- 461
- References
- 37
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.