The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
MR Contrast Due to Microscopically Heterogeneous Magnetic Susceptibility: Numerical Simulations and Applications to Cerebral Physiology
Abstract
We calculate the effects of subvoxel variations in magnetic susceptibility on MR image intensity for spin‐echo (SE) and gradient‐echo (GE) experiments for a range of microscopic physical parameters. The model used neglects the overlap of gradients from one magnetic inclusion to the next, and so is valid for low volume fractions and weak perturbations of the magnetic field. Transverse relaxation is predicted to deviate significantly from linear exponential decay in both SE and GE at a particle radius of 2.5 μm. Calculated changes in transverse relaxation rates for SE and GE increase linearly with volume fraction of high‐susceptibility regions of 5 μm diameter, but increase with about the 3/2 power of volume fraction of regions with 15 μm spacing between centers. This sensitivity to the actual size and spacing of magnetized regions may allow them to be measured on the basis of contrast, without being resolved in images. GE and SE decay rates are approximately twice as sensitive to long cylinders of 5 μm diameter than to spheres of the same size, for diffusion constants of 2.5 μm 2/ms. Calculated changes in transverse decay rates increase with approximately the square of field and susceptibility variation for 5‐μm spheres and a diffusion constant of 2.5 μm 2/ms. This exponent is smaller for cylindrical magnetized regions of the same size, and also depends on the diffusion constant. We discuss possible applications of our theoretical results to the analysis of the effects of high‐susceptibility contrast agents in brain. Experimental data from the literature are compared with calculated signal changes according to the model. The monotonic dependence of decay rates on the volume of distribution of the contrast agent suggests that cerebral blood volume and flow could be measured using MR contrast. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Intracranial hematomas: imaging by high-field MR.
Gomori, J. M., Grossman, R. I., Goldberg, H. I., Zimmerman, R. A., & Bilaniuk, L. T. (1985) · Radiology · doi:10.1148/radiology.157.1.4034983 · Cited by 731
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Self-citationSusceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Freed, J. H. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436302 · Cited by 442
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Blood-brain barrier in physiology and medicine
O'Brien, M. D. (1977) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(77)90141-1 · Cited by 351
Pawlik, G., Rackl, A., & Bing, R. J. (1981) · Brain Research · doi:10.1016/0006-8993(81)90619-3 · Cited by 311
Evidence of the Limitations of Water as a Freely Diffusible Tracer in Brain of the Rhesus Monkey
EICHLING, J. O., RAICHLE, M. E., GRUBB, R. L., & TER-POGOSSIAN, M. M. (1974) · Circulation Research · doi:10.1161/01.res.35.3.358 · Cited by 278
Spin-Echo Decay of Spins Diffusing in a Bounded Region
Robertson, B. (1966) · Physical Review · doi:10.1103/physrev.151.273 · Cited by 255
Ferrite particles: a superparamagnetic MR contrast agent for the reticuloendothelial system.
Saini, S., Stark, D. D., Hahn, P. F., Wittenberg, J., Brady, T. J., & Ferrucci, J. T. (1987) · Radiology · doi:10.1148/radiology.162.1.3786765 · Cited by 230
Self-citationThe effects of iron oxides on proton relaxivity
Josephson, L., Lewis, J., Jacobs, P., Hahn, P. F., & Stark, D. D. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90088-4 · Cited by 218
Ferromagnetic particles as contrast agents for magnetic resonance imaging of liver and spleen
Dias, M. H. M., & Lauterbur, P. C. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030218 · Cited by 180
Studies of diffusion in random fields produced by variations in susceptibility
Majumdar, S., & Gore, J. C. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90155-2 · Cited by 161
MR of hemorrhage: a new approach.
Edelman, R. R., Johnson, K., Buxton, R. B., Shoukimas, G. M., Rosen, B. R., Davis, K. R., & Brady, T. J. (1986) · PubMed · Cited by 142
Self-citationContrast in Rapid MR Imaging: T1− and T2-Weighted Imaging
Buxton, R. B., Edelman, R. R., Rosen, B. R., Wismer, G. L., & Brady, T. J. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198701000-00003 · Cited by 139
Self-citationFiltration and diffusion of water across the blood-brain barrier in man
Paulson, O. B., Hertz, M. M., Bolwig, T. G., & Lassen, N. A. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90120-0 · Cited by 133
Nuclear Magnetic Resonance Technology for Medical Studies
Budinger, T. F., & Lauterbur, P. C. (1984) · Science · doi:10.1126/science.6385252 · Cited by 127
Clinical Magnetic Susceptibility Mapping of the Brain
YOUNG, I. R., Khenia, S., Thomas, D. G. T., Davis, C. H., Gadian, D. G., Cox, I. J., Ross, B. D., & Bydder, G. M. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198701000-00002 · Cited by 100
Der Translationsanteil der Protonenrelaxation in wäßrigen Lösungen paramagnetischer Ionen
Pfeifer, H. (1961) · Annalen der Physik · doi:10.1002/andp.19614630102 · Cited by 94
Packer, K. J. (1973) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(73)90186-8 · Cited by 77
Cerebral Blood Flow and Oxygen Consumption in the Rat Brain during Extreme Hypercarbia
Berntman, L., Dahlgren, N., & Siesjö, B. K. (1979) · Anesthesiology · doi:10.1097/00000542-197904000-00004 · Cited by 70
Dynamic digital subtraction imaging using fast low-angle shot MR movie sequence.
Haase, A., Matthaei, D., Hänicke, W., & Frahm, J. (1986) · Radiology · doi:10.1148/radiology.160.2.3523597 · Cited by 57
Ahn, C. B., Lee, S. Y., Nalcioglu, O., et al. (1986) · Medical Physics · doi:10.1118/1.595850 · Cited by 48
Cited by
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Self-citation
Metadata
- Authors
- Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-02
- Volume
- 17
- Issue
- 2
- Pages
- 336-347
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2011575415
- Cited by
- 356
- References
- 28
- FWCI
- 19.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.