The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
MR Contrast Due to Microscopically Heterogeneous Magnetic Susceptibility: Numerical Simulations and Applications to Cerebral Physiology
Abstract
We calculate the effects of subvoxel variations in magnetic susceptibility on MR image intensity for spin‐echo (SE) and gradient‐echo (GE) experiments for a range of microscopic physical parameters. The model used neglects the overlap of gradients from one magnetic inclusion to the next, and so is valid for low volume fractions and weak perturbations of the magnetic field. Transverse relaxation is predicted to deviate significantly from linear exponential decay in both SE and GE at a particle radius of 2.5 μm. Calculated changes in transverse relaxation rates for SE and GE increase linearly with volume fraction of high‐susceptibility regions of 5 μm diameter, but increase with about the 3/2 power of volume fraction of regions with 15 μm spacing between centers. This sensitivity to the actual size and spacing of magnetized regions may allow them to be measured on the basis of contrast, without being resolved in images. GE and SE decay rates are approximately twice as sensitive to long cylinders of 5 μm diameter than to spheres of the same size, for diffusion constants of 2.5 μm 2/ms. Calculated changes in transverse decay rates increase with approximately the square of field and susceptibility variation for 5‐μm spheres and a diffusion constant of 2.5 μm 2/ms. This exponent is smaller for cylindrical magnetized regions of the same size, and also depends on the diffusion constant. We discuss possible applications of our theoretical results to the analysis of the effects of high‐susceptibility contrast agents in brain. Experimental data from the literature are compared with calculated signal changes according to the model. The monotonic dependence of decay rates on the volume of distribution of the contrast agent suggests that cerebral blood volume and flow could be measured using MR contrast. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Intracranial hematomas: imaging by high-field MR.
Gomori, J. M., Grossman, R. I., Goldberg, H. I., Zimmerman, R. A., & Bilaniuk, L. T. (1985) · Radiology · doi:10.1148/radiology.157.1.4034983 · Cited by 731
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Self-citationSusceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Freed, J. H. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436302 · Cited by 442
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Cited by
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Self-citationØstergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationFunctional analysis of human MT and related visual cortical areas using magnetic resonance imaging
Tootell, R., Reppas, J., Kwong, K., Malach, R., Born, R., Brady, T., Rosen, B., & Belliveau, J. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-04-03215.1995 · Cited by 1,415
Self-citationTheory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Self-citationØstergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Self-citationMicroscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Self-citationParametric Analysis of fMRI Data Using Linear Systems Methods
Cohen, M. S. (1997) · NeuroImage · doi:10.1006/nimg.1997.0278 · Cited by 714
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Physiological noise in oxygenation‐sensitive magnetic resonance imaging
Krüger, G., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1240 · Cited by 629
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Warmuth, C., Günther, M., & Zimmer, C. (2003) · Radiology · doi:10.1148/radiol.2282020409 · Cited by 364
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
NMR imaging of changes in vascular morphology due to tumor angiogenesis
Dennie, J., Mandeville, J. B., Boxerman, J. L., Packard, S. D., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400602 · Cited by 337
Self-citationPitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Self-citationTropr�s, I., Grimault, S., Vaeth, A., Grillon, E., Julien, C., Payen, J.-F., Lamalle, L., & D�corps, M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<397::aid-mrm1052>3.0.co;2-3 · Cited by 333
Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325
Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
Self-citationPrinciples of cerebral perfusion imaging by bolus tracking
Østergaard, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20460 · Cited by 289
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
On T2‐shortening by strongly magnetized spheres: A partial refocusing model
Gillis, P., Moiny, F., & Brooks, R. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10059 · Cited by 270
Localization of brain function using magnetic resonance imaging
COHEN, M., & BOOKHEIMER, S. (1994) · Trends in Neurosciences · doi:10.1016/0166-2236(94)90055-8 · Cited by 257
Cognitive stimulation with the Wisconsin Card Sorting Test: functional MR imaging at 1.5 T.
Mentzel, H. J., Gaser, C., Volz, H. P., Rzanny, R., Häger, F., Sauer, H., & Kaiser, W. A. (1998) · Radiology · doi:10.1148/radiology.207.2.9577487 · Cited by 49
Metadata
- Authors
- Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-02
- Volume
- 17
- Issue
- 2
- Pages
- 336-347
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2011575415
- Cited by
- 356
- References
- 28
- FWCI
- 19.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.