The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Observation of a fast response in functional MR
Abstract
A spectroscopic MR technique was used to investigate the time course of the MR signal following a single visual stimulus. Gated experiments demonstrate there is an early response (500 ms after stimulus) leading to a reduction of the MR signal by −0.25% (P = 0.02), whereas a slower response (>1500 ms after stimulus) results in a signal increase of +0.59% (P = 0.01). The fast negative response may be attributed to increased oxygen consumption, followed by a slower vascular response with overcompensation in blood oxygenatioln. This explanation would be in agreement with the blood oxygenation level dependent (BOLD) contrast mechanism considered the basis of functional MR. However, other physiological events might also be responsible for the signal drop observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Cited by
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Modeling the hemodynamic response to brain activation
Buxton, R. B., Uludağ, K., Dubowitz, D. J., & Liu, T. T. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.013 · Cited by 1,229
What does fMRI tell us about neuronal activity?
Heeger, D. J., & Ress, D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn730 · Cited by 1,085
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Functional neuroimaging of normal human sleep by positron emission tomography
Maquet (2000) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2000.00214.x · Cited by 581
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Event-related functional MRI: Past, present, and future
Rosen, B. R., Buckner, R. L., & Dale, A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.773 · Cited by 526
Evidence of a Cerebrovascular Postarteriole Windkessel with Delayed Compliance
Mandeville, J. B., Marota, J. J. A., Ayata, C., Zaharchuk, G., Moskowitz, M. A., Rosen, B. R., & Weisskoff, R. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199906000-00012 · Cited by 520
Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
Menon, R. S., Ogawa, S., Hu, X., Strupp, J. P., Anderson, P., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330323 · Cited by 421
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
High-resolution mapping of iso-orientation columns by fMRI
Kim, D.-S., Duong, T. Q., & Kim, S.-G. (2000) · Nature Neuroscience · doi:10.1038/72109 · Cited by 393
Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
Posse, S., Wiese, S., Gembris, D., Mathiak, K., Kessler, C., Grosse-Ruyken, M.-L., Elghahwagi, B., Richards, T., Dager, S. R., & Kiselev, V. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<87::aid-mrm13>3.0.co;2-o · Cited by 388
Human Ocular Dominance Columns as Revealed by High-Field Functional Magnetic Resonance Imaging
Cheng, K., Waggoner, R. A., & Tanaka, K. (2001) · Neuron · doi:10.1016/s0896-6273(01)00477-9 · Cited by 383
Jasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Investigating neural–hemodynamic coupling and the hemodynamic response function in the awake rat
Martin, C., Martindale, J., Berwick, J., & Mayhew, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.021 · Cited by 262
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Hu, X., Le, T. H., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370612 · Cited by 255
Zhu, X., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1267 · Cited by 92
Metadata
- Authors
- Ernst, T., & Hennig, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-07
- Volume
- 32
- Issue
- 1
- Pages
- 146-149
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2004874475
- Cited by
- 240
- References
- 3
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.