The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Mr perfusion studies with t1‐weighted echo planar imaging
Abstract
The T1 perfusion model has worked well in brain functional studies where flow changes are measured. Using selective and nonselective inversion pulses, a new method has been developed to study steady‐state brain blood flow. The authors obtained flow‐sensitive images using selective inversion and flow‐insensitive images using nonselective inversion. Subtraction of flow‐insensitive images from flow‐sensitive images gave us flow‐weighted images with good gray‐white flow contrast in cortical gray matter as well as in the thalamus and basal ganglia. Fitting T1 S of flow‐insensitive and flow‐sensitive images allowed us to obtain preliminary results of brain blood flow maps. Two specific problems can seriously affect the accuracy of the brain blood flow values and the gray‐white flow contrast of brain blood flow maps. These are the problems of the partial volume effect of CSF and gray matter, and the difference between blood T1 and white matter T1. The authors discuss in detail the character of these problems and present a number of approaches to manage such problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Self-citationDetre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Blood-brain barrier permeability of 11C-labeled alcohols and 15O-labeled water
Raichle, M., Eichling, J., Straatmann, M., Welch, M., Larson, K., & Ter-Pogossian, M. (1976) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1976.230.2.543 · Cited by 262
Functional Magnetic Resonance Imaging with Echo Planar Imaging
Kwong, K. K. (1996) · Functional MRI · doi:10.1007/978-88-470-2194-5_16 · Cited by 184
Self-citationMR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., & Conolly, S. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 171
Mechanisms of Contrast in NMR Imaging
Wehrli, F. W., MacFall, J. R., Shutts, D., Breger, R. K., & Herfkens, R. J. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00001 · Cited by 129
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Self-citationAlsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Swain, R. A., Harris, A. B., Wiener, E. C., Dutka, M. V., Morris, H. D., Theien, B. E., Konda, S., Engberg, K., Lauterbur, P. C., & Greenough, W. T. (2003) · Neuroscience · doi:10.1016/s0306-4522(02)00664-4 · Cited by 655
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Wu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Spatiotemporal mapping of brain activity by integration of multiple imaging modalities
Dale, A. M., & Halgren, E. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00197-5 · Cited by 342
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
“, 1998), and selective/ non-selective inversion (Kim, 1995; Kwong et al., 1995).”
MethodKim, S.-G., Rostrup, E., Larsson, H. B. W., Ogawa, S., & Paulson, O. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1152::aid-mrm11>3.0.co;2-t · Cited by 268
Efficiency of inversion pulses for background suppressed arterial spin labeling
Garcia, D. M., Duhamel, G., & Alsop, D. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20556 · Cited by 260
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Self-citationPerfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Imaging brain deoxyglucose uptake and metabolism by glucoCEST MRI
Nasrallah, F. A., Pagès, G., Kuchel, P. W., Golay, X., & Chuang, K.-H. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.79 · Cited by 179
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
Microbubbles as a novel contrast agent for brain MRI
Cheung, J. S., Chow, A. M., Guo, H., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.037 · Cited by 36
Biswal (1997) · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<165::aid-nbm454>3.0.co;2-7
Metadata
- Authors
- Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 34
- Issue
- 6
- Pages
- 878-887
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1996498530
- Cited by
- 477
- References
- 7
- FWCI
- 19.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.