The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging
Abstract
Chemical shift based methods are often used to achieve uniform water–fat separation that is insensitive to Bo inhomogeneities. Many spin‐echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time‐dependent phase shifts caused by water–fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water–fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed “iterative decomposition of water and fat with echo asymmetric and least‐squares estimation” (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least‐squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2π/3, with the middle echo centered at π/2+π k (k = any integer), i.e., (–π/6+π k, π/2+π k, 7π/6+π k). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil–water phantom was observed, demonstrating that the iterative least‐squares decomposition method is an efficient estimator. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Fundamentals of statistical signal processing: Estimation theory
Prasad, K. V. (1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90195-3 · Cited by 7,902
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
The utility of radiological imaging in nonalcoholic fatty liver disease
Saadeh, S., Younossi, Z. M., Remer, E. M., Gramlich, T., Ong, J. P., Hurley, M., Mullen, K. D., Cooper, J. N., & Sheridan, M. J. (2002) · Gastroenterology · doi:10.1053/gast.2002.35354 · Cited by 2,110
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationSimultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
Self-citationState-of-the-Art Adrenal Imaging
Mayo-Smith, W. W., Boland, G. W., Noto, R. B., & Lee, M. J. (2001) · RadioGraphics · doi:10.1148/radiographics.21.4.g01jl21995 · Cited by 359
Quantitative evaluation of several partial fourier reconstruction algorithms used in mri
McGibney, G., Smith, M. R., Nichols, S. T., & Crawley, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300109 · Cited by 313
Ma, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20146 · Cited by 249
Cramér–Rao bounds for three‐point decomposition of water and fat
Pineda, A. R., Reeder, S. B., Wen, Z., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20623 · Cited by 215
Self-citationIs TrueFISP a gradient‐echo or a spin‐echo sequence?
Scheffler, K., & Hennig, J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10351 · Cited by 197
Fat‐suppressed steady‐state free precession imaging using phase detection
Hargreaves, B. A., Vasanawala, S. S., Nayak, K. S., Hu, B. S., & Nishimura, D. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10488 · Cited by 107
The short TI inversion recovery sequence—An approach to MR imaging of the abdomen
Bydder, G. M., Pennock, J. M., Steiner, R. E., Khenia, S., Payne, J. A., & YOUNG, I. R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90354-6 · Cited by 100
Reeder, S. B., Pelc, N. J., Alley, M. T., & Gold, G. E. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800357 · Cited by 73
Self-citation
Cited by
Cox, L. M., Yamanishi, S., Sohn, J., Alekseyenko, A. V., Leung, J. M., Cho, I., Kim, S. G., Li, H., Gao, Z., Mahana, D., et al. (2014) · Cell · doi:10.1016/j.cell.2014.05.052 · Cited by 1,859
Antibiotics in early life alter the murine colonic microbiome and adiposity
Cho, I., Yamanishi, S., Cox, L., Methé, B. A., Zavadil, J., Li, K., Gao, Z., Mahana, D., Raju, K., Teitler, I., et al. (2012) · Nature · doi:10.1038/nature11400 · Cited by 1,613
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationSchwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citation
Metadata
- Authors
- Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-08-09
- Volume
- 54
- Issue
- 3
- Pages
- 636-644
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2137281603
- Cited by
- 706
- References
- 20
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.