CoChat

Susceptibility‐weighted imaging: current status and future directions

Open access
Liu, Saifeng, Buch, Sagar, Chen, Yongsheng, Choi, Hyun‐Seok, Dai, Yongming, Habib, Charbel, Hu, Jiani, Jung, Joon‐Yong, Luo, Yu, Utriainen, David, Wang, Meiyun, Wu, Dongmei, Xia, Shuang, Haacke, E. Mark · 2017 · NMR in Biomedicine
Cited by 170

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Susceptibility‐weighted imaging (SWI) is a method that uses the intrinsic nature of local magnetic fields to enhance image contrast in order to improve the visibility of various susceptibility sources and to facilitate diagnostic interpretation. It is also the precursor to the concept of the use of phase for quantitative susceptibility mapping (QSM). Nowadays, SWI has become a widely used clinical tool to image deoxyhemoglobin in veins, iron deposition in the brain, hemorrhages, microbleeds and calcification. In this article, we review the basics of SWI, including data acquisition, data reconstruction and post‐processing. In particular, the source of cusp artifacts in phase images is investigated in detail and an improved multi‐channel phase data combination algorithm is provided. In addition, we show a few clinical applications of SWI for the imaging of stroke, traumatic brain injury, carotid vessel wall, siderotic nodules in cirrhotic liver, prostate cancer, prostatic calcification, spinal cord injury and intervertebral disc degeneration. As the clinical applications of SWI continue to expand both in and outside the brain, the improvement of SWI in conjunction with QSM is an important future direction of this technology. Copyright © 2016 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.3552

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 167

  1. 10.1002/ima.1850060204 · DOI · Paper page
  2. 10.1002/(SICI)1097-0193(1997)5:5<341::AID-HBM2>3.0.CO;2-3 · DOI
  3. 10.1148/radiology.204.1.9205259 · DOI · Paper page
  4. 10.1007/BF02662513 · DOI
  5. Reichenbach JR, 2000, High‐resolution MR venography at 3.0 Tesla. J. Comput. Assist, Tomogr., 24, 949
  6. 10.1007/s002340000503 · DOI
  7. 10.1002/nbm.722 · DOI · Paper page
  8. 10.1002/jmri.24768 · DOI · Paper page
  9. 10.1002/jmri.21758 · DOI
  10. 10.3174/ajnr.A3818 · DOI
  11. 10.1002/jmri.22987 · DOI · Paper page
  12. 10.1002/jmri.21617 · DOI · Paper page
  13. 10.1002/jmri.22687 · doi:10.1002/jmri.22687
  14. 10.1002/jmri.21859 · DOI
  15. 10.1016/j.mri.2010.10.016 · DOI
  16. 10.1002/jmri.22607 · DOI
  17. 10.1371/journal.pone.0057691 · DOI
  18. Chen J, 2013, Assessment of intratumoral micromorphology for patients with clear cell renal cell carcinoma using susceptibility‐weighted imaging, PLoS One, 8
  19. 10.1002/mrm.25350 · DOI
  20. 10.1002/jmri.24413 · DOI
  21. 10.1002/mrm.24920 · DOI
  22. 10.1002/jmri.21693 · DOI · Paper page
  23. 10.1002/mrm.25878 · DOI
  24. 10.3174/ajnr.A1400 · DOI · Paper page
  25. 10.1088/0031-9155/36/6/002 · doi:10.1088/0031-9155/36/6/002
  26. 10.1002/mrm.24759 · DOI
  27. 10.1016/j.neuroimage.2010.10.070 · DOI · Paper page
  28. 10.1002/nbm.1670 · DOI · Paper page
  29. 10.1002/nbm.3056 · DOI · Paper page
  30. 10.1002/nbm.3064 · DOI · Paper page
  31. 10.1109/TMI.2014.2361764 · DOI
  32. 10.1002/mrm.24457 · DOI
  33. 10.1002/jmri.21995 · DOI
  34. 10.1002/jmri.21447 · DOI
  35. 10.1002/9780470905203 · DOI
  36. 10.1002/mrm.24937 · DOI
  37. 10.1002/jmri.1880070203 · DOI · Paper page
  38. 10.1002/jmri.21833 · DOI
  39. 10.1002/jmri.21673 · DOI
  40. 10.1016/j.mri.2012.02.008 · DOI
  41. 10.1002/mrm.21581 · DOI
  42. 10.1002/jmri.24128 · DOI
  43. 10.1002/mrm.24405 · DOI · Paper page
  44. 10.1002/mrm.24272 · DOI · Paper page
  45. 10.1002/jmri.24728 · DOI
  46. 10.1002/mrm.10171 · DOI · Paper page
  47. 10.1016/j.neuroimage.2007.10.037 · DOI · Paper page
  48. 10.1002/mrm.22753 · DOI · Paper page
  49. 10.1002/mrm.1910160203 · DOI · Paper page
  50. 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S · DOI · Paper page
  51. 10.1002/(SICI)1522-2594(200005)43:5<682::AID-MRM10>3.0.CO;2-G · doi:10.1002/(sici)1522-2594(200005)43:5<682::aid-mrm10>3.0.co;2-g
  52. 10.1002/mrm.10092 · DOI
  53. 10.1002/mrm.24932 · DOI
  54. 10.1007/978-3-540-89208-3_192 · DOI
  55. 10.1118/1.4905163 · DOI
  56. LiuS YeY BuchS HaackeEM.Multi‐channel data combination with linear phase baseline correction.Proceedings of the 23rd Annual Meeting ISMRM Toronto ON Canada 2015;3309.
  57. 10.1364/AO.46.006623 · DOI · Paper page
  58. 10.1002/jmri.22276 · DOI · Paper page
  59. 10.1002/mrm.24384 · DOI · Paper page
  60. 10.1097/00004647-200009000-00002 · DOI · Paper page
  61. Heiss W‐D, 2011, The ischemic penumbra: correlates in imaging and implications for treatment of ischemic stroke. The Johann Jacob Wepfer award 2011. Cerebrovasc. Dis, Basel Switz., 32, 307
  62. 10.1007/s12975-011-0141-x · DOI
  63. 10.1148/radiol.2232010673 · DOI · Paper page
  64. 10.1097/01.WCB.0000141557.32867.6B · doi:10.1097/01.wcb.0000141557.32867.6b
  65. 10.1161/01.STR.0000166181.86928.8b · DOI · Paper page
  66. 10.1038/jcbfm.2008.56 · DOI
  67. 10.1038/jcbfm.2011.67 · doi:10.1038/jcbfm.2011.67
  68. 10.1002/mrm.10576 · DOI
  69. 10.1161/STROKEAHA.114.008154 · DOI
  70. 10.1161/01.STR.0000133341.74387.96 · DOI · Paper page
  71. 10.1016/j.jns.2009.08.064 · DOI
  72. 10.1016/j.neurad.2010.12.006 · DOI
  73. 10.1007/s00415-010-5843-6 · doi:10.1007/s00415-010-5843-6
  74. 10.1007/s00330-012-2387-4 · DOI
  75. 10.1016/j.jstrokecerebrovasdis.2012.12.009 · doi:10.1016/j.jstrokecerebrovasdis.2012.12.009
  76. 10.1016/j.neurad.2013.04.002 · doi:10.1016/j.neurad.2013.04.002
  77. 10.1016/j.ejrad.2014.05.001 · DOI
  78. 10.3174/ajnr.A4017 · DOI
  79. 10.1016/j.neurad.2014.07.002 · DOI
  80. 10.1159/000342148 · doi:10.1159/000342148
  81. 10.1016/j.mri.2014.08.012 · DOI
  82. 10.4103/0028-3886.96389 · doi:10.4103/0028-3886.96389
  83. 10.1016/j.jstrokecerebrovasdis.2015.01.021 · doi:10.1016/j.jstrokecerebrovasdis.2015.01.021
  84. 10.3174/ajnr.A0786 · DOI · Paper page
  85. 10.1016/j.crad.2008.04.022 · DOI
  86. 10.1016/j.acra.2007.05.013 · DOI
  87. 10.1161/STROKEAHA.110.599837 · DOI · Paper page
  88. 10.1007/s00062-012-0185-7 · DOI
  89. 10.1161/STROKEAHA.113.002267 · DOI · Paper page
  90. 10.3174/ajnr.A4248 · DOI · Paper page
  91. 10.1016/j.mri.2011.02.028 · DOI
  92. 10.1007/s00062-015-0458-z · DOI
  93. 10.1118/1.3481505 · DOI · Paper page
  94. 10.1371/journal.pone.0122329 · DOI
  95. 10.3174/ajnr.A1355 · DOI · Paper page
  96. 10.1002/jmri.22513 · DOI · Paper page
  97. 10.1002/jmri.20404 · DOI · Paper page
  98. 10.1002/jmri.22001 · DOI · Paper page
  99. 10.1016/j.jns.2012.05.052 · DOI
  100. 10.1007/s00401-009-0615-z · DOI · Paper page
  101. Haacke EM, 2007, Imaging cerebral amyloid angiopathy with susceptibility‐weighted imaging, Am. J. Neuroradiol., 28, 316
  102. 10.1089/neu.2013.3021 · DOI
  103. 10.1148/radiol.2015150160 · DOI
  104. 10.3109/02699052.2012.694563 · DOI
  105. 10.4103/1673-5374.135330 · DOI
  106. 10.1089/neu.2014.3856 · DOI
  107. 10.1007/s11547-013-0328-1 · DOI
  108. 10.1016/j.jstrokecerebrovasdis.2015.08.003 · DOI
  109. 10.1001/jamaneurol.2015.1359 · DOI · Paper page
  110. Ingall T, 2004, Stroke—incidence, mortality, morbidity and risk, J. Insur. Med., 36, 143
  111. European Carotid Surgery Trialists' Collaborative Group, 1998, Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST), Lancet Lond. Engl., 351, 1379, 10.1016/S0140-6736(97)09292-1 · DOI · Paper page
  112. 10.1016/j.jcmg.2012.01.012 · DOI · Paper page
  113. 10.1056/NEJMoa1012592 · DOI · Paper page
  114. 10.1161/01.CIR.103.17.2171 · DOI · Paper page
  115. 10.1148/radiol.10101008 · DOI
  116. 10.1148/radiol.2342032101 · DOI · Paper page
  117. 10.1161/01.CIR.0000028591.44554.F9 · DOI · Paper page
  118. 10.1148/radiol.2412051336 · DOI · Paper page
  119. 10.1016/j.jacc.2011.01.056 · doi:10.1016/j.jacc.2011.01.056
  120. 10.1148/radiol.12120499 · DOI
  121. 10.1186/1532-429X-16-22 · DOI
  122. 10.1002/jmri.21791 · DOI
  123. 10.1016/j.mric.2008.12.002 · DOI · Paper page
  124. 10.1097/RMR.0b013e3181ea2853 · DOI
  125. 10.1002/jmri.23734 · DOI
  126. 10.1016/j.zemedi.2010.02.004 · DOI
  127. 10.1002/nbm.926 · DOI
  128. Chen W, 2012, Improved siderotic nodule detection in cirrhosis with susceptibility‐weighted magnetic resonance imaging: a prospective study, PLoS One, 7
  129. 10.1148/radiol.13122440 · DOI
  130. 10.1002/mrm.24848 · DOI
  131. 10.1002/mrm.25448 · DOI
  132. 10.1371/journal.pone.0053237 · DOI
  133. 10.1002/jmri.21259 · DOI
  134. 10.1016/j.urology.2010.12.056 · doi:10.1016/j.urology.2010.12.056
  135. 10.1007/BF00588364 · doi:10.1007/bf00588364
  136. 10.1007/BF02033355 · doi:10.1007/bf02033355
  137. 10.1118/1.3250860 · DOI
  138. 10.1148/radiology.164.3.3615885 · doi:10.1148/radiology.164.3.3615885
  139. 10.1148/radiol.2433060583 · DOI · Paper page
  140. 10.1097/00007632-200001150-00013 · DOI
  141. 10.1097/01.brs.0000231761.73859.2c · DOI · Paper page
  142. 10.1172/JCI118884 · DOI · Paper page
  143. 10.1097/00007632-199712150-00001 · DOI · Paper page
  144. Adams MA, 1986, The stages of disc degeneration as revealed by discograms, J. Bone Joint Surg. Br., 68, 36, 10.1302/0301-620X.68B1.3941139 · doi:10.1302/0301-620x.68b1.3941139
  145. 10.1097/00007632-198704000-00016 · DOI · Paper page
  146. 10.1148/radiology.170.2.2911680 · doi:10.1148/radiology.170.2.2911680
  147. 10.1097/BRS.0b013e31815a59a0 · DOI · Paper page
  148. 10.1002/(SICI)1522-2594(199905)41:5<992::AID-MRM19>3.0.CO;2-Y · DOI
  149. 10.1002/nbm.1106 · doi:10.1002/nbm.1106
  150. 10.3174/ajnr.A0546 · DOI
  151. 10.1148/radiol.13120874 · doi:10.1148/radiol.13120874
  152. 10.1002/jmri.21989 · DOI
  153. 10.1016/j.neuroimage.2014.06.011 · DOI
  154. 10.1002/mrm.25316 · DOI
  155. 10.1016/j.neuroimage.2010.01.108 · DOI · Paper page
  156. 10.1016/j.neuroimage.2011.03.046 · DOI
  157. 10.1177/1352458514525868 · DOI · Paper page
  158. 10.1016/j.neuroimage.2015.02.041 · DOI · Paper page
  159. 10.1016/j.mri.2008.04.008 · DOI
  160. 10.1002/mrm.25347 · DOI · Paper page
  161. 10.1016/j.neuroimage.2015.08.015 · DOI
  162. ChenW JinZ LiuF DuYP.Application of SVD‐based sparsity in compressed sensing susceptibility weighted imaging.5th International Conference on Biomedical Engineering and Informatics(BMEI) Chongqing China 2012;447–450. · doi:10.1109/bmei.2012.6513159
  163. JinZ XiangQ‐S DuYP.Acceleration of susceptibility weighted imaging using compressed sensing.5th International Conference on Biomedical Engineering and Informatics(BMEI) Chongqing China 2012;22–25. · doi:10.1109/bmei.2012.6512887
  164. NakarmiU PrasadS YingL PolakP ZivadinovR SchweserF.Compressed Sensing (CS) in phase imaging requires dedicated reconstruction strategies.Proceedings of the 23rd Annual Meeting ISMRM Toronto ON Canada 2015;3329.
  165. 10.1002/jmri.24245 · DOI
  166. 10.1002/jmri.24476 · DOI
  167. 10.1016/j.crad.2014.06.010 · DOI

Cited by

See all 170

Metadata

Authors
Liu, S., Buch, S., Chen, Y., Choi, H., Dai, Y., Habib, C., Hu, J., Jung, J., Luo, Y., Utriainen, D., Wang, M., Wu, D., Xia, S., & Haacke, E. M.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2016-05-18
Volume
30
Issue
4
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2398539186
Cited by
170
References
14
FWCI
14.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.