CoChat

ELISA in the multiplex era: Potentials and pitfalls

Open access
Tighe, Patrick J., Ryder, Richard R., Todd, Ian, Fairclough, Lucy C. · 2015 · PROTEOMICS – Clinical Applications

The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.

Abstract

Multiplex immunoassays confer several advantages over widely adopted singleplex immunoassays including increased efficiency at a reduced expense, greater output per sample volume ratios and higher throughput predicating more resolute, detailed diagnostics and facilitating personalised medicine. Nonetheless, to date, relatively few protein multiplex immunoassays have been validated for in vitro diagnostics in clinical/point‐of‐care settings. This review article will outline the challenges, which must be ameliorated prior to the widespread integration of multiplex immunoassays in clinical settings: (i) biomarker validation; (ii) standardisation of immunoassay design and quality control (calibration and quantification); (iii) availability, stability, specificity and cross‐reactivity of reagents; (iv) assay automation and the use of validated algorithms for transformation of raw data into diagnostic results. A compendium of multiplex immunoassays applicable to in vitro diagnostics and a summary of the diagnostic products currently available commercially are included, along with an analysis of the relative states of development for each format (namely planar slide based, suspension and planar/microtitre plate based) with respect to the aforementioned issues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/prca.201400130

Cites

92 of 92 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Timelines charting the theoretical and practical milestones in the development of multiplex technology for suspension and planar immunoassay formats. The first commercial suspension array was available before the first planar‐based array 94, 95, 96.
Figure 1 Timelines charting the theoretical and practical milestones in the development of multiplex technology for suspension and planar immunoassay formats. The first commercial suspension array was available before the first planar‐based array 94, 95, 96.CC BY-NC-ND · PubMed Central
Figure 2 Number of publications published per year, as found within the PubMed database (sampling 1996–2013) using the following keywords search parameters. Multiplex ELISA, multiplex immunoassay, multiplex array, microarray immunoassay, ‘or’ set of searches is derived from accumulating the search terms above using a logical or to combine: (((((multiplex immunoassay) or multiplex ELISA) or multiplex bead) or multiplex cytokine) or multiplex array) or bead immunoassay multiplex+ = ((bead) or (cytokine) or (ELISA) or (array) or (protein) or (antibody) or (antigen) and immunoassay) and multiplex. Numbers were obtained by the PubMed build‐in year count facility, by downloads of CSV files for each search performed, after reviewing the returned papers. The year 2013 was chosen as a cutoff as current year PubMed papers are still increasing each month at the time of writing.
Figure 2 Number of publications published per year, as found within the PubMed database (sampling 1996–2013) using the following keywords search parameters. Multiplex ELISA, multiplex immunoassay, multiplex array, microarray immunoassay, ‘or’ set of searches is derived from accumulating the search terms above using a logical or to combine: (((((multiplex immunoassay) or multiplex ELISA) or multiplex bead) or multiplex cytokine) or multiplex array) or bead immunoassay multiplex+ = ((bead) or (cytokine) or (ELISA) or (array) or (protein) or (antibody) or (antigen) and immunoassay) and multiplex. Numbers were obtained by the PubMed build‐in year count facility, by downloads of CSV files for each search performed, after reviewing the returned papers. The year 2013 was chosen as a cutoff as current year PubMed papers are still increasing each month at the time of writing.CC BY-NC-ND · PubMed Central
Figure 3 Multiplex formats in common use include planar‐based assays or suspension‐based assays. (A) Planar arrays can be produced in two formats, either slide based or microtitre based. A common starting point for such assays, as with ELISA, would be a serum sample extracted from blood (i). Unlike microtitre plate based formats, slide‐based formats support numerous layouts whereby repeated or individual assays composed of specific sets of antibodies are printed robotically upon the activated slide surface (ii). The sample matrix is applied and discrete assays are spatially separated by a frame and gasket, whereby they may be subsequently treated as individual microtitre wells, subject to blocking, washing, etc. Internal standards and replicates may be included also (C). Detection results from application of a composite of specific secondary antibodies coupled to a chemiluminescent/fluorescent reporter systems (iv). Microtitre‐based immunoassays harbour regularly printed antibody sets within the confines of the wells of a standard (SBS format) protein‐binding plate (v). The plate may thus be treated akin to a conventional ELISA (i.e. blocking, incubation and washing followed by detection with a set of reporter‐conjugated detection antibodies). (B) Suspension immunoassays also have a common starting point – serum sample extracted from blood (i). This assay employs thousands of micrometre‐sized plastic microbeads infused with a single (or several) chemiluminescent/fluorescent dyes and a functionally activated surface, prior to linking with a specific capture antibody. Numerous sets of such beads are prepared, each maintaining separate capture antibodies according to the cognate analyte and a unique fluorescent signature enabling identification (ii). The sample and a cocktail of all the requisite bead sets are thereafter combined. Sets of detection antibodies, all of which are individually labelled with a single chemiluminescent/fluorescent reporter (separate from those contained within the beads) are added upon completion of incubation and washing stages (iii). Each bead thus accommodates a ‘sandwich’ consisting of the captured target analyte and the cognate reporter‐conjugated detection antibody (iv). Post‐additional washing stages, bead analyte reporter constructs are subject to analysis in a flow chamber implementing individual bead separation, whereby lasers excite the chemiluminescent/fluorescent reporters and emitted light is collected by a series of detectors for quantitative analysis (v).
Figure 3 Multiplex formats in common use include planar‐based assays or suspension‐based assays. (A) Planar arrays can be produced in two formats, either slide based or microtitre based. A common starting point for such assays, as with ELISA, would be a serum sample extracted from blood (i). Unlike microtitre plate based formats, slide‐based formats support numerous layouts whereby repeated or individual assays composed of specific sets of antibodies are printed robotically upon the activated slide surface (ii). The sample matrix is applied and discrete assays are spatially separated by a frame and gasket, whereby they may be subsequently treated as individual microtitre wells, subject to blocking, washing, etc. Internal standards and replicates may be included also (C). Detection results from application of a composite of specific secondary antibodies coupled to a chemiluminescent/fluorescent reporter systems (iv). Microtitre‐based immunoassays harbour regularly printed antibody sets within the confines of the wells of a standard (SBS format) protein‐binding plate (v). The plate may thus be treated akin to a conventional ELISA (i.e. blocking, incubation and washing followed by detection with a set of reporter‐conjugated detection antibodies). (B) Suspension immunoassays also have a common starting point – serum sample extracted from blood (i). This assay employs thousands of micrometre‐sized plastic microbeads infused with a single (or several) chemiluminescent/fluorescent dyes and a functionally activated surface, prior to linking with a specific capture antibody. Numerous sets of such beads are prepared, each maintaining separate capture antibodies according to the cognate analyte and a unique fluorescent signature enabling identification (ii). The sample and a cocktail of all the requisite bead sets are thereafter combined. Sets of detection antibodies, all of which are individually labelled with a single chemiluminescent/fluorescent reporter (separate from those contained within the beads) are added upon completion of incubation and washing stages (iii). Each bead thus accommodates a ‘sandwich’ consisting of the captured target analyte and the cognate reporter‐conjugated detection antibody (iv). Post‐additional washing stages, bead analyte reporter constructs are subject to analysis in a flow chamber implementing individual bead separation, whereby lasers excite the chemiluminescent/fluorescent reporters and emitted light is collected by a series of detectors for quantitative analysis (v).CC BY-NC-ND · PubMed Central
Figure 4 Radar plots depicting the developmental stage of components related to multiplexed assay systems. Each segment represents one of the cardinal, inter‐related requirements associated with validation of multiplex immunoassays for routine diagnostic application. (A) Planar, microtitre plate based immunoassays; (B) glass slide based immunoassays and (C) suspension bead based immunoassays. Accordingly, progress/research towards resolution of a particular aspect results in the corresponding segment filling outwards from the centre, where maximum segment coverage represents a satisfactory standard for routine application in point‐of‐care/diagnostic settings. A complete fill for all segments would represent an exacting qualification of an immunoassay format for unanimous integration into routine point‐of‐care/diagnostic settings.
Figure 4 Radar plots depicting the developmental stage of components related to multiplexed assay systems. Each segment represents one of the cardinal, inter‐related requirements associated with validation of multiplex immunoassays for routine diagnostic application. (A) Planar, microtitre plate based immunoassays; (B) glass slide based immunoassays and (C) suspension bead based immunoassays. Accordingly, progress/research towards resolution of a particular aspect results in the corresponding segment filling outwards from the centre, where maximum segment coverage represents a satisfactory standard for routine application in point‐of‐care/diagnostic settings. A complete fill for all segments would represent an exacting qualification of an immunoassay format for unanimous integration into routine point‐of‐care/diagnostic settings.CC BY-NC-ND · PubMed Central
Figure 5 Pie chart representing relative prevalence of validated commercially available multiplex assays according to clinical application. Please note that most of these assays are currently validated for research use only, implying that they have not been validated to specific FDA or other national/international clinical standards. The largest numbers of commercially available assays are for autoimmunity and allergy and cytokines/chemokines.
Figure 5 Pie chart representing relative prevalence of validated commercially available multiplex assays according to clinical application. Please note that most of these assays are currently validated for research use only, implying that they have not been validated to specific FDA or other national/international clinical standards. The largest numbers of commercially available assays are for autoimmunity and allergy and cytokines/chemokines.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 92 references

Research works printed but not linked: 1

  1. Guo, A., Zhu, X.‐Y., in: Predki P. (Ed.), Functional Protein Microarrays: Pathways to Discovery, CRC Press, Boca Raton, FL 2006, pp. 60– 61.

Cited by

Items 301–400 of 539

Metadata

Authors
Tighe, P. J., Ryder, R. R., Todd, I., & Fairclough, L. C.
Affiliations
University of Nottingham (GB)
Corresponding author
Fairclough, Lucy C.
Venue
PROTEOMICS – Clinical Applications
Publisher
Wiley
Published
2015-03-25
Volume
9
Issue
3-4
Pages
406-422
ISSN
  • 1862-8346 (ISSN-L)
  • 1862-8354
OpenAlex
W2136663003
Cited by
464
References
92
Citations by year
2026: 58 · 2025: 39 · 2024: 51 · 2023: 35 · 2022: 36 · 2021: 40 · 2020: 48 · 2019: 36 · 2018: 47 · 2017: 35 · 2016: 27 · 2015: 11
FWCI
3.88
Type
journal article
Language
en
Open access
Locations
  • PROTEOMICS - CLINICAL APPLICATIONS (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by-nc-nd)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by-nc-nd)
  • Nottingham ePrints (University of Nottingham) (submittedVersion, cc-by-nc-nd)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
multiplex immunoassay, ELISA, in vitro diagnostics, biomarker validation, quality control, reagent specificity, cross-reactivity, assay automation, point-of-care testing, personalized medicine
MeSH terms
Enzyme-Linked Immunosorbent Assay, Humans, Immunoassay, Biomarkers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.