The determination of protein, oligonucleotide and peptide molecular weights by ion‐spray mass spectrometry
Abstract
The mass spectra of several compounds with molecular weights in the 2500–20 000 Da range were obtained with a quadrupole mass spectrometer equipped with an atmospheric pressure ion source. Average molecular weight determinations of mellitin (2846.4 Da), a synthetic oligonucleotide (4262.8 Da), myoglobin (16 950.4 Da) and on the subunits of β‐lactoglobulin (18 277.1 Da) requiring as little as 1 pmol of material were achieved with accuracies and precisions of ± 1 Da. An ion‐spray interface was used to produce ions via the ion evaporation process, producing mass spectra containing a series of multiply‐charged molecular species. A simple method for calculating the molecular weight of unknown compounds from the spectra containing multiply‐charged ions is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atlas of Protein Sequence and Structure, 1972.
Fitch, W. M., & Dayhoff, M. O. (1973) · Systematic Zoology · doi:10.2307/2412105 · Cited by 2,436
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
Self-citationField induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Multiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Isotopic distributions in mass spectra of large molecules
Yergey, J., Heller, D., Hansen, G., Cotter, R. J., & Fenselau, C. (1983) · Analytical Chemistry · doi:10.1021/ac00253a037 · Cited by 201
Thomson, B. A., Iribarne, J. V., & Dziedzic, P. J. (1982) · Analytical Chemistry · doi:10.1021/ac00250a020 · Cited by 146
Atmospheric pressure ion evaporation-mass spectrometry
Iribarne, J. V., Dziedzic, P. J., & Thomson, B. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)87009-0 · Cited by 136
Barber, M., Green, B. N., & Jennings, K. R. (1987) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290010505 · Cited by 127
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Tandem Mass Spectrometry of Small, Multiply Charged Oligonucleotides
Mcluckey, S. A., Van Berkel, G. J., & Glish, G. L. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85019-g · Cited by 551
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Zhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Katta, V., Chait, B. T., & Carr, S. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050415 · Cited by 453
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Self-citationLoo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Weighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Mass spectrometric approaches for the identification of gel‐separated proteins
Patterson, S. D., & Aebersold, R. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601299 · Cited by 378
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Mechanism of electrospray mass spectrometry. Electrospray as an electrolysis cell
Blades, A. T., Ikonomou, M. G., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00019a009 · Cited by 364
Large-Scale and Automated DNA Sequence Determination
Hunkapiller, T., Kaiser, R. J., Koop, B. F., & Hood, L. (1991) · Science · doi:10.1126/science.1925562 · Cited by 361
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Budiša, N., Steipe, B., Demange, P., Eckerskorn, C., Kellermann, J., & Huber, R. (1995) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1995.0788h.x · Cited by 340
Carbohydrate Molecular Weight Profiling, Sequence, Linkage, and Branching Data: ES-MS and CID
Reinhold, V. N., Reinhold, B. B., & Costello, C. E. (1995) · Analytical Chemistry · doi:10.1021/ac00107a005 · Cited by 336
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 322
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Mass spectrometry of nucleic acids
Nordhoff, E., Kirpekar, F., & Roepstorff, P. (1996) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1996)15:2<67::aid-mas1>3.0.co;2-8 · Cited by 315
Beavis, R. C., & Chait, B. T. (1990) · Analytical Chemistry · doi:10.1021/ac00216a020 · Cited by 314
Rapid, sensitive analysis of protein mixtures by mass spectrometry.
Beavis, R. C., & Chait, B. T. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.17.6873 · Cited by 301
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1990) · Science · doi:10.1126/science.2326633 · Cited by 300
Investigations of the electrospray interface for liquid chromatography/mass spectrometry
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1990) · Analytical Chemistry · doi:10.1021/ac00208a012 · Cited by 293
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Protein identification in the post-genome era: the rapid rise of proteomics
JAMES, P. (1997) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583597003399 · Cited by 285
Carr, S. A., Huddleston, M. J., & Bean, M. F. (1993) · Protein Science · doi:10.1002/pro.5560020207 · Cited by 284
Identification of Two Functionally Different Classes of Exocellulases
Barr, B. K., Hsieh, Y.-L., Ganem, B., & Wilson, D. B. (1996) · Biochemistry · doi:10.1021/bi9520388 · Cited by 281
Baudier, J., Deloulme, J. C., Van Dorsselaer, A., Black, D., & Matthes, H. W. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)52425-x · Cited by 274
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Self-citationTang, L., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00023a009 · Cited by 260
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Barclay, V. J., Bonner, R. F., & Hamilton, I. P. (1997) · Analytical Chemistry · doi:10.1021/ac960638m · Cited by 253
Self-citationCollision cross sections for protein ions
Covey, T., & Douglas, D. J. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85025-s · Cited by 253
Self-citationSPARC is a source of copper-binding peptides that stimulate angiogenesis
Lane, T. F., Iruela-Arispe, M. L., Johnson, R. S., & Sage, E. H. (1994) · The Journal of cell biology · doi:10.1083/jcb.125.4.929 · Cited by 249
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Surfactant effects on protein structure examined by electrospray ionization mass spectrometry
Loo, R. R. O., Dales, N., & Andrews, P. C. (1994) · Protein Science · doi:10.1002/pro.5560031109 · Cited by 184
Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
Intact-Mass Analysis Facilitating the Identification of Large Human Heart Proteoforms
Schaffer, L. V., Tucholski, T., Shortreed, M. R., Ge, Y., & Smith, L. M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02343 · Cited by 17
Ion-ion proton transfer reactions of multiply-charged oligonucleotide cations
Stephenson, J. L., & McLuckey, S. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00176-6 · Cited by 11
Metadata
- Authors
- Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1988-11
- Volume
- 2
- Issue
- 11
- Pages
- 249-256
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1973486893
- Cited by
- 593
- References
- 10
- FWCI
- 32.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.