CoChat

A modified procedure for gas‐source isotope ratio mass spectrometry: the long‐integration dual‐inlet (LIDI) methodology and implications for clumped isotope measurements

Hu, Bin, Radke, Jens, Schlüter, Hans‐Jürgen, Heine, Frank Torsten, Zhou, Liping, Bernasconi, Stefano M. · 2014 · Rapid Communications in Mass Spectrometry
Cited by 91

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

RATIONALE: High‐precision stable isotope measurements in gas‐source isotope ratio mass spectrometry are generally carried out by repeated comparison of the composition of an unknown sample with that of a working gas (WG) through a dual‐inlet (DI). Due to the established DI protocols, however, most of the sample gas is wasted rather than measured, which is a major problem when sample size is limited. Here we propose a new methodology allowing the measurement of a much larger portion of the available sample. METHODS: We tested a new measurement protocol, the long‐integration dual‐inlet (LIDI) method, which consists of a single measurement of the sample for 200 to 600 seconds followed by a single measurement of the WG. The isotope ratios of the sample are calculated by comparison of the beam ratios of the WG and sample at equivalent intensities of the major ion beam. RESULTS: Three isotopically very different CO 2 samples were analyzed. The LIDI measurements of large samples (50 to 100 µmol of CO 2 ) measured at quasi‐constant beam sizes, and of small samples (1.5 to 2 µmol of CO 2 ) measured in micro‐volume mode, generated results that are indistinguishable from the standard DI measurements for carbon, oxygen and clumped isotope compositions. The external precision of Δ 47 using the LIDI protocol (~±0.007 ‰) is similar to that of the state of the art DI measurements. CONCLUSIONS: For traditional and clumped isotope measurements of CO 2 , the LIDI protocol allows the measurement of a much larger portion of the sample gas rather than only ~20 % of it. In addition, the sample can be measured at higher signal intensity and for longer time, allowing the measurement of smaller samples while preserving precision. We suggest that other gases commonly used for stable isotope measurements with gas‐source mass spectrometry would also benefit from this new protocol. Copyright © 2014 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.6909

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Research works printed but not linked: 16

  1. 10.1063/1.1740961 · DOI · Paper page
  2. 10.1063/1.1745698 · DOI · Paper page
  3. 10.1002/(SICI)1096-9888(199603)31:3<225::AID-JMS319>3.0.CO;2-L · DOI · Paper page
  4. 10.1016/0146-6380(90)90147-R · DOI · Paper page
  5. 10.1016/B978-044451114-0/50040-5 · DOI
  6. 10.1029/95PA03773 · DOI
  7. 10.1002/rcm.6400 · DOI · Paper page
  8. 10.1016/j.epsl.2012.05.013 · DOI
  9. 10.1073/pnas.1109444108 · DOI · Paper page
  10. 10.1016/j.ijms.2012.10.014 · DOI
  11. 10.1029/2012JD017992 · DOI · Paper page
  12. 10.1016/j.gca.2005.08.021 · DOI · Paper page
  13. 10.1002/rcm.905 · DOI
  14. 10.1002/rcm.906 · DOI · Paper page
  15. 10.1063/1.1745483 · DOI
  16. 10.1002/rcm.6436 · DOI · Paper page

Cited by

Metadata

Authors
Hu, B., Radke, J., Schlüter, H., Heine, F. T., Zhou, L., & Bernasconi, S. M.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2014-05-22
Volume
28
Issue
13
Pages
1413-1425
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2147109978
Cited by
91
References
15
FWCI
1.90
Type
journal article
Language
en
Open access
closed
Funders
  • National Natural Science Foundation of China (41073008)
  • Sino Swiss Science and Technology Cooperation (EG 03-032010)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.