CoChat

Determination of perfluorooctane sulfonate in river water by liquid chromatography/atmospheric pressure photoionization mass spectrometry by automated on‐line extraction using turbulent flow chromatography

Takino, Masahiko, Daishima, Shigeki, Nakahara, Taketoshi · 2003 · Rapid Communications in Mass Spectrometry
Cited by 120

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A simple, fast and sensitive liquid chromatography/atmospheric pressure photoionization mass spectrometry (LC/APPI‐MS) method, with automated on‐line extraction using turbulent flow chromatography (TFC), was developed for the determination of perfluorooctane sulfonate (PFOS) in river water. In this method, following an on‐line extraction by injection onto a column under TFC conditions, PFOS is back‐flushed onto a reversed‐phase column via on‐line column switching, and resolved chromatographically at a laminar flow rate of 1 mL min −1 . Using this tandem LC‐LC/APPI‐MS system the extraction, separation and selective detection of PFOS in river water could be achieved with satisfactory selectivity and sensitivity. The limit of detection (LOD) (S/N = 3) and the limit of quantitation (LOQ) (S/N = 10)were 5.35 and 17.86 pg mL −1 . The described procedure was very simple since no off‐line sample preparation was required, total analysis time being 18.75 min. Copyright © 2003 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.937

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Takino, M., Daishima, S., & Nakahara, T.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2003-01-20
Volume
17
Issue
5
Pages
383-390
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2014648193
Cited by
120
References
4
FWCI
7.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.