The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Magnetic resonance relaxation properties of superparamagnetic particles
Abstract
Nanometric crystals of maghemite are known to exhibit superparamagnetism. Because of the significance of their magnetic moment, maghemite nanoparticles are exceptional contrast agents and are used for magnetic resonance imaging (of the liver, spleen, lymph nodes), for magnetic resonance angiography and for molecular and cellular imaging. The relaxivity of these agents depends on their size, saturation magnetization and magnetic field and also on their degree of clustering. There are different types of maghemite particles whose relaxation characteristics are suited to a specific MRI application. The relaxation induced by maghemite particles is caused by the diffusion of water protons in the inhomogeneous field surrounding the particles. This is well described by a theoretical model that takes magnetite crystal anisotropy and Néel relaxation into account. Another type of superparamagnetic compound is ferritin, the iron‐storing protein: it contains a superparamagnetic ferrihydrite core. Even if the resulting magnetic moment of ferritin is far smaller than for magnetite nanoparticles, its massive presence in different organs darkens T2‐weighted MR images, allowing the noninvasive estimation of iron content, thanks to MRI. The relaxation induced by ferritin in aqueous solutions has been demonstrated to be caused by the exchange of protons between bulk water protons and the surface of the ferrihydrite crystal. However, in vivo, the relaxation properties of ferritin are still unexplained, probably because of protein clustering. Copyright © 2009 John Wiley & Sons, Inc. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Iron Oxides: Structure, Properties, Reactions, Occurences and Uses
Cornell, R. M., & Schwertmann, U. (2003) · doi:10.1002/3527602097 · Cited by 4,422
The ferritins: molecular properties, iron storage function and cellular regulation
Harrison, P. M., & Arosio, P. (1996) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(96)00022-9 · Cited by 2,667
Artificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
(2013) · Wiley eBooks · doi:10.1002/9781118503652 · Cited by 1,468
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
The Structure of Ferrihydrite, a Nanocrystalline Material
Michel, F. M., Ehm, L., Antao, S. M., Lee, P. L., Chupas, P. J., Liu, G., Strongin, D. R., Schoonen, M. A. A., Phillips, B. L., & Parise, J. B. (2007) · Science · doi:10.1126/science.1142525 · Cited by 901
Jung, C. W., & Jacobs, P. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00024-b · Cited by 622
Hwang, L.-P., & Freed, J. H. (1975) · The Journal of Chemical Physics · doi:10.1063/1.431841 · Cited by 600
Non-invasive detection of apoptosis using magnetic resonance imaging and a targeted contrast agent
Zhao, M., Beauregard, D. A., Loizou, L., Davletov, B., & Brindle, K. M. (2001) · Nature Medicine · doi:10.1038/nm1101-1241 · Cited by 521
Freed, J. H. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436302 · Cited by 442
Theory of proton relaxation induced by superparamagnetic particles
Roch, A., Muller, R. N., & Gillis, P. (1999) · The Journal of Chemical Physics · doi:10.1063/1.478435 · Cited by 428
Self-citationGillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Self-citationTheory of 1/T1 and 1/T2 NMRD profiles of solutions of magnetic nanoparticles
Koenig, S. H., & Kellar, K. E. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340214 · Cited by 314
Detection of Alzheimer's amyloid in transgenic mice using magnetic resonance microimaging
Wadghiri, Y. Z., Sigurdsson, E. M., Sadowski, M., Elliott, J. I., Li, Y., Scholtzova, H., Tang, C. Y., Aguinaldo, G., Pappolla, M., Duff, K., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10529 · Cited by 280
Ros, P. R., Freeny, P. C., Harms, S. E., Seltzer, S. E., Davis, P. L., Chan, T. W., Stillman, A. E., Muroff, L. R., Runge, V. M., & Nissenbaum, M. A. (1995) · Radiology · doi:10.1148/radiology.196.2.7617864 · Cited by 278
Noninvasive measurement of iron: report of an NIDDK workshop
Brittenham, G. M., & Badman, D. G. (2003) · Blood · doi:10.1182/blood-2002-06-1723 · Cited by 274
Superparamagnetic colloid suspensions: Water magnetic relaxation and clustering
Roch, A., Gossuin, Y., Muller, R. N., & Gillis, P. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.070 · Cited by 272
Self-citationWan, J., Cai, W., Meng, X., & Liu, E. (2007) · Chemical Communications · doi:10.1039/b712795b · Cited by 266
On T2‐shortening by weakly magnetized particles: The chemical exchange model†
Brooks, R. A., Moiny, F., & Gillis, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1135 · Cited by 228
Self-citationApplication of the static dephasing regime theory to superparamagnetic iron‐oxide loaded cells
Bowen, C. V., Zhang, X., Saab, G., Gareau, P. J., & Rutt, B. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10192 · Cited by 226
Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Sato, Y., Yuh, W. T., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B. (1994) · Radiology · doi:10.1148/radiology.192.3.7520182 · Cited by 220
Le phénomène de superparamagnétisme
Dormann, J. L. (1981) · Revue de Physique Appliquée · doi:10.1051/rphysap:01981001606027500 · Cited by 186
Ferritin: a model superparamagnet
Kilcoyne, S. H., & Cywinski, R. (1995) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(94)00626-1 · Cited by 181
Bjørnerud, A., & Johansson, L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.904 · Cited by 173
T1 and T2 relaxivity of intracellular and extracellular USPIO at 1.5T and 3T clinical MR scanning
Simon, G. H., Bauer, J., Saborovski, O., Fu, Y., Corot, C., Wendland, M. F., & Daldrup-Link, H. E. (2006) · European Radiology · doi:10.1007/s00330-005-0031-2 · Cited by 172
The relation between brain iron and NMR relaxation times: An in vitro study
Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350108 · Cited by 172
Magnetoferritin: Characterization of a novel superparamagnetic MR contrast agent
Bulte, J. W. M., Douglas, T., Mann, S., Frankel, R. B., Moskowitz, B. M., Brooks, R. A., Baumgarner, C. D., Vymazal, J., Strub, M., & Frank, J. A. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040343 · Cited by 162
Cellular Imaging of Inflammation in Atherosclerosis Using Magnetofluorescent Nanomaterials
Jaffer, F. A., Nahrendorf, M., Sosnovik, D. E., Kelly, K. A., Aïkawa, E., & Weissleder, R. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00009 · Cited by 150
Kellar, K. E., Fujii, D. K., Gunther, W. H. H., Briley-S�b�, K., Bj�rnerud, A., Spiller, M., & Koenig, S. H. (2000) · Journal of Magnetic Resonance Imaging · Cited by 138
Li, H., Xu, Y., Qi, X., Maitani, Y., & Nagai, T. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.11.036 · Cited by 131
Relaxation induced by ferritin: a better understanding for an improved MRI iron quantification
Gossuin, Y., Müller, R. N., & Gillis, P. (2004) · NMR in Biomedicine · doi:10.1002/nbm.903 · Cited by 117
Self-citationBrown, R. J. S. (1961) · Physical Review · doi:10.1103/physrev.121.1379 · Cited by 114
Frequency dependence of MR relaxation times II. Iron oxides
Bulte, J. W. M., Vymazal, J., Brooks, R. A., Pierpaoli, C. M., & Frank, J. A. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030414 · Cited by 113
T1 and t2 of ferritin at different field strengths: effect on mri
Vymazal, J., Brooks, R. A., Zak, O., McRill, C., Shen, C., & Chiro, G. D. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270218 · Cited by 110
Gembris, D., Taylor, J. G., Schor, S., Frings, W., Suter, D., & Posse, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<237::aid-mrm10>3.0.co;2-5 · Cited by 108
Preparation, relaxometry, and biokinetics of PEGylated magnetoliposomes as MR contrast agent
Bulte, J. W. M., Cuyper, M. D., Despres, D., & Frank, J. A. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00556-3 · Cited by 100
Quantification of superparamagnetic iron oxide (SPIO)‐labeled cells using MRI
Rad, A. M., Arbab, A. S., Iskander, A., Jiang, Q., & Hamid Soltanian-zadeh, A. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20978 · Cited by 96
Larsen, B. A., Haag, M. A., Serkova, N. J., Shroyer, K. R., & Stoldt, C. R. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/26/265102 · Cited by 95
T1 and T2 of ferritin solutions: Effect of loading factor
Vymazal, J., Zak, O., Bulte, J. W. M., Aisen, P., & Brooks, R. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360111 · Cited by 84
Papakonstantinou, O., Maris, T. G., Kostaridou, V., Gouliamos, A. D., Koutoulas, G. K., Kalovidouris, A. E., Papavassiliou, G. B., Kordas, G. C., Kattamis, C., Vlahos, L. J., et al. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00041-e · Cited by 82
RELAXATION BY METAL-CONTAINING NANOSYSTEMS
Müller, R. N., Elst, L. V., Roch, A., Peters, J. A., Csajbók, É., Gillis, P., & Gossuin, Y. (2005) · Advances in inorganic chemistry · doi:10.1016/s0898-8838(05)57005-3 · Cited by 57
Self-citationGossuin, Y., Roch, A., Müller, R. N., Gillis, P., & Bue, F. L. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10316 · Cited by 55
Self-citationKehagias, D. T., Gouliamos, A. D., Smyrniotis, V. E., & Vlahos, L. J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1224 · Cited by 54
Relaxation by clustered ferritin: a model for ferritin‐induced relaxation in vivo
Gossuin, Y., Gillis, P., Müller, R. N., & Hocq, A. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1140 · Cited by 38
Self-citationGossuin, Y., Roch, A., Bue, F. L., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1216 · Cited by 31
Self-citationKellar, K. E., Fujii, D. K., Gunther, W. H. H., Briley-Saebo, K. C., Bjornerod, A., Spiller, M., & Koenig, S. H. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80391-4 · Cited by 17
Imaging macrophage activity in the brain by using ultrasmall particles of iron oxide.
Bulte, J. W. M., & Frank, J. A. (2000) · PubMed Central · Cited by 16
Use of intravascular contrast agents in MRI
Bjørnerud, A., Wendland, M. F., Johansson, L., Ahlstrom, H. K., Higgins, C. B., & Øksendal, A. N. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80111-6 · Cited by 15
Three Types of Physical Measurements Needed to Characterize Iron Oxide Nanoparticles for MRI and MRA
Koenig, S. H., Kellar, K. E., Fujii, D. K., Gunther, W. H. H., Briley-Saebo, K. C., & Spiller, M. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80386-0 · Cited by 13
Kreft, B. P., Tanimoto, A., Leffler, S., Finn, J. P., Øksendal, A. N., & Stark, D. D. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040324 · Cited by 13
Cited by
Engineering Multifunctional Capsules through the Assembly of Metal–Phenolic Networks
Guo, J., Ping, Y., Ejima, H., Alt, K., Meissner, M., Richardson, J. J., Yan, Y., Peter, K., von Elverfeldt, D., Hagemeyer, C. E., et al. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201311136 · Cited by 1,157
Iron Oxide Based Nanoparticles for Multimodal Imaging and Magnetoresponsive Therapy
Lee, N., Yoo, D., Ling, D., Cho, M. H., Hyeon, T., & Cheon, J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00112 · Cited by 1,005
Nguyen, M. D., Tran, H.-V., Xu, S., & Lee, T. R. (2021) · Applied Sciences · doi:10.3390/app112311301 · Cited by 783
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Magnetite nanoparticles for cancer diagnosis, treatment, and treatment monitoring: recent advances
Revia, R. A., & Zhang, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.08.022 · Cited by 612
Metadata
- Authors
- Gossuin, Y., Gillis, P., Hocq, A., Vuong, Q. L., & Roch, A.
- Venue
- WIREs Nanomedicine and Nanobiotechnology
- Publisher
- Wiley
- Published
- 2009-03-11
- Volume
- 1
- Issue
- 3
- Pages
- 299-310
- ISSN
- 1939-0041 (ISSN-L)
- 1939-5116
- OpenAlex
- W2040367363
- Cited by
- 319
- References
- 53
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.