The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Pulse oximetry: Analysis of theory, technology, and practice
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
YELDERMAN, M., & NEW, W. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00015 · Cited by 486
Effects of Methemoglobinemia on Pulse Oximetry and Mixed Venous Oximetry
Barker, S. J., Tremper, K. K., & Hyatt, J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00021 · Cited by 382
Accuracy of Response of Six Pulse Oximeters to Profound Hypoxia
Severinghaus, J. W., & Naifeh, K. H. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00017 · Cited by 312
Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
Yoshiya, I., Shimada, Y., & Tanaka, K. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442476 · Cited by 261
Effects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
History of blood gas analysis.
Jw, S., & Astrup, P. (1987) · PubMed · Cited by 187
Carboxyhemoglobin Levels in American Blood Donors
Stewart, R. D. (1974) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1974.03230470029019 · Cited by 160
The Accuracy and Response Characteristics of a Simplified Ear Oximeter
Rebuck, A. S., Chapman, K. R., & D’Urzo, A. D. (1983) · CHEST Journal · doi:10.1378/chest.83.6.860 · Cited by 126
Pulse Oximetry: Technical Aspects of Machine Design
Pologe, J. A. (1987) · International Anesthesiology Clinics · doi:10.1097/00004311-198702530-00009 · Cited by 110
Self-citationEvaluation of the Ohmeda 3700 Pulse Oximeter: Steady-state and Transient Response Characteristics
Kagle, D. M., Alexander, C. M., Berko, R. S., Gluffre, M., & Gross, J. B. (1987) · Anesthesiology · doi:10.1097/00000542-198703000-00018 · Cited by 108
Cited by
Recent Progress in Materials and Devices toward Printable and Flexible Sensors
Rim, Y. S., Bae, S., Chen, H., De Marco, N., & Yang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201505118 · Cited by 771
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
Perkins, G. D., McAuley, D. F., Giles, S., Routledge, H., & Gao, F. (2003) · Critical Care · doi:10.1186/cc2339 · Cited by 136
Moço, A., & Verkruysse, W. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00449-y · Cited by 55
The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
Baek, H. J., Shin, J., & Cho, J. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/3521738 · Cited by 22
The effect of varying LED intensity on pulse oximeter accuracy
De Kock, J. P., Reynolds, K. J., Tarassenko, L., & Moyles, J. T. B. (1991) · Journal of Medical Engineering & Technology · doi:10.3109/03091909109016208 · Cited by 16
Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry
Alkhoury, L., Choi, J.-W., Wang, C., Rajasekar, A., Acharya, S., Mahoney, S., Shender, B. S., Hrebien, L., & Kam, M. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00539-2 · Cited by 15
Nijland, R., Jongsma, H. W., Verbruggen, I. M., & Nijhuis, J. G. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf00857643 · Cited by 8
Metadata
- Authors
- Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A.
- Venue
- Journal of Clinical Monitoring
- Published
- 1988-10
- Volume
- 4
- Issue
- 4
- Pages
- 290-301
- ISSN
- 1387-1307 (ISSN-L)
- 0748-1977
- 1573-2614
- OpenAlex
- W1971958052
- Cited by
- 306
- References
- 19
- FWCI
- 12.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.