Optical probes and techniques for O2 measurement in live cells and tissue
Open accessThe DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.
Abstract
In recent years, significant progress has been achieved in the sensing and imaging of molecular oxygen (O(2)) in biological samples containing live cells and tissue. We review recent developments in the measurement of O(2) in such samples by optical means, particularly using the phosphorescence quenching technique. The main types of soluble O(2) sensors are assessed, including small molecule, supramolecular and particle-based structures used as extracellular or intracellular probes in conjunction with different detection modalities and measurement formats. For the different O(2) sensing systems, particular attention is paid to their merits and limitations, analytical performance, general convenience and applicability in specific biological applications. The latter include measurement of O(2) consumption rate, sample oxygenation, sensing of intracellular O(2), metabolic assessment of cells, and O(2) imaging of tissue, vasculature and individual cells. Altogether, this gives the potential user a comprehensive guide for the proper selection of the appropriate optical probe(s) and detection platform to suit their particular biological applications and measurement requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing mitochondrial dysfunction in cells
Brand, M. D., & Nicholls, D. G. (2011) · Biochemical Journal · doi:10.1042/bj20110162 · Cited by 2,842 · cited 3×
“For simple biological models, such as cell cultures or tissue slices, effects on cell viability, proliferation, energy production pathways and mitochondrial function are usually examined [5, 74].”
BackgroundMetabolic control through the PGC-1 family of transcription coactivators
Lin, J., Handschin, C., & Spiegelman, B. M. (2005) · Cell Metabolism · doi:10.1016/j.cmet.2005.05.004 · Cited by 2,130 · cited 2×
“via Warburg effect, hypoxia-induced expression of genes and proteins such as HIF-1a, PGC-1a [4, 6, 7]).”
BackgroundPhysical Mechanisms of Generation and Deactivation of Singlet Oxygen
Schweitzer, C., & Schmidt, R. (2003) · Chemical Reviews · doi:10.1021/cr010371d · Cited by 2,123 · cited 2×
“However, singlet oxygen can also react with nearby molecules, including the dye and sample components (lipids, proteins, nucleic acids), and thus affect the sensor, sample and measurement [30].”
BackgroundO’Connor, A. E., Gallagher, W. M., & Byrne, A. T. (2009) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2009.00585.x · Cited by 1,191
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Continuous Recording of Blood Oxygen Tensions by Polarography
Clark, L. C., Wolf, R., Granger, D., & Taylor, Z. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.6.3.189 · Cited by 886 · cited 2×
“These techniques have been used with isolated mitochondria, suspension cells, and in point measurements in vivo [8].”
MethodSemenza, G. L. (2007) · Science · doi:10.1126/science.1147949 · Cited by 703 · cited 2×
“Detailed understanding of the biological roles of O2 is of major fundamental and practical importance [1, 2].”
BackgroundPhotophysics and photochemistry of oxygen sensors based on luminescent transition-metal complexes
Carraway, E. R., Demas, J. N., DeGraff, B. A., & Bacon, J. R. (1991) · Analytical Chemistry · doi:10.1021/ac00004a007 · Cited by 638 · cited 1×
“However, many existing O2-sensitive materials show heterogeneity and a non-linear Stern–Volmer relationship [28].”
BackgroundGUPTA, B., LEVCHENKO, T., & TORCHILIN, V (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.10.007 · Cited by 632 · cited 1×
“mitochondria targeting peptide sequences [97]).”
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)45596-2 · Cited by 592
Myoglobin-facilitated oxygen diffusion: role of myoglobin in oxygen entry into muscle.
Wittenberg, J. B. (1970) · Physiological Reviews · doi:10.1152/physrev.1970.50.4.559 · Cited by 571 · cited 1×
“Initially, it was boosted by the introduction of Clark-type oxygen electrodes [8], photometric (myoglobin) [9, 10] and EPR systems [11], which have been very useful in basic bioenergetic, metabolic, cell biology and toxicological studies with rather simple, macroscopic models.”
MethodRECENT APPROACHES TO INTRACELLULAR DELIVERY OF DRUGS AND DNA AND ORGANELLE TARGETING
Torchilin, V. P. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095735 · Cited by 543 · cited 1×
“For example, photosensitisers of porphyrin origin used in photodynamic therapy of cancer show maximal photodamage when they are targeted to cell membranes or the nuclei [98, 99].”
BackgroundOxygen-dependent regulation of mitochondrial respiration by hypoxia-inducible factor 1
Semenza, G. L. (2007) · Biochemical Journal · doi:10.1042/bj20070389 · Cited by 541 · cited 3×
“via Warburg effect, hypoxia-induced expression of genes and proteins such as HIF-1a, PGC-1a [4, 6, 7]).”
BackgroundImaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
Rumsey, W., Vanderkooi, J., & Wilson, D. (1988) · Science · doi:10.1126/science.241.4873.1649 · Cited by 534
Sakadžić, S., Roussakis, E., Yaseen, M. A., Mandeville, E. T., Srinivasan, V. J., Arai, K., Ruvinskaya, S., Devor, A., Lo, E. H., Vinogradov, S. A., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1490 · Cited by 451
Ratiometric Single‐Nanoparticle Oxygen Sensors for Biological Imaging
Wu, C., Bull, B., Christensen, K., & McNeill, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805894 · Cited by 378
Targeted photodynamic therapy via receptor mediated delivery systems
Sharman, W. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.015 · Cited by 372 · cited 1×
“photofrin, chlorins, precursor 5-aminoluvulenic acid), the porphyrin dyes used in existing extracellular and intracellular oxygen probes rarely show significant phototoxic action on mammalian cells and tissue under standard (optimised) measurement conditions [38–41].”
BackgroundZhang, S., Hosaka, M., Yoshihara, T., Negishi, K., Iida, Y., Tobita, S., & Takeuchi, T. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-3948 · Cited by 349
Koo, Y.-E. L., Cao, Y., Kopelman, R., Koo, S. M., Brasuel, M., & Philbert, M. A. (2004) · Analytical Chemistry · doi:10.1021/ac035493f · Cited by 316 · cited 1×
“This has been demonstrated with several supramolecular- and nanoparticle-based probes, for which fast (6–16 h) and efficient cell loading comparable with the delivery of conventional small molecule cargo or cell transfection with genetically-encoded biosensor probes [25, 96] was achieved.”
BackgroundQuantitative Microplate-Based Respirometry with Correction for Oxygen Diffusion
Gerencser, A. A., Neilson, A., Choi, S. W., Edman, U., Yadava, N., Oh, R. J., Ferrick, D. A., Nicholls, D. G., & Brand, M. D. (2009) · Analytical Chemistry · doi:10.1021/ac900881z · Cited by 310 · cited 2×
“in the medium are used [57] (solid-state O2 sensitive coatings may also be suitable for these applications [50]).”
Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288 · cited 6×
“Phosphorescent Pt(II)- and Pd(II)-porphyrins are among the most popular in O2 sensing [24, 29, 31, 32].”
BackgroundMethodInfluentialBraun, R. D., Lanzen, J. L., Snyder, S. A., & Dewhirst, M. W. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2533 · Cited by 285 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundYadava, N., & Nicholls, D. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0212-07.2007 · Cited by 272 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], (19)F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundHypoxia, glucose metabolism and the Warburg’s effect
Bartrons, R., & Caro, J. (2007) · Journal of Bioenergetics and Biomembranes · doi:10.1007/s10863-007-9080-3 · Cited by 260 · cited 2×
“via Warburg effect, hypoxia-induced expression of genes and proteins such as HIF-1a, PGC-1a [4, 6, 7]).”
BackgroundTwo New “Protected” Oxyphors for Biological Oximetry: Properties and Application in Tumor Imaging
Esipova, T. V., Karagodov, A., Miller, J., Wilson, D. F., Busch, T. M., & Vinogradov, S. A. (2011) · Analytical Chemistry · doi:10.1021/ac2022234 · Cited by 247
Oxygen Microscopy by Two‐Photon‐Excited Phosphorescence
Finikova, O. S., Lebedev, A. Y., Aprelev, A., Troxler, T., Gao, F., Garnacho, C., Muro, S., Hochstrasser, R. M., & Vinogradov, S. A. (2008) · ChemPhysChem · doi:10.1002/cphc.200800296 · Cited by 240 · cited 1×
“A number of alternative, specialised techniques have been described recently, which are not discussed here; for example, non-radiative triplet quenching of the luminophores under high-power pulsed laser excitation [26] and photoacoustic sensing [94].”
MethodLo, L.-W., Koch, C. J., & Wilson, D. F. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0144 · Cited by 240
Determination of oxygen gradients in engineered tissue using a fluorescent sensor
Kellner, K., Liebsch, G., Klimant, I., Wolfbeis, O. S., Blunk, T., Schulz, M. B., & Göpferich, A. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10352 · Cited by 238 · cited 1×
“Solid-state sensors are usually used in O2 microsensors [12], sensor coatings [49] and integrated systems [50].”
BackgroundDendritic Phosphorescent Probes for Oxygen Imaging in Biological Systems
Lebedev, A. Y., Cheprakov, A. V., Sakadžić, S., Boas, D. A., Wilson, D. F., & Vinogradov, S. A. (2009) · ACS Applied Materials & Interfaces · doi:10.1021/am9001698 · Cited by 231 · cited 5×
“Other in vivo studies include: O2 mapping of rodent retina where the application of anaesthetics was shown to decrease venous O2 tension [54, 106]; O2 dynamics in individual frog skeletal muscle fibres showing that faster frequency of muscle stimulation leads to higher drops in pO2 in adaptive manner [116]; measuremen…”
BackgroundMethodInfluentialUltrabright Oxygen Optodes Based on Cyclometalated Iridium(III) Coumarin Complexes
Borisov, S. M., & Klimant, I. (2007) · Analytical Chemistry · doi:10.1021/ac0710836 · Cited by 210 · cited 1×
“Cyclometallated complexes of Ir(III) also show convenient spectral characteristics, high brightness and medium range lifetimes, compared to Pt-porphyrin and Ru(II) dyes [44, 45].”
BackgroundNanoparticle PEBBLE Sensors in Live Cells and In Vivo
Koo Lee, Y.-E., Smith, R., & Kopelman, R. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112823 · Cited by 189 · cited 1×
“Furthermore, surface modification, for example, altering the surface charge of the NPs or adding a special peptide coat, allows optimisation of their specificity, and penetration into or exclusion from the cell [64, 67, 69, 71, 72].”
BackgroundFoster, K. A., Galeffi, F., Gerich, F. J., Turner, D. A., & Müller, M. (2006) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2006.07.001 · Cited by 187 · cited 3×
“A well-known approach is the imaging of respiration activity of cells by ratiometric analysis of fluorescent electron donors and redox indicators NADH and FAD [73].”
BackgroundInfluentialIntracellular O2 Sensing Probe Based on Cell-Penetrating Phosphorescent Nanoparticles
Fercher, A., Borisov, S. M., Zhdanov, A. V., Klimant, I., & Papkovsky, D. B. (2011) · ACS Nano · doi:10.1021/nn200807g · Cited by 187 · cited 2×
“Furthermore, surface modification, for example, altering the surface charge of the NPs or adding a special peptide coat, allows optimisation of their specificity, and penetration into or exclusion from the cell [64, 67, 69, 71, 72].”
BackgroundMethodSelf-citationSharman, K. K., Periasamy, A., Ashworth, H., & Demas, J. N. (1999) · Analytical Chemistry · doi:10.1021/ac981050d · Cited by 186 · cited 5×
“In a simplified format called rapid lifetime determination (RLD) [80, 82], emission intensity signals (F1, F2) are collected at two different delay times (t1, t2) after the excitation pulse, from which lifetime is calculated as: s ¼ ðt2 t1Þ= lnðF1=F2Þ ð3Þ A number of commercial instruments—multi-label readers original…”
InfluentialEmerging Applications of Phosphorescent Metalloporphyrins
Papkovsky, D. B., & O’Riordan, T. C. (2005) · Journal of Fluorescence · doi:10.1007/s10895-005-2830-x · Cited by 181 · cited 6×
“Phosphorescent Pt(II)- and Pd(II)-porphyrins are among the most popular in O2 sensing [24, 29, 31, 32].”
BackgroundInfluentialSelf-citationAnalysis of mitochondrial function using phosphorescent oxygen-sensitive probes
Will, Y., Hynes, J., Ogurtsov, V. I., & Papkovsky, D. B. (2006) · Nature Protocols · doi:10.1038/nprot.2006.351 · Cited by 171 · cited 1×
“whole organisms, O2 is also a valuable parameter, for example in radio- and chemotherapy, assisted reproductive technology and organ transplantation [120].”
BackgroundSelf-citationMitochondrial PO2 measured by delayed fluorescence of endogenous protoporphyrin IX
Mik, E. G., Stap, J., Sinaasappel, M., Beek, J. F., Aten, J. A., van Leeuwen, T. G., & Ince, C. (2006) · Nature Methods · doi:10.1038/nmeth940 · Cited by 168
Red Light-Excitable Oxygen Sensing Materials Based on Platinum(II) and Palladium(II) Benzoporphyrins
Borisov, S. M., Nuss, G., & Klimant, I. (2008) · Analytical Chemistry · doi:10.1021/ac801521v · Cited by 161 · cited 1×
“A number of related dye structures have been developed, including the phosphorescent Pt and Pd complexes of benzoporphyrins and porphyrin-ketones [31, 34, 35], which show longwave-shifted excitation bands (590–650 nm), emission at 730–900 nm (better suited for tissue imaging), and greater brightness [34, 36].”
BackgroundNishiyama, N., Nakagishi, Y., Morimoto, Y., Lai, P., Miyazaki, K., Urano, K., Horie, S., Kumagai, M., Fukushima, S., Cheng, Y., et al. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.10.010 · Cited by 160 · cited 1×
“For example, photosensitisers of porphyrin origin used in photodynamic therapy of cancer show maximal photodamage when they are targeted to cell membranes or the nuclei [98, 99].”
BackgroundLab-on-a-chip devices as an emerging platform for stem cell biology
Gupta, K., Kim, D., Ellison, D. D., Smith, C., Kundu, A., Tuan, J., Suh, K. Y., & Levchenko, A. (2010) · Lab on a Chip · doi:10.1039/c004689b · Cited by 160
On The Biomedical Promise of Cell Penetrating Peptides: Limits Versus Prospects
Foerg, C., & Merkle, H. P. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21117 · Cited by 157 · cited 2×
“whole structure into the cell by passive means and retain it inside [63].”
BackgroundIn Vivo Mitochondrial Oxygen Tension Measured by a Delayed Fluorescence Lifetime Technique
Mik, E. G., Johannes, T., Zuurbier, C. J., Heinen, A., Houben-Weerts, J. H. P. M., Balestra, G. M., Stap, J., Beek, J. F., & İnce, C. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.126094 · Cited by 151 · cited 4×
“More recently, detailed mapping and reconstruction of O2 gradients on a micro-scale and in 3-D have been demonstrated in tissue and even in individual cells [26, 81], which require thorough verification.”
BackgroundMethodInfluentialHynes, J., Marroquin, L. D., Ogurtsov, V. I., Christiansen, K. N., Stevens, G. J., Papkovsky, D. B., & Will, Y. (2006) · Toxicological Sciences · doi:10.1093/toxsci/kfj208 · Cited by 148 · cited 16×
“On the measurement side, the main parameters that require monitoring are (1) in situ oxygenation, (2) O2 consumption rate (OCR), and (3) localised O2 gradients within respiring samples, as well as the dynamics of these R. I. Dmitriev D. B. Papkovsky (&) Biochemistry Department, University College Cork, Cavanagh Pharma…”
BackgroundInfluentialSelf-citationTargeted Luminescent Near-Infrared Polymer-Nanoprobes for In Vivo Imaging of Tumor Hypoxia
Napp, J., Behnke, T., Fischer, L., Würth, C., Wottawa, M., Katschinski, D. M., Alves, F., Resch-Genger, U., & Schäferling, M. (2011) · Analytical Chemistry · doi:10.1021/ac201870b · Cited by 133
Oxygen advection and diffusion in a three-dimensional vascular anatomical network
Fang, Q., Sakadžić, S., Ruvinskaya, L., Devor, A., Dale, A. M., & Boas, D. A. (2008) · Optics Express · doi:10.1364/oe.16.017530 · Cited by 133 · cited 1×
“In recent years, wide-field FLIM systems and high-resolution confocal and two-photon laser-scanning systems [114] for imaging tissue O2 were successfully used in complex in vivo and ex vivo studies.”
BackgroundHuppert, T. J., Allen, M., Benav, H., Jones, P., & Boas, D. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600435 · Cited by 125 · cited 1×
“brain or muscle), localised O2 gradients in the vasculature (blood vessels, capillaries) or tumour oxygenation can be realised using extracellular O2 probes and phosphorescence lifetime-based O2 imaging [106, 111–113].”
BackgroundPrecipitation as a simple and versatile method for preparation of optical nanochemosensors
Borisov, S. M., Mayr, T., Mistlberger, G., Waich, K., Koren, K., Chojnacki, P., & Klimant, I. (2009) · Talanta · doi:10.1016/j.talanta.2009.05.041 · Cited by 117 · cited 2×
“polystyrene), inclusion of indicator dyes during emulsion polymerisation [68] and formation of core–shell nanostructures by a precipitation method [67].”
BackgroundMethodSchmälzlin, E., van Dongen, J. T., Klimant, I., Marmodée, B., Steup, M., Fisahn, J., Geigenberger, P., & Löhmannsröben, H. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.063453 · Cited by 116 · cited 2×
“The main detection modalities in O2 sensing are: (1) intensity measurements at a single wavelength; (2) ratiometric intensity measurements with a reference (O2insensitive) dye; and (3) lifetime based sensing by phase modulation technique [29, 79] or by time-gated fluorometry under pulsed excitation.”
BackgroundOxygen Tension Imaging in the Mouse Retina
Shonat, R. D., & Kight, A. C. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603256 · Cited by 112 · cited 8×
“CPP Cell-penetrating peptides EC Extracellular ecO2 Extracellular O2 FLIM Fluorescence/phosphorescence lifetime imaging microscopy IC Intracellular icO2 Intracellular O2 NP Nanoparticle(s) OCR Oxygen consumption rate PEG Poly(ethyleneglycol) RLD Rapid lifetime determination TR-F Time-resolved fluorescence/phosphoresce…”
BackgroundInfluentialNear Infrared Luminescent Oxygen Nanosensors with Nanoparticle Matrix Tailored Sensitivity
Lee, Y.-E. K., Ulbrich, E. E., Kim, G., Hah, H. J., Strollo, C. M., Fan, W., Gurjar, R. S., Koo, S., & Kopelman, R. (2010) · Analytical Chemistry · doi:10.1021/ac1015358 · Cited by 111 · cited 1×
“A more efficient strategy for cell loading is to develop O2 probes with cell-penetrating ability [42, 60–62] or to introduce ‘delivery vectors’ in existing probe structures [65].”
BackgroundSelf-referenced RGB colour imaging of intracellular oxygen
Wang, X., Gorris, H. H., Stolwijk, J. A., Meier, R. J., Groegel, D. B. M., Wegener, J., & Wolfbeis, O. S. (2011) · Chemical Science · doi:10.1039/c0sc00610f · Cited by 106
Determination of local oxygen consumption rates in tumors.
Dewhirst, M. W., Secomb, T. W., Ong, E. T., Hsu, R., & Gross, J. F. (1994) · PubMed · Cited by 99
Methods in Optical Oxygen Sensing: Protocols and Critical Analyses
Papkovsky, D. B. (2004) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(04)81046-2 · Cited by 97
Self-citationA Noninvasive Thin Film Sensor for Monitoring Oxygen Tension during in Vitro Cell Culture
Thomas, P. C., Halter, M. W., Tona, A., Raghavan, S. R., Plant, A. L., & Forry, S. P. (2009) · Analytical Chemistry · doi:10.1021/ac9013379 · Cited by 97 · cited 1×
“The highly photostable PtPFPP dye is actively used in a number of O2 sensing probes [37].”
BackgroundO’Riordan, T. C., Zhdanov, A. V., Ponomarev, G. V., & Papkovsky, D. B. (2007) · Analytical Chemistry · doi:10.1021/ac701770b · Cited by 97
Self-citationFLIM and FCS detection in laser‐scanning microscopes: Increased efficiency by GaAsP hybrid detectors
Becker, W., Su, B., Holub, O., & Weißhart, K. (2010) · Microscopy Research and Technique · doi:10.1002/jemt.20959 · Cited by 95 · cited 1×
“For the fluorescent redox indicators and other endogenous probes, including NAD(P)H and FAD, there are good opportunities for multiplexing with the phosphorescent probes; however, such studies are still rather scarce [74, 76, 77].”
BackgroundFluorescence-based cell viability screening assays using water-soluble oxygen probes
Hynes, J., Floyd, S., Soini, A. E., O'Connor, R., & Papkovsky, D. B. (2003) · SLAS Discovery · doi:10.1177/1087057103008003004 · Cited by 94
Self-citationComparison of methods for measuring oxygen consumption in tumor cells in vitro
Diepart, C., Verrax, J., Calderon, P. B., Feron, O., Jordan, B. F., & Gallez, B. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2009.09.029 · Cited by 92 · cited 4×
“Simple fluorescence intensity measurements can be used in these applications, with proper controls for possible optical interferences and measurement artefacts [19].”
BackgroundInfluentialMitochondrial oxygen tension within the heart
Mik, E. G., İnce, C., Eerbeek, O., Heinen, A., Stap, J., Hooibrink, B., Schumacher, C. A., Balestra, G. M., Johannes, T., Beek, J. F., et al. (2009) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.02.002 · Cited by 83 · cited 1×
“This methodology has been tested with cultured cells, isolated hepatocytes and in vivo with intact hearts [26, 74, 75].”
MethodHogan, M. C. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.720 · Cited by 71 · cited 3×
“For example, they were used in in situ respirometry with skeletal muscles [53, 102, 116], and in ex vivo imaging experiments with carotid body where cell oxygenation was correlated with the other parameters of cellular function [110].”
BackgroundMethodDetermination of PO2 and its heterogeneity in single capillaries
Zheng, L., Golub, A. S., & Pittman, R. N. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.271.1.h365 · Cited by 71
O’Riordan, T. C., Fitzgerald, K. T., Ponomarev, G. V., Mackrill, J. J., Hynes, J., Taylor, C. T., & Papkovsky, D. B. (2006) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00707.2006 · Cited by 68
Self-citationZhdanov, A. V., Ogurtsov, V. I., Taylor, C. T., & Papkovsky, D. B. (2010) · Integrative Biology · doi:10.1039/c0ib00021c · Cited by 68
Self-citationQuantifying the role of oxygen pressure in tissue function
Wilson, D. F. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01293.2007 · Cited by 65 · cited 1×
“Detailed understanding of the biological roles of O2 is of major fundamental and practical importance [1, 2].”
BackgroundIntracellular oxygen-sensitive phosphorescent probes based on cell-penetrating peptides
Dmitriev, R. I., Zhdanov, A. V., Ponomarev, G. V., Yashunski, D., & Papkovsky, D. B. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2009.10.048 · Cited by 65 · cited 1×
“a, b were generated with ecO2 probe MitoXpress TM [80]; c–e with pre-calibrated icO2 probes [61, 71] 2030 R.”
MethodSelf-citationTrityl-based EPR probe with enhanced sensitivity to oxygen
Bobko, A. A., Dhimitruka, I., Eubank, T. D., Marsh, C. B., Zweier, J. L., & Khramtsov, V. V. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.06.007 · Cited by 63 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], (19)F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundEsterified trityl radicals as intracellular oxygen probes
Liu, Y., Villamena, F. A., Sun, J., Wang, T.-Y., & Zweier, J. L. (2008) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2008.12.011 · Cited by 60 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], (19)F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundWon, Y., Moon, S., Yang, W., Kim, D., Han, W.-T., & Kim, D. Y. (2011) · Optics Express · doi:10.1364/oe.19.003396 · Cited by 60
Design of metalloporphyrin-based dendritic nanoprobes for two-photon microscopy of oxygen
Lebedev, A. Y., Troxler, T., & Vinogradov, S. A. (2008) · Journal of Porphyrins and Phthalocyanines · doi:10.1142/s1088424608000649 · Cited by 60 · cited 1×
“For example, they were used in in situ respirometry with skeletal muscles [53, 102, 116], and in ex vivo imaging experiments with carotid body where cell oxygenation was correlated with the other parameters of cellular function [110].”
MethodGolub, A. S., & Pittman, R. N. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01347.2007 · Cited by 60 · cited 1×
“For example, they were used in in situ respirometry with skeletal muscles [53, 102, 116], and in ex vivo imaging experiments with carotid body where cell oxygenation was correlated with the other parameters of cellular function [110].”
MethodGreger, K., Neetz, M., Reynaud, E. G., & Stelzer, E. H. K. (2011) · Optics Express · doi:10.1364/oe.19.020743 · Cited by 59
Zhdanov, A. V., Dmitriev, R. I., & Papkovsky, D. B. (2010) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-010-0502-8 · Cited by 57 · cited 1×
“It has been used in several mechanistic studies with complex biological models [83, 85, 86].”
MethodSelf-citationRancan, F., Wiehe, A., Nöbel, M., Senge, M. O., Omari, S. A., Böhm, F., John, M., & Röder, B. (2004) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2004.08.010 · Cited by 57 · cited 2×
“Having tested many different instruments and probes, we consider Victor (PerkinElmer, Finland) and FLUOstarOmega (BMG, Germany) TR-F reader families among the best in terms of their sensitivity and selectivity of probe detection (S/N ratio [100), accuracy and resolution in RLD mode and temperature control.”
BackgroundMethodA Clark-type oxygen chip for in situ estimation of the respiratory activity of adhering cells
Wu, C.-C., Luk, H., Lin, Y.-T. T., & Yuan, C.-Y. (2009) · Talanta · doi:10.1016/j.talanta.2009.11.062 · Cited by 56 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundClinical Electron Paramagnetic Resonance (EPR) Oximetry Using India Ink
Williams, B. B., Khan, N. I., Zaki, B. I., Hartford, A. C., Ernstoff, M. S., & Swartz, H. M. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_21 · Cited by 56
Dmitriev, R. I., Ropiak, H. M., Ponomarev, G. V., Yashunsky, D. V., & Papkovsky, D. B. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200324q · Cited by 55
Self-citationHarms, F. A., de Boon, W. M. I., Balestra, G. M., Bodmer, S. I. A., Johannes, T., Stolker, R. J., & Mik, E. G. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100040 · Cited by 52 · cited 1×
“For the fluorescent redox indicators and other endogenous probes, including NAD(P)H and FAD, there are good opportunities for multiplexing with the phosphorescent probes; however, such studies are still rather scarce [74, 76, 77].”
BackgroundOptical monitoring of oxygen tension in cortical microvessels with confocal microscopy
Yaseen, M. A., Srinivasan, V. J., Sakadžić, S., Wu, W., Ruvinskaya, S., Vinogradov, S. A., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.022341 · Cited by 51 · cited 2×
“For example, they were used in in situ respirometry with skeletal muscles [53, 102, 116], and in ex vivo imaging experiments with carotid body where cell oxygenation was correlated with the other parameters of cellular function [110].”
BackgroundMethodOxygen Distribution and Consumption in the Developing Rat Retina
Cringle, S. J., Yu, P. K., Su, E., & Yu, D. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1638 · Cited by 50 · cited 1×
“Solid-state sensors are usually used in O2 microsensors [12], sensor coatings [49] and integrated systems [50].”
BackgroundP o 2 profiles near arterioles and tissue oxygen consumption in rat mesentery
Golub, A. S., Barker, M. C., & Pittman, R. N. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00077.2007 · Cited by 47 · cited 1×
“Other in vivo studies include: O2 mapping of rodent retina where the application of anaesthetics was shown to decrease venous O2 tension [54, 106]; O2 dynamics in individual frog skeletal muscle fibres showing that faster frequency of muscle stimulation leads to higher drops in pO2 in adaptive manner [116]; measuremen…”
BackgroundPhotoacoustic probing of fluorophore excited state lifetime with application to oxygen sensing
Ashkenazi, S., Huang, S.-W., Horvath, T. D., Koo, Y.-E. L., & Kopelman, R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2927466 · Cited by 46 · cited 1×
“Facilitated transport systems, such as microinjection, electroporation [66], facilitated endocytosis [80, 93], liposomal transfer and gene gun [95], have been used with some success, but these techniques require additional reagents/steps, and are tedious, invasive and stressful for the cells.”
BackgroundCeroni, P., Lebedev, A. Y., Marchi, E. B., Yuan, M., Esipova, T. V., Bergamini, G., Wilson, D. F., Busch, T. M., & Vinogradov, S. A. (2011) · Photochemical & Photobiological Sciences · doi:10.1039/c0pp00356e · Cited by 45
In vivo oxygen imaging using green fluorescent protein
Takahashi, E., Takano, T., Nomura, Y., Okano, S., Nakajima, O., & Sato, M. (2006) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00067.2006 · Cited by 44 · cited 3×
“This has been demonstrated with several supramolecular- and nanoparticle-based probes, for which fast (6–16 h) and efficient cell loading comparable with the delivery of conventional small molecule cargo or cell transfection with genetically-encoded biosensor probes [25, 96] was achieved.”
BackgroundPhosphorescence quenching microrespirometry of skeletal muscle in situ
Golub, A. S., Tevald, M. A., & Pittman, R. N. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00626.2010 · Cited by 44
A robotic system for ‐FMISO PET‐guided intratumoral measurements
Chang, J., Wen, B., Kazanzides, P., ZANZONICO, P. B., Finn, R. D., Fichtinger, G., & Ling, C. (2009) · Medical Physics · doi:10.1118/1.3239491 · Cited by 43
Dynamics of Intracellular Oxygen in PC12 Cells upon Stimulation of Neurotransmission
Zhdanov, A. V., Ward, M. W., Prehn, J. H. M., & Papkovsky, D. B. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m706439200 · Cited by 41 · cited 1×
“It has been used in several mechanistic studies with complex biological models [83, 85, 86].”
MethodSelf-citationIn vitro O2 uptake and histochemical fiber type of resting hamster muscles
Sullivan, S. M., & Pittman, R. N. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.1.246 · Cited by 40 · cited 2×
“PdTPCPP Pd(II)-meso-tetra-(4-carboxyphenyl)porphyrin, PdTCPTBP Pd(II)-meso-tetra-(4-carboxyphenyl)tetrabenzoporphyrindendrimer, PtCP Pt(II)coproporphyrin, PtTBP Pt(II)-meso-tetrabenzoporphyrin, butyl octaester, PtCPK Pt(II)-coproporphyrin-ketone, Ir(III)(Cx)2(acac) cyclometalatedIr(III) l-chloro-bridged dimer coumarin…”
BackgroundMethodComparative bioenergetic assessment of transformed cells using a cell energy budget platform
Zhdanov, A. V., Favre, C., O′Flaherty, L., Adam, J., O’Connor, R., Pollard, P. J., & Papkovsky, D. B. (2011) · Integrative Biology · doi:10.1039/c1ib00050k · Cited by 39
Self-citationImaging of oxygen gradients in monolayer cultured cells using green fluorescent protein
Takahashi, E., & Sato, M. (2010) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00254.2010 · Cited by 39 · cited 4×
“Some fluorescent proteins of GFP family produce an O2-dependent red shift in fluorescence upon their photoactivation with blue light [25].”
MethodInfluentialLiu, Q., & Vo‐Dinh, T. (2009) · Medical Physics · doi:10.1118/1.3218763 · Cited by 37 · cited 1×
“More recently, they have been extended by microelectrodes [12–14], systems for adherent cells [15, 16], EPR probes [17, 18], (19)F MRI [19, 20], pimonidazole staining [21], and fibre-optic sensing [22], and enhanced by the technological advancements in”
BackgroundBactenecin 7 peptide fragment as a tool for intracellular delivery of a phosphorescent oxygen sensor
Dmitriev, R. I., Ropiak, H. M., Yashunsky, D. V., Ponomarev, G. V., Zhdanov, A. V., & Papkovsky, D. B. (2010) · FEBS Journal · doi:10.1111/j.1742-4658.2010.07872.x · Cited by 34 · cited 3×
“Another group of supramolecular probes are conjugates of the phosphorescent dyes with cell-penetrating peptides (CPP) for sensing intracellular O2 [42, 60–62].”
BackgroundMethodSelf-citationZhdanov, A. V., Ward, M. W., Taylor, C. T., Souslova, E. A., Chudakov, D. M., Prehn, J. H. M., & Papkovsky, D. B. (2010) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2010.06.006 · Cited by 33
Self-citationHynes, J., Natoli, E. J., & Will, Y. (2009) · Current Protocols in Toxicology · doi:10.1002/0471140856.tx0216s40 · Cited by 29 · cited 3×
“To measure absolute OCR values, a sealed, gasimpermeable vessel should be used [58].”
BackgroundMethodZítová, A., O’Mahony, F. C., Cross, M., Davenport, J., & Papkovsky, D. B. (2008) · Environmental Toxicology · doi:10.1002/tox.20387 · Cited by 29 · cited 1×
“MitoXpress probe [33] from this category is now actively used in respirometric screening assays with isolated mitochondria, adherent and suspension mammalian and microbial cells [57], small organisms, and with compound libraries and environmental samples [58, 59].”
BackgroundSelf-citationMulti‐dimensional fluorescence microscopy of living cells
Schneckenburger, H., Wagner, M., Weber, P., Bruns, T., Richter, V., Strauß, W. S. L., & Wittig, R. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000098 · Cited by 14 · cited 1×
“Nowadays, the focus is shifting towards more complex models and real-life systems: adherent differentiated cells [83–86], ex vivo and in vivo systems, such as intact respiring brain, muscle, tumour tissue and vasculature [90, 91].”
BackgroundLive cell imaging : methods and protocols
Papkovsky, D. B. (2010) · Humana Press eBooks · Cited by 14
Self-citationHowlett, R. A., Kindig, C. A., & Hogan, M. C. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00422.2006 · Cited by 11 · cited 1×
“On the application side, initial bioenergetic, metabolic, cell biology and toxicological studies using O2-sensing techniques have been applied to rather simple, macroscopic samples, such as mitochondrial preparations [118], suspension cell lines [57] and perfused respiring tissue [24].”
Background
Cited by
Porphyrinoids for Chemical Sensor Applications
Paolesse, R., Nardis, S., Monti, D., Stefanelli, M., & Di Natale, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00361 · Cited by 874
Analysis and Interpretation of Microplate-Based Oxygen Consumption and pH Data
Divakaruni, A. S., Paradyse, A., Ferrick, D. A., Murphy, A. N., & Jastroch, M. (2014) · Methods in Enzymology · doi:10.1016/b978-0-12-801415-8.00016-3 · Cited by 518
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Self-citationKeeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Generation of Singlet Oxygen by Photoexcited Au25(SR)18 Clusters
Kawasaki, H., Kumar, S., Li, G., Zeng, C., Kauffman, D. R., Yoshimoto, J., Iwasaki, Y., & Jin, R. (2014) · Chemistry of Materials · doi:10.1021/cm500260z · Cited by 314
Metadata
- Authors
- Dmitriev, R. I., & Papkovsky, D. B.
- Venue
- Cellular and Molecular Life Sciences
- Published
- 2012-01-17
- Volume
- 69
- Issue
- 12
- Pages
- 2025-2039
- ISSN
- 1420-682X (ISSN-L)
- 1420-9071
- OpenAlex
- W1973273142
- Cited by
- 230
- References
- 98
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.