The Road to Bioabsorbable Stents: Reaching Clinical Reality?
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
This article provides an overview of the evolution of revascularization devices since Grüntzig's initial introduction of balloon angioplasty in 1977. In-stent restenosis (ISR) is the major shortcoming of conventional (permanent-implant) stent therapy; even with the innovation and promising benefits of drug-eluting stents, management of ISR is very difficult. ISR is mainly caused by the interaction between the blood and the stent surface and a permanent mechanical irritation of the vascular tissue. Thus stenting technology has moved toward the development of temporary implants composed of biocompatible materials which mechanically support the vessel during the period of high risk for recoil and then completely biodegrade in the long term. Preclinical and first clinical experiences with bioabsorbable magnesium stents are discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892 · cited 1×
“In 1987 Sigwart described the use of coronary stents [2], which had the potential to treat dissections.”
BackgroundIntracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428 · cited 1×
“Colombo subsequently demonstrated that stent thrombosis could be significantly reduced through achievement of highpressure stent expansion and the combined administration of aspirin and the thienopyridine ticlopidine [3, 4].”
BackgroundAngiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258 · cited 1×
“The incidence of ISR is particularly high in cases where stents are implanted in complex lesions involving bifurcations, long lesions and small vessels or in patients with diabetes [6, 7].”
BackgroundPatterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247 · cited 4×
“Intravascular ultrasound (IVUS) has demonstrated that negative remodeling (shrinkage of the arterial wall diame-Correspondence to: Prof. Dr. Paul Erne, M.D.; email: Paul.Erne@KSL.CH ter) is the main component responsible for restenosis in post-PTCA lesions [12].”
BackgroundInfluentialCatheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889 · cited 1×
“ter) is the main component responsible for restenosis in post-PTCA lesions [12].”
Backgroundvan der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852 · cited 1×
“Although minimal inflammation using the poly-l-lactic acid stent in a dog model was demonstrated [34], other biodegradable polymers including polyglycolic acid/polylactic acid, polycaprolactone, polyhydroxybutyrate valerate, polyorthoester, and polyethyleneoxide/polybutylene terephthalate were subsequently tested in a…”
MethodBiocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806 · cited 1×
“novel zigzag helical coiled design (as opposed to a mesh design) produced acceptably low inflammatory and scarring responses after experimental [42] and clinical implantation [43].”
BackgroundTextbook of interventional cardiology
Topol, E. J. (1994) · Cited by 710
Research works printed but not linked: 2
- Duda SH, Pusich B, Richter G, et al. (2002) Sirolimus-eluting stents for the treatment of obstructive superficial femoral arte\rventions in iliac and infrainguinal occlusive artery disease. J Interv Cardiol 17:427–435
- Sawyer P, Brattain W, Boddy P (1965) Electrochemical criteria in the choice of materials used in vascular prosthesis. In: Sawyer P (ed) Biophysical mechanism in vascular hemostasis and intravascular thrombosis. Appleton-Century-Crofts, New York, pp 337–348
Cited by
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
“Deploying them not only abrogates the need for implant-removal surgery, but also circumvents the long-term negative effects of permanent implant”
BackgroundProgress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Rajeshkumar, G., Arvindh Seshadri, S., Devnani, G. L., Sanjay, M. R., Siengchin, S., Prakash Maran, J., Al-Dhabi, N. A., Karuppiah, P., Mariadhas, V. A., Sivarajasekar, N., et al. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127483 · Cited by 640
Metadata
- Authors
- Erne, P., Schier, M., & Resink, T. J.
- Affiliations
- Biotronik (Germany) (DE)
- Venue
- CardioVascular and Interventional Radiology
- Published
- 2005-09-29
- Volume
- 29
- Issue
- 1
- Pages
- 11-16
- ISSN
- 0174-1551 (ISSN-L)
- 1432-086X
- OpenAlex
- W1985328726
- Cited by
- 249
- References
- 59
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 12 · 2021: 12 · 2020: 12 · 2019: 12 · 2018: 10 · 2017: 19 · 2016: 13 · 2015: 19 · 2014: 20 · 2013: 19 · 2012: 14
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- CardioVascular and Interventional Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- biodegradable stents, in-stent restenosis, drug-eluting stents, magnesium stents, coronary revascularization, balloon angioplasty, biodegradable implants, biomaterials, stent recoil, vascular injury
- MeSH terms
- Coronary Artery Disease, Humans, Iron, Magnesium, Polymers, Stents, Drug Delivery Systems, Absorbable Implants, Coronary Restenosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.