The Road to Bioabsorbable Stents: Reaching Clinical Reality?
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
This article provides an overview of the evolution of revascularization devices since Grüntzig's initial introduction of balloon angioplasty in 1977. In-stent restenosis (ISR) is the major shortcoming of conventional (permanent-implant) stent therapy; even with the innovation and promising benefits of drug-eluting stents, management of ISR is very difficult. ISR is mainly caused by the interaction between the blood and the stent surface and a permanent mechanical irritation of the vascular tissue. Thus stenting technology has moved toward the development of temporary implants composed of biocompatible materials which mechanically support the vessel during the period of high risk for recoil and then completely biodegrade in the long term. Preclinical and first clinical experiences with bioabsorbable magnesium stents are discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Textbook of interventional cardiology
Topol, E. J. (1994) · Cited by 710
Serruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Coronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Grewe, P. H., Deneke, T., Machraoui, A., Barmeyer, J., & Müller, K.-M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00486-6 · Cited by 401
Intracoronary ultrasound observations during stent implantation.
Nakamura, S., Colombo, A., Gaglione, A., Almagor, Y., Goldberg, S. L., Maiello, L., Finci, L., & Tobis, J. M. (1994) · Circulation · doi:10.1161/01.cir.89.5.2026 · Cited by 394
Late Coronary Occlusion After Intracoronary Brachytherapy
Costa, M. A., Sabaté, M., van der Giessen, W. J., Kay, I. P., Cervinka, P., Ligthart, J. M. R., Serrano, P., Coen, V. L. M. A., Levendag, P. C., & Serruys, P. W. (1999) · Circulation · doi:10.1161/01.cir.100.8.789 · Cited by 389
Condado, J. A., Waksman, R., Gurdiel, O., Espinosa, R., Gonzalez, J., Burger, B., Villoria, G., Acquatella, H., Crocker, I. R., Seung, K. B., et al. (1997) · Circulation · doi:10.1161/01.cir.96.3.727 · Cited by 348
Textbook of Interventional Cardiology
Bresnahan, J. F. (1995) · Mayo Clinic Proceedings · doi:10.4065/70.7.719 · Cited by 342
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B. (2005) · Journal of Endovascular Therapy · doi:10.1583/04-1349r.1 · Cited by 275
Pathology of in-stent restenosis
Virmani, R., & Farb, A. (1999) · Current Opinion in Lipidology · doi:10.1097/00041433-199912000-00004 · Cited by 240
IN-STENT STENOSIS: PATHOLOGY AND IMPLICATIONS FOR THE DEVELOPMENT OF DRUG ELUTING STENTS
Bennett, M. R. (2003) · Heart · doi:10.1136/heart.89.2.218 · Cited by 197
Biodegradable Stents: “Fulfilling the Mission and Stepping Away”
Colombo, A., & Karvouni, E. (2000) · Circulation · doi:10.1161/01.cir.102.4.371 · Cited by 182
Late Thrombosis After Radiation: Sitting on a Time Bomb
Waksman, R. (1999) · Circulation · doi:10.1161/01.cir.100.8.780 · Cited by 175
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
VOGT, F. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.010 · Cited by 174
Stent development and local drug delivery
Regar, E., Sianos, G., & Serruys, P. W. (2001) · British Medical Bulletin · doi:10.1093/bmb/59.1.227 · Cited by 158
Yamawaki, T., Shimokawa, H., Kozai, T., Miyata, K., Higo, T., Tanaka, E., Egashira, K., Shiraishi, T., Tamai, H., Igaki, K., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00312-x · Cited by 156
Magnesium and cardiovascular disease
Arsenian, M. A. (1993) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(93)90008-2 · Cited by 145
Coronary restenosis: a review of mechanisms and management
Rajagopal, V., & Rockson, S. G. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00477-7 · Cited by 139
Interventional cardiac catheterization at Duke Medical Center.
Stack, R. S., Califf, R. M., Phillips, H. R., Pryor, D. B., Quigley, P. J., Bauman, R. P., Tcheng, J. E., & Greenfield, J. C. (1988) · The American Journal of Cardiology · Cited by 126
Review of corrosion and corrosion control of magnesium alloys and composites
Ferrando, W. A. (1989) · Journal of Materials Engineering · doi:10.1007/bf02834140 · Cited by 125
Molecular Mechanisms of In-Stent Restenosis and Approach to Therapy with Eluting Stents
Indolfi, C., Mongiardo, A., Antonio, C., & Torella, D. (2003) · Trends in Cardiovascular Medicine · doi:10.1016/s1050-1738(03)00038-0 · Cited by 116
Woods, T. C., & Marks, A. R. (2004) · Annual Review of Medicine · doi:10.1146/annurev.med.55.091902.105243 · Cited by 114
Influence of stent design and material composition on procedure outcome
Palmaz, J. C., Bailey, S., Marton, D., & Sprague, E. A. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.129113 · Cited by 93
The Duke Interventional Cardiac Catheterization Progam
(1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91529-9 · Cited by 74
[The percutaneous dilatation of chronic coronary stenoses--experiments and morphology].
Grüntzig, A., & Schneider, H. J. (1977) · PubMed · Cited by 69
Current Status of Biodegradable Stents
Tanguay, J. F., Zidar, J. P., Phillips, H. R., & Stack, R. S. (1994) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30086-9 · Cited by 63
Saia, F., Lemos, P. A., Hoye, A., Sianos, G., Arampatzis, C. A., de Feyter, P. J., van der Giessen, W. J., Smits, P. C., van Domburg, R. T., & Serruys, P. W. J. C. (2004) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20068 · Cited by 54
Magnesium and Cardiovascular Disease
Gomez, M. N. (1998) · Anesthesiology · doi:10.1097/00000542-199807000-00029 · Cited by 45
Results of Coronary Stenting for Restenosis
Colombo, A., Ferraro, M., Itoh, A., Martini, G., Blengino, S., & Finci, L. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00266-5 · Cited by 41
Endovascular Interventions in Iliac and Infrainguinal Occlusive Artery Disease
Ruef, J., Hofmann, M., & Haase, J. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04086.x · Cited by 39
Biomaterialien – humane Toleranz und Integration
Wintermantel, E., Mayer, J., Ruffieux, K., Bruinink, A., & Eckert, K.-L. (1999) · Der Chirurg · doi:10.1007/s001040050734 · Cited by 38
Novel Approaches to Reduce Restenosis
Beyar, R. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1302.032 · Cited by 33
Biodegradable Stents: The Future of Interventional Cardiology?
Labinaz, M. X., Zidar, J. P., Stack, R. S., & Phillips, H. R. (1995) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1995.tb00565.x · Cited by 33
New advances in endovascular technology.
Palmaz, J. C. (1997) · Europe PMC (PubMed Central) · Cited by 26
Classification and Current Treatment Options of In-Stent Restenosis
Ong, A. T. L., Aoki, J., McFadden, E. P., & Serruys, P. W. J. C. (2004) · Herz · doi:10.1007/s00059-004-2574-4 · Cited by 26
Intracoronary radiation with gamma wire inhibits recurrent in-stent restenosis
Waksman, R., Bhargava, B., Chan, R. C., Sherman, W., Pisch, J., Mintz, G. S., Lansky, A. J., Ahmed, J. M., Ricci, N. A., & Liprie, S. F. (2001) · Cardiovascular Radiation Medicine · doi:10.1016/s1522-1865(00)00086-x · Cited by 18
The challenge of in-stent restenosis: insights from intravascular ultrasound
Spanos, V., Stankovic, G. R., Tobis, J. M., & Colombo, A. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00418-9 · Cited by 17
Magnesium in Cardiovascular Disease
Stühlinger, H. G. (2002) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 14
Magnesium deficiency and cardiovascular disease
Vitale, J. J. (1992) · The Lancet · doi:10.1016/0140-6736(92)92926-7 · Cited by 14
Intravascular Brachytherapy: A Review of the Current Vascular Biology
Apisarnthanarax, S., & Chougule, P. B. (2003) · American Journal of Clinical Oncology · doi:10.1097/01.coc.0000072502.34681.f4 · Cited by 12
Vasopressin-induced activation of human blood platelets: prominent role of Mg2+
Erné, P., & Pletscher, A. (1985) · Naunyn-Schmiedeberg s Archives of Pharmacology · doi:10.1007/bf00695199 · Cited by 10
Doriot, P. A., Dorsaz, P. ‐., & Verin, V. E. (2003) · Cardiovascular Radiation Medicine · doi:10.1016/s1522-1865(03)00147-1 · Cited by 7
Altura, B. M., & Altura, B. T. (1993) · PubMed · Cited by 7
The importance of magnesium in cardiovascular disease
Keller, K., & Lemberg, L. (1993) · American Journal of Critical Care · doi:10.4037/ajcc1993.2.4.348 · Cited by 7
Badger, J. M. (1994) · The Journal of Cardiovascular Nursing · doi:10.1097/00005082-199410000-00005 · Cited by 5
[Therapeutic use of magnesium].
Ow, L., & Bores, W. (1951) · PubMed · Cited by 2
The role of magnesium in cardiovascular disease.
Kayser, S. R., & Trujillo, T. (1994) · PubMed · Cited by 2
Research works printed but not linked: 2
- Duda SH, Pusich B, Richter G, et al. (2002) Sirolimus-eluting stents for the treatment of obstructive superficial femoral arte\rventions in iliac and infrainguinal occlusive artery disease. J Interv Cardiol 17:427–435
- Sawyer P, Brattain W, Boddy P (1965) Electrochemical criteria in the choice of materials used in vascular prosthesis. In: Sawyer P (ed) Biophysical mechanism in vascular hemostasis and intravascular thrombosis. Appleton-Century-Crofts, New York, pp 337–348
Cited by
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Progress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Rajeshkumar, G., Arvindh Seshadri, S., Devnani, G. L., Sanjay, M. R., Siengchin, S., Prakash Maran, J., Al-Dhabi, N. A., Karuppiah, P., Mariadhas, V. A., Sivarajasekar, N., et al. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127483 · Cited by 640
Metadata
- Authors
- Erne, P., Schier, M., & Resink, T. J.
- Affiliations
- Biotronik (Germany) (DE)
- Venue
- CardioVascular and Interventional Radiology
- Published
- 2005-09-29
- Volume
- 29
- Issue
- 1
- Pages
- 11-16
- ISSN
- 0174-1551 (ISSN-L)
- 1432-086X
- OpenAlex
- W1985328726
- Cited by
- 249
- References
- 59
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 12 · 2021: 12 · 2020: 12 · 2019: 12 · 2018: 10 · 2017: 19 · 2016: 13 · 2015: 19 · 2014: 20 · 2013: 19 · 2012: 14
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- CardioVascular and Interventional Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- biodegradable stents, in-stent restenosis, drug-eluting stents, magnesium stents, coronary revascularization, balloon angioplasty, biodegradable implants, biomaterials, stent recoil, vascular injury
- MeSH terms
- Coronary Artery Disease, Humans, Iron, Magnesium, Polymers, Stents, Drug Delivery Systems, Absorbable Implants, Coronary Restenosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.