Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
A placement effect on activity measures from movement sensors has been reported during treadmill and free-living activity. Positioning of electrodes may impact on movement artifact susceptibility as well as surface ECG waveform amplitudes and thus potentially on the precision by which heart rate (HR) is ascertained from such ECG traces. The purpose of this study was to examine the extent to which placement of the combined HR and movement sensor, Actiheart, influences measurement of HR and movement, and estimates of energy expenditure. A total of 24 participants (20-39 years, 45-109 kg, 1.54-2.05 m, 19-29 kg m(-2)) were recruited. Whilst wearing two monitors, one placed at the level of the third intercostal space (upper position) and one just below the apex of the sternum (lower position), study participants performed level walking, incline walking, and level running on treadmill, and completed at least one day of free-living monitoring. Placement differences in HR data quality, movement counts, and energy expenditure (estimated from combined HR and movement) were analyzed with regression techniques. Quality of HR data was generally higher when monitors were placed in the lower position. This effect was more pronounced in men during both treadmill activity (relative risk, RR [95% CI] of noisy HR data in upper vs. lower position, RR=1.3[0.3; 5.6] in women, RR=174[14; 2,156] in men) and during free-living (RR=1.2[0.4; 3.3] in women, RR=25[9.6; 67] in men). There were minor place…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 2×
“…along with higher ECG amplitudes, both of which may contribute to more reliable HR readings since commonly used mathematical algorithms may easily detect QRS complexes due to higher signal-to-noise ratio (Horan et al. 1980; Pan and Tompkins 1985; Schijvenaars et al. 1997; Searle and Kirkup 2000).”
BackgroundAge-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1×
“When participants were unable to complete the protocol, HR had reached at least 90% of age-predicted maximal HR (Tanaka et al. 2001).”
BackgroundThe sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804 · cited 1×
“This component increases with increasing running intensity, whilst the vertical component remains relatively constant (Cavagna et al. 1976; Chang and Kram 1999).”
BackgroundA direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725 · cited 4×
“…which type of electrode to use, since conductive, adhesive, and allergenic properties are different between electrode types (Ask et al. 1979; Burke and Gleeson 2000; Fernandez and Pallas-Areny 2000; Geddes et al. 1962; Hagemann et al. 1985; Patterson 1978; Searle and Kirkup 2000; Xu et al. 1999).”
BackgroundInfluentialReliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667 · cited 9×
“One limitation of the present study was that golden standard ECG was not available to perform agreement analysis with Actiheart measured HR in the two positions, although the HR algorithm has been successfully validated against ECG in a previous study (Brage et al. 2005).”
BackgroundMethodInfluentialSelf-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 8×
“Data are mean PAI (robust SE) in J min 1 kg 1 (treadmill) or PAEE in kJ day 1 kg 1 (free-living) and corresponding epoch utilization (percentage of total, branch 1/2/3/4) in the branched model (Brage et al. 2004) *P<0.”
BackgroundMethodResultInfluentialSelf-citationA comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343 · cited 4×
“To our knowledge, there are no other studies which have assessed the effect of placement on accelerometers attached to the two positions used in this study but Welk and colleagues reported a placement effect for the uni-axial CSA accelerometer (also known as the MTI Actigraph) but not for the tri-axial Tritrac and the…”
BackgroundInfluentialEndurance training does not enhance total energy expenditure in healthy elderly persons
Goran, M. I., & Poehlman, E. T. (1992) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1992.263.5.e950 · Cited by 275 · cited 2×
“…comparisons between different cultural settings and time eras, and finally in lifestyle intervention studies to ascertain the extent to which the intervention was delivered or indeed accompanied by compensatory behavior in other activity domains (Goran and Poehlman 1992; Wareham and Rennie 1998).”
BackgroundWareham, N. J., & Rennie, K. L. (1998) · PubMed · Cited by 256
Self-citationRehrig, P. W., Park, S.-E., Trolier-McKinstry, S., Messing, G. L., Jones, B., & Shrout, T. R. (1999) · Journal of Applied Physics · doi:10.1063/1.370943 · Cited by 231
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Self-citationWarren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Self-citationAssessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
“However, the general shortcoming of heart rate monitoring over longer time under free-living conditions still is the data quality (Brage et al. 2006).”
BackgroundDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
MethodSelf-citationPhysical Activity and Pregnancy: Cardiovascular Adaptations, Recommendations and Pregnancy Outcomes
Melzer, K., Schutz, Y., Boulvain, M., & Kayser, B. (2010) · Sports Medicine · doi:10.2165/11532290-000000000-00000 · Cited by 314
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
“After light preparation of the skin, ECG electrodes (Red Dot 2570; 3M) were applied on the left side of the chest, with the medial electrode placed just below the apex of the sternum and the lateral electrode placed 12–13 cm horizontally from there [lower position (9)].”
MethodInfluentialSelf-citationStahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276
Gaussian process robust regression for noisy heart rate data
Stegle, O., Fallert, S. V., MacKay, D. J. C., & Brage, S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923118 · Cited by 213
“This dataset was recorded with two separate sensors on the same individual, one placed at the level of the third intercostal space (upper sensor) and the other placed below the apex of the sternum (lower sensor) [17].”
MethodSelf-citationSchrack, J. A., Zipunnikov, V., Goldsmith, J., Bai, J., Simonsick, E. M., Crainiceanu, C., & Ferrucci, L. (2014) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt199 · Cited by 210
“Such chest level placement has been found to be accurate and reliable for measuring daily activity counts (12,13).”
BackgroundBrage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“Heart rate and acceleration were measured in all tests with a combined sensor (Actiheart, CamNtech Ltd, Papworth, UK), attached to standard ECG electrodes (Red Dot 2570, 3M) at the level just below the apex of the sternum as described elsewhere [11,26].”
MethodSelf-citationGeneralized Multilevel Function-on-Scalar Regression and Principal Component Analysis
Goldsmith, J., Zipunnikov, V., & Schrack, J. A. (2015) · Biometrics · doi:10.1111/biom.12278 · Cited by 176
“The subject-level and subject-visit-level effects (bi(t) and vij(t), respectively) are assumed to be independent and will be decomposed using a multilevel functional principal components analysis that separates within- and between-subject directions of variability (Di et al., 2009). Principal component basis functions…”
BackgroundInfluentialHealth‐related aspects of objectively measured daily physical activity in children
Dencker, M., & Andersen, L. B. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00788.x · Cited by 136
Effects of recommended levels of physical activity on pregnancy outcomes
Melzer, K., Schutz, Y., Soehnchen, N., Othenin-Girard, V., Martinez de Tejada, B., Irion, O., Boulvain, M., & Kayser, B. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.10.876 · Cited by 133
Assah, F. K., Ekelund, U., Brage, S., Wright, A., Mbanya, J. C., & Wareham, N. J. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyq098 · Cited by 132
Self-citationHalsey, L. G., Shepard, E. L. C., Hulston, C. J., Venables, M., White, C. R., Jeukendrup, A. E., & Wilson, R. P. (2008) · Zoology · doi:10.1016/j.zool.2007.07.011 · Cited by 153
Stamatakis, E., Huang, B.-H., Maher, C., Thøgersen-Ntoumani, C., Stathi, A., Dempsey, P. C., Johnson, N., Holtermann, A., Chau, J. Y., Sherrington, C., et al. (2021) · Sports Medicine · doi:10.1007/s40279-020-01368-8 · Cited by 113
Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic Review
Allet, L., Knols, R. H., Shirato, K., & Bruin, E. D. D. (2010) · Sensors · doi:10.3390/s101009026 · Cited by 118
“, with an ActiHeart device [68-70].”
Villars, C., Bergouignan, A., Dugas, J., Antoun, E., Schoeller, D. A., Roth, H., Maingon, A. C., Lefai, E., Blanc, S., & Simon, C. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01413.2011 · Cited by 107
“However, the Actiheart monitor, which is based on such an approach, was mainly validated against indirect calorimetry during standardized laboratory activities and in a field-setting study that does not really reflect activity patterns of daily life (2, 9, 15, 29, 33).”
BackgroundCollings, P. J., Wijndaele, K., Corder, K., Westgate, K., Ridgway, C. L., Dunn, V., Goodyer, I., Ekelund, U., & Brage, S. (2014) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-11-23 · Cited by 106
“This was attached to the participant’s chest by two ECG electrodes, one placed medially at the base of the sternum and the other horizontally to the left side without the adjoining wire being too taught [28].”
MethodSelf-citationBonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2010) · Obesity · doi:10.1038/oby.2010.34 · Cited by 100
“Likewise, accelerometers have been coupled to heart rate monitors to increase the accuracy in the AEE estimation (7,16).”
Methodde Hollander, E. L., Zwart, L., de Vries, S. I., & Wendel‐Vos, W. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2011.05.005 · Cited by 120
“TheActiheart is a valid instrument inmeasuring daily life activities, better able to calculate energy expenditure, and able to make a distinction in the intensity of activities on an individual basis [9,12].”
BackgroundMethodAssociations between children’s independent mobility and physical activity
Schöeppe, S., Duncan, M. J., Badland, H. M., Oliver, M., & Browne, M. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-91 · Cited by 129
“The Actiheart was attached directly onto the skin on the lower left side of the chest using two electrocardiograph (ECG) electrodes (model Red Dot 2238 soft cloth, 3 M) [33,34].”
MethodSelf-Report vs. Objectively Assessed Physical Activity: Which Is Right for Public Health?
Loney, T., Standage, M., Thompson, D., Sebire, S. J., & Cumming, S. (2011) · Journal of Physical Activity and Health · doi:10.1123/jpah.8.1.62 · Cited by 89
Advances in physical activity monitoring and lifestyle interventions in obesity: a review
Bonomi, A. G., & Westerterp, K. R. (2011) · International Journal of Obesity · doi:10.1038/ijo.2011.99 · Cited by 109
Validation of the Actiheart Monitor for the Measurement of Physical Activity
Barreira, T., Kang, M., Caputo, J., Farley, R., & Renfrow, M. (2009) · International Journal of Exercise Science · doi:10.70252/ltrb1450 · Cited by 76
“(1) also investigated the intra-instrument reliability during treadmill locomotion and freeliving.”
BackgroundFaurholt‐Jepsen, M., Brage, S., Vinberg, M., Christensen, E. M., Knorr, U., Jensen, H. M., & Kessing, L. V. (2012) · Journal of Affective Disorders · doi:10.1016/j.jad.2012.02.020 · Cited by 84
Self-citationBock, F. D., Fischer, J. E., Hoffmann, K., & Renz‐Polster, H. (2010) · BMC Public Health · doi:10.1186/1471-2458-10-49 · Cited by 73
“According to the measurement protocol, the Actiheart monitors are programmed and securely affixed to each child’s substernal thorax [40] by two sticky electrodes (Kendall Arbo*ECG electrodes, Tyco Healthcare, Neustadt Donau, Germany) and additional tape.”
MethodKoch, M., Lunde, L.-K., Gjulem, T. S., Knardahl, S., & Veiersted, K. B. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162881 · Cited by 63
“To measure heart rate, an Actiheart monitor (Camntech, Cambridge, United Kingdom) was attached at the apex of the sternum and at the left intercostals at the level of the sixth and seventh costae [29].”
MethodPregnancy-related changes in activity energy expenditure and resting metabolic rate in Switzerland
Melzer, K., Schutz, Y., Boulvain, M., & Kayser, B. (2009) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2009.49 · Cited by 59
Heavy Physical Work: Cardiovascular Load in Male Construction Workers
Lunde, L.-K., Koch, M., Veiersted, K., Moen, G.-H., Wærsted, M., & Knardahl, S. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13040356 · Cited by 49
“Heart rate recording was carried out with, Actiheart 4 (Camntech, Cambridge, UK), a small chest-worn monitoring device consisting of two clips attached to standard electrocardiogram electrodes (Blue sensor VL-00-S/25 Ambu, Ballerup, Denmark) placed at the apex of the sternum and at the left intercostals at the level o…”
MethodCardiorespiratory fitness and physical activity in Luo, Kamba, and Maasai of rural Kenya
Christensen, D. L., Faurholt‐Jepsen, D., Boit, M. K., Mwaniki, D. L., Kilonzo, B., Tetens, I., Kiplamai, F. K., Cheruiyot, S. C., Friis, H., Borch‐Johnsen, K., et al. (2012) · American Journal of Human Biology · doi:10.1002/ajhb.22303 · Cited by 48
“…the chest on two ECG electrodes (Unomedical A/S, Birkerød, Denmark); a medial electrode placed at the lower part of the sternum, and a lateral electrode placed on the same horizontal level and as laterally as possible without stretching the wire below the major pectoral muscle (Brage et al., 2006).”
Self-citationMeasuring Activity Energy Expenditure: Accuracy of the GT3X+ and Actiheart Monitors
McMinn, D., Acharya, R., Rowe, D. A., Gray, S. R., & Allan, J. L. (2013) · International Journal of Exercise Science · doi:10.70252/qebt3375 · Cited by 48
Brandt, M., Madeleine, P., Samani, A., Ajslev, J. Z. N., Jakobsen, M. D., Sundstrup, E., & Andersen, L. L. (2018) · Journal of Medical Internet Research · doi:10.2196/10272 · Cited by 59
“…monitoring electrodes (Ø: 68 mm; Blue Sensor VL-00-S/25, Ambu A/S, Ballerup, Denmark) were positioned just below the apex of the sternum and laterally under the left pectoralis major muscle [43,44], before connecting to the heart rate monitor (Actiheart, CamNtech Ltd, Cambridge, United Kingdom).”
Takken, T., Stephens, S., Balemans, A. C. J., Tremblay, M. S., Esliger, D., Schneiderman, J. E., Biggar, D., Longmuir, P., Wright, F. V., McCrindle, B. W., et al. (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.196 · Cited by 46
Resting heart rate is a population-level biomarker of cardiorespiratory fitness: The Fenland Study
Gonzales, T. I., Jeon, J. Y., Lindsay, T., Westgate, K., Perez-Pozuelo, I., Hollidge, S., Wijndaele, K., Rennie, K., Forouhi, N., Griffin, S., et al. (2023) · PLOS ONE · doi:10.1371/journal.pone.0285272 · Cited by 44
“Habitual sleeping heart rate was estimated from these data by first deriving a robust daily minimum heart rate as the thirtieth lowest minute-by-minute heart rate reading during each 24-hour period, and then averaging across days [12].”
MethodSelf-citationCombining Accelerometry and HR for Assessing Preschoolers' Physical Activity
Bock, F. D., MENZE, J., Becker, S., Litaker, D. G., Fischer, J. E., & Seidel, I. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e27b5d · Cited by 57
Lunde, L.-K., Koch, M., Knardahl, S., Wærsted, M., Mathiassen, S. E., Forsman, M., Holtermann, A., & Veiersted, K. B. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-1075 · Cited by 55
“Recommended placements will be applied, attaching electrodes at the apex of the sternum and at the left intercostals at the level of the 6 and 7 costae [69].”
MethodSchrack, J. A., Gresham, G. K., & Wanigatunga, A. A. (2017) · Molecular Case Studies · doi:10.1101/mcs.a001933 · Cited by 48
“These devices are well validated in the scientific literature (Freedson et al. 1998; Brage et al. 2006; Sasaki et al. 2011; John et al. 2013; Welch et al. 2013; Lyden et al. 2014), several have FDA medical device approval, and all provide access to the raw data as either activity counts or gravitational acceleration u…”
BackgroundAccumulation of saturated intramyocellular lipid is associated with insulin resistance
Savage, D. B., Watson, L. P. E., Carr, K., Adams, C., Brage, S., Chatterjee, K., Hodson, L., Boesch, C., Kemp, G. J., & Sleigh, A. (2019) · Journal of Lipid Research · doi:10.1194/jlr.m091942 · Cited by 49
“For the control participants, a standard incremental protocol was performed (26), whereas the athletes undertook a protocol that began with a 10 min warm-up period at each participant’s preferred warm-up running speed, after which the test was initiated at 9 km/h and increased steadily (0.”
MethodSelf-citationState-related differences in heart rate variability in bipolar disorder
Faurholt‐Jepsen, M., Brage, S., Kessing, L. V., & Munkholm, K. (2016) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2016.10.005 · Cited by 40
“The sensor was mounted on the thorax at the apex of the sternum and lateral to the left in a horizontal line using two ECG electrodes (Unomedical, Mona Vale, Australia) (Brage et al., 2006) during as many different affective states as possible for each patient.”
MethodSelf-citationRegistration for Exponential Family Functional Data
Wrobel, J., Zipunnikov, V., Schrack, J. A., & Goldsmith, J. (2018) · Biometrics · doi:10.1111/biom.12963 · Cited by 51
Faurholt‐Jepsen, M., Brage, S., Vinberg, M., & Kessing, L. V. (2016) · Psychiatry Research · doi:10.1016/j.psychres.2016.01.047 · Cited by 47
“…and manic symptoms using clinical ratings and the heart rate and movement sensor was mounted on the thorax at the apex of the sternum and lateral to the left in a horizontal line using two ECG electrodes (Unomedical, Mona Vale, Australia) (Brage et al., 2006) during different affective states.”
MethodSelf-citationCoenen, P., Korshøj, M., Hallman, D., Huysmans, M. A., van der Beek, A. J., Straker, L. M., & Holtermann, A. (2018) · Physiology & Behavior · doi:10.1016/j.physbeh.2018.01.011 · Cited by 42
“After preparation of the skin (i.e., cleaning with ethanol solution), the ECG electrodes were placed on the chest at one of the two standardized positions (Brage et al., 2006).”
MethodThe effect on energy expenditure of walking on gradients or carrying burdens
Kramer, P. A. (2010) · American Journal of Human Biology · doi:10.1002/ajhb.21027 · Cited by 46
“…have examined the energy expenditure of gradient walking but did not develop predictive equations (Ainslie et al., 2002a; Ainslie et al., 2002b; Brage et al., 2006; Butts et al., 1995; Campbell et al., 2002; Christie and Scott, 2005; Fruin and Rankin, 2004; Klimek and Klimek, 2007; McIntosh et…”
BackgroundHjorth, M. F., Kloster, S., Girma, T., Faurholt‐Jepsen, D., Andersen, G. S., Kæstel, P., Brage, S., & Friis, H. (2012) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-12-154 · Cited by 39
“The monitor was placed on the left side of the trunk, at the level of the third intercostal space, on two ECG electrodes (Unilect TM Diagnostic ECG Ref 0668M, Redditch, UK); one electrode on the sternum and one as lateral as possible without stretching the wire [13].”
MethodSelf-citationAtkin, A. J., Corder, K. L., Goodyer, I. M., Bamber, D. J., Ekelund, U., Brage, S., Dunn, V. J., & van Sluijs, E. M. F. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0180-x · Cited by 43
“Physical activity and sedentary time were assessed objectively using combined heart rate and movement sensing (Actiheart, CamNtech Ltd, Papworth, UK) [26] Following an eight-minute step test for individual calibration of the heart rate–activity intensity relationship [27], the device was set-up to collect data in 30-s…”
MethodSelf-citationEspaña‐Romero, V., Golubić, R., Martin, K. R., Hardy, R., Ekelund, U., Kuh, D. J., Wareham, N. J., Cooper, R., Brage, S., & teams, O. B. O. T. N. S. A. D. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087085 · Cited by 41
“Objective PA was assessed using a combined HR and movement sensor (Actiheart, CamNtech Ltd, Cambridge, UK) attached to standard electrocardiogram electrodes (Red Dot 2570: 3M, Loughborough, United Kingdom) at the level just below the apex of the sternum [21,22].”
MethodSelf-citationCosta, J. D., Seixas, J. M., & de Sá, A. M. F. L. M. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.09.004 · Cited by 32
Is Surface ECG a Useful Surrogate for Subcutaneous ECG?
Bellardine, C. L., Stromberg, K. D., van Balen, G. P., Ghanem, R. N., Breedveld, R. W., & Tieleman, R. G. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02616.x · Cited by 31
Mackintosh, K. A., Standage, M., Staiano, A. E., Lester, L., & McNarry, M. A. (2016) · Games for Health Journal · doi:10.1089/g4h.2016.0015 · Cited by 40
“The Actiheart, which was calibrated for each participant’s age, body mass, and stature, has been reported to provide valid and reliable measures of free living physical activity levels.(33,34) Immediately after each exergaming condition, participants were asked to complete a series of questionnaires to assess the psyc…”
MethodNastasi, A. J., Ahuja, A., Zipunnikov, V., Simonsick, E. M., Ferrucci, L., & Schrack, J. A. (2017) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000830 · Cited by 32
“The devicewas placed horizontally on the chest at the third intercostal spacewith two standard electrocardiogram electrodes, a valid and reliable placement for measuring free-living PA.17,18 Heart rate and activity counts were measured in 1-min epochs for up to 7 days, after which time the monitors were returned by ex…”
MethodThe Actiheart in Adolescents: A Doubly Labelled Water Validation
Campbell, N., Prapavessis, H., Gray, C. E., McGowan, E. L., Rush, E. C., & Maddison, R. (2012) · Pediatric Exercise Science · doi:10.1123/pes.24.4.589 · Cited by 34
SEDLACEK, S. M., Playdon, M. C., Wolfe, P., McGinley, J. N., Wisthoff, M. R., Daeninck, E. A., Jiang, W., Zhu, Z., & Thompson, H. J. (2011) · BMC Cancer · doi:10.1186/1471-2407-11-287 · Cited by 30
“The Actiheart has been assessed as being valid and reliable in predicting energy expenditure with walking and running [93,94].”
MethodValidity of the Polar M430 Activity Monitor in Free-Living Conditions: Validation Study
Henriksen, A., Grimsgaard, S., Horsch, A., Hartvigsen, G., & Hopstock, L. A. (2019) · JMIR Formative Research · doi:10.2196/14438 · Cited by 37
“The Actiheart is extensively used to measure EE, and has been shown by Brage et al to produce valid estimations for EE both in laboratory settings [16] and under free-living conditions [17].”
Christensen, D. L., Espino, D., Infante‐Ramírez, R., Brage, S., Terzic, D., Goetze, J. P., & Kjærgaard, J. (2014) · American Journal of Human Biology · doi:10.1002/ajhb.22607 · Cited by 29
“…the chest on two ECG electrodes (Unomedical A/S, Birker d, Denmark); a medial electrode placed at the lower part of the sternum, and a lateral electrode placed on the same horizontal level and as laterally as possible without stretching the wire below the major pectoral muscle (Brage et al., 2006).”
Self-citationKorshøj, M., Rasmussen, C. L., Sato, T. D. O., Holtermann, A., & Hallman, D. (2021) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.3965 · Cited by 34
“The electrodes were attached to the chest, according to previous recommendations (18).”
MethodWade, J. B., Hayes, R. B., Wade, J. H., Bekenstein, J. W., Williams, K. D., & Bajaj, J. S. (2018) · Geriatrics · doi:10.3390/geriatrics3030035 · Cited by 33
Rocha, J., Paxman, J. R., Dalton, C., Winter, E., & Broom, D. R. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2016-0189 · Cited by 29
“This positioning of the monitor at 228 the level below the apex of the sternum produces clearer heart rate data (Brage et al. 2006).”
BackgroundMetabolic Equivalent in Adolescents, Active Adults and Pregnant Women
Melzer, K., Heydenreich, J., Schütz, Y., Renaud, A., Kayser, B., & Mäder, U. (2016) · Nutrients · doi:10.3390/nu8070438 · Cited by 32
“, Papworth, UK) was clipped onto two standard electrocardiography electrodes (Red Dot Electrode 3560; 3M, Diegem, Belgium) on the left thorax just below the level of the apex of the sternum [20].”
MethodBayer, O., Jarczok, M. N., Fischer, J. E., von Kries, R., & Bock, F. D. (2012) · Public Health Nutrition · doi:10.1017/s1368980012001243 · Cited by 23
“After programming the Actiheart monitor was securely affixed to the children’s substernal thorax((30)) by two sticky electrodes and stayed there until 6d later if not taken off before.”
Heydenreich, J., Schütz, Y., Melzer, K., & Kayser, B. (2019) · Nutrients · doi:10.3390/nu11020458 · Cited by 28
“Paul, USA) on the chest of the participant, according to the manufacturer’s instructions, and worn day and night [46].”
MethodFaurholt‐Jepsen, M., Brage, S., Vinberg, M., Jensen, H. M., Christensen, E. M., Knorr, U., & Kessing, L. V. (2014) · Nordic Journal of Psychiatry · doi:10.3109/08039488.2014.936501 · Cited by 25
Self-citationDoes the Treadmill Support Valid Energetics Estimates of Field Locomotion?
Bidder, O. R., Goulding, C., Toledo, A., van Walsum, T. A., Siebert, U., & Halsey, L. G. (2017) · Integrative and Comparative Biology · doi:10.1093/icb/icx038 · Cited by 24
“This is intended to induce systematic variations both in rate of energy expenditure (measured as rate of oxygen consumption; _ VO2) and in the proxy, to enable a calibration curve to be fitted (Nolet et al. 1992; Bevan et al. 1995; Hawkins et al. 2000; Froget et al. 2001; Green et al. 2001; Brage et al. 2006; Halsey e…”
BackgroundMerkus, S. L., Coenen, P., Forsman, M., Knardahl, S., Veiersted, K. B., & Mathiassen, S. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052751 · Cited by 26
“Standard ECG electrodes (Blue sensor VL-00S/25 Ambu, Ballerup, Denmark) were attached at the apex of the sternum and on the left intercostal muscles at the level of the 6th and 7th costae [42].”
MethodDifferent methods for monitoring intensity during water-based aerobic exercises
Raffaelli, C., Galvani, C., Lanza, M., & Zamparo, P. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1963-7 · Cited by 28
“…data obtained with: • a heart rate monitor (T31, Polar, Finland); • an activity monitoring system (Actiheart, Cambridge Neurotechnology, UK), which was applied, after skin preparation, with ECG electrodes on the left side of the chest and in the lower position (as indicated by Brage et al. 2006).”
BackgroundMethodSimple fixed-effects inference for complex functional models
Park, S., Staicu, A., Xiao, L., & Crainiceanu, C. M. (2017) · Biostatistics · doi:10.1093/biostatistics/kxx026 · Cited by 20
“Participants in the study wore the Actiheart portable physical activity monitor (Brage et al. 2006) 24 hours a day for a number of days. Activity counts were measured in 1-min epochs and each daily activity profile has 1440 minute-by-minute measurements of activity counts. Activity counts are proxies of activity inten…”
MethodInfluentialPhysical activity energy expenditure and cardiometabolic health in three rural Kenyan populations
Lee, J. C., Westgate, K. L., Boit, M. K., Mwaniki, D. L., Kiplamai, F., Friis, H., Tetens, I., Christensen, D. L., & Brage, S. (2018) · American Journal of Human Biology · doi:10.1002/ajhb.23199 · Cited by 20
Self-citationRasmussen, C. L., Palarea‐Albaladejo, J., Korshøj, M., Gupta, N., Nabe‐Nielsen, K., Holtermann, A., & Jørgensen, M. B. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217024 · Cited by 16
“96 [35; 219] 106 [47; 213] 64 [30; 116] 72 [36; 153] 87 [20; 221] +15 min�40%HRR 98 [37; 215] 2 106 [50; 206] 0 64 [32; 115] 0 71 [38; 149] -1 87 [21; 201] 0 +30 min�40%HRR 100 [39; 212] 4 107 [52; 201] 1 65 [33; 112] 1 69 [40; 146] -3 87 [22; 186] 0 +45 min�40%HRR 102 [42; 207] 6 107 [54; 197] 1 65 [34; 112] 1 68 [42…”
MethodRocha, J., Paxman, J., Dalton, C., Winter, E., & Broom, D. (2015) · Appetite · doi:10.1016/j.appet.2015.02.005 · Cited by 16
“Free-living energy expenditure was estimated using an Actiheart (Cambridge Neurotechnology, Cambridge, UK) that was attached to each participant’s chest (lower position described in Brage et al., 2006 ) using electrocardiogram (ECG) electrodes (E4 T815 Telectrode, Surrey, UK).”
Svensson, Å., Renström, F., Bluck, L. J. C., Lissner, L., Franks, P. W., & Larsson, C. L. (2013) · Public Health Nutrition · doi:10.1017/s1368980013003042 · Cited by 20
“our study design and setting differed from the earlier studies((16,17)), we sought to recruit .”
BackgroundResultSelf-citationInfluence of pulsing electromagnetic field therapy on resting blood pressure in aging adults
Rikk, J., Finn, K. J., Liziczai, I., Radak, Z. O., Bori, Z., & Ihász, F. (2013) · Electromagnetic Biology and Medicine · doi:10.3109/15368378.2013.776420 · Cited by 16
“The duration and quality of appropriate physical activity induce direct regulatory effect on the cardiovascular system (Armstrong & Welsman, 2006; Brage et al., 2006; Thompson et al., 2003).”
BackgroundPrepregnancy Body Mass Index and Resting Metabolic Rate during Pregnancy
Melzer, K., Schütz, Y., Soehnchen, N., Girard, V. O., de Tejada, B. M., Pichard, C., Irion, O. P., Boulvain, M., & Kayser, B. (2010) · Annals of Nutrition and Metabolism · doi:10.1159/000322369 · Cited by 20
Hillier-Brown, F. C., Batterham, A. M., Crooks, S., Moore, H. J., & Summerbell, C. (2011) · British Journal Of Nutrition · doi:10.1017/s0007114511004090 · Cited by 18
“A previous study((49)) showed that although cleaner heart rate data might be obtained in the lower position, there is no substantial difference in energy expenditure or count variables produced by monitors positioned at each site.”
Distribution and determinants of maximal physical work capacity of Korean male metal workers
Kang, D., Woo, J.-H., & Shin, Y. C. (2007) · Ergonomics · doi:10.1080/00140130701450153 · Cited by 17
“Further studies should use more valid methods including the ‘flex-HR’ (Livingstone et al. 1992, Leonard 2003), which is the method establishing individual-level calibrations between heart rate and energy expenditure, and combined movement and heart rate monitor devices (Brage et al. 2005, 2006).”
MethodGait Alteration in Individual with Limb Loss: The Role of Inertial Sensors
Demeco, A., Frizziero, A., Nuresi, C., Buccino, G., Pisani, F., Martini, C., Foresti, R., & Costantino, C. (2023) · Sensors · doi:10.3390/s23041880 · Cited by 16
“In this context, technology advancement has led to the development of new multimodal sensors that record both classic inertial data and heartbeat, whih were successfully utilized to monitor the physical activity of healthy subjects [87].”
BackgroundAlterations in energy balance from an exercise intervention with ad libitum food intake
Melzer, K., Renaud, A., Zurbuchen, S., Tschopp, C., Lehmann, J., Malatesta, D., Ruch, N., Schütz, Y., Kayser, B., & Mäder, U. (2016) · Journal of Nutritional Science · doi:10.1017/jns.2015.36 · Cited by 15
“109; CamNtech Ltd) was clipped onto two ECG electrodes (3 M Red Dot Electrode 3560) on the left thorax just below the apex of the sternum((34)).”
MethodCampbell, N., Gray, C. E., Foley, L. S., Maddison, R., & Prapavessis, H. (2015) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2015.05.002 · Cited by 15
Physical Activity Recognition Using a Wearable Accelerometer
Bonomi, A. G. (2010) · Philips Research · doi:10.1007/978-90-481-3258-4_3 · Cited by 17
Miller, C. T., Fraser, S. F., Selig, S., Rice, T., Grima, M. T., Straznicky, N. E., Levinger, I., Lambert, É., van den Hoek, D., & Dixon, J. B. (2016) · Trials · doi:10.1186/s13063-016-1232-5 · Cited by 14
“Participants will be fitted with an Acti-heart® heart rate and activity monitor that will be worn for 7 days as described previously [86, 87].”
Validation of the Actiheart for estimating physical activity related energy expenditure in pregnancy
Melzer, K., Lazzeri, M., Armand, S., Boulvain, M., Schutz, Y., & Kayser, B. (2012) · e-SPEN Journal · doi:10.1016/j.eclnm.2011.12.008 · Cited by 11
Löf, M., Henriksson, H., & Forsum, E. (2013) · Journal of Nutritional Science · doi:10.1017/jns.2013.18 · Cited by 11
“Brage et al.((40)) reported higher noise rates in women than in men when using Actiheart, suggesting that this sex difference is due to signal attenuation caused by more subcutaneous fat in women than in men.”
BackgroundNonnegative decomposition of functional count data
Backenroth, D., Shinohara, R. T., Schrack, J. A., & Goldsmith, J. (2020) · Biometrics · doi:10.1111/biom.13220 · Cited by 9
SWISSPAQ: validation of a new physical activity questionnaire in cardiac rehabilitation patients
Bähler, C., Bjarnason‐Wehrens, B., Schmid, J., & Saner, H. E. (2013) · Swiss Medical Weekly · doi:10.4414/smw.2013.13752 · Cited by 8
Estimating maximal oxygen consumption from heart rate response to submaximal ramped treadmill test
Gonzales, T. I., Westgate, K., Hollidge, S., Lindsay, T., Jeon, J., & Brage, S. (2020) · doi:10.1101/2020.02.18.20024489 · Cited by 7
Self-citationSchmidt‐Andersen, P., Møller, T., Mogensen, P. R., Schmiegelow, K., Larsen, H. B., & Nielsen, M. K. F. (2020) · Pediatric Physical Therapy · doi:10.1097/pep.0000000000000712 · Cited by 8
Heydenreich, J., Schütz, Y., Melzer, K., & Kayser, B. (2019) · Current Issues in Sport Science (CISS) · doi:10.15203/ciss_2019.003 · Cited by 7
“The Actiheart was clipped onto two standard ECG electrodes (3MTM Red DotTM Electrode 2560; 3M Health Care, St. Paul, USA) on the chest of the participant according to manufacturer’s instructions and worn day and night (Brage et al., 2006).”
MethodCampbell, N. (2012) · Scholarship@Western (Western University) · Cited by 9
Wade, J. B., Hart, R. P., Wade, J. H., Bekenstein, J. W., Ham, C., & Bajaj, J. S. (2016) · Healthy Aging Research · doi:10.1097/01.hxr.0000511870.49216.83 · Cited by 5
Cardiovascular Responses to Stress Utilizing Anticipatory Singing Tasks
Jump, O., & Dockray, S. (2020) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000269 · Cited by 5
Marzano‐Felisatti, J. M., Lucca, L. D., Luján, J. F. G., Priego‐Quesada, J. I., & Pino‐Ortega, J. (2024) · Sensors · doi:10.3390/s24030988 · Cited by 4
Son, H. M., Seonwoo, H., Lim, K., Kim, J., & Chung, J.-H. (2010) · Journal of Biosystems Engineering · doi:10.5307/jbe.2010.35.5.357 · Cited by 4
“360 ×× ∴×× (3)”
InfluentialValidation of the SenseWear HR Armband for Measuring Heart Rate and Energy Expenditure
Crawley, M. B. (2008) · EngagedScholarship @ Cleveland State University (Cleveland State University) · Cited by 4
Directly measured aerobic fitness in male Maasai of Tanzania
Christensen, D. L., Jørgensen, S. W., Koch, L. S., Nordsborg, N. B., Sironga, J., Ramaiya, K. L., Larsen, S., Brage, S., Bygbjerg, I. C., Maro, V. P., et al. (2021) · American Journal of Human Biology · doi:10.1002/ajhb.23674 · Cited by 6
Self-citationButler, M. S., & Luebbers, P. E. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-5484-4.ch003 · Cited by 3
Taylor, M. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000494070.82906.d3 · Cited by 3
“If you feel somewhere between Extremely Easy (0) and Extremely Hard (10) then give a number between 0 and 10.”
BackgroundMethods in functional data analysis and functional genomics
Backenroth, D. (2018) · doi:10.7916/d81r82fm · Cited by 3
“, 2014], a sample of elderly healthy subjects wore the Actiheart, a combined heart rate and accelerometer adhesively placed on the chest [Brage et al., 2006].”
BackgroundMethodBonomi, A. (2010) · Research Publications (Maastricht University) · doi:10.26481/dis.20101208abo · Cited by 3
Energy expenditure and intensity of ritual jumping–dancing in male M aasai
Christensen, D. L., Westgate, K. L., Griffiths, L., Sironga, J., Maro, V. P., Helge, J. W., Larsen, S., Bygbjerg, I. C., Ramaiya, K. L., Jensen, J., et al. (2023) · American Journal of Human Biology · doi:10.1002/ajhb.23907 · Cited by 4
“The monitor was applied to the chest on two electro-cardiogram electrodes (Unomedical A/S, Lejre, Denmark); a medial electrode placed at the lower part of the sternum, and a lateral electrode placed on the same horizontal level without stretching the wire below the major pectoral muscle (Brage et al., 2006).”
MethodSelf-citationEnergy Expenditure of Elite Male and Female Professional Tennis Players During Habitual Training
Ellis, D. G., Morton, J. P., Close, G. L., & Donovan, T. F. (2024) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2023-0197 · Cited by 3
Physical Activity and Pregnancy
Moss, S. J., van Oort, A. F., & Schütz, Y. (2016) · Springer eBooks · doi:10.1007/978-1-4939-3402-7_16 · Cited by 3
Metadata
- Authors
- Brage, S., Brage, N., Ekelund, U., Luan, J., Franks, P. W., Froberg, K., & Wareham, N. J.
- Affiliations
- MRC Elsie Widdowson Laboratory (GB)
- University of Southern Denmark (DK)
- Corresponding author
- Brage, Søren
- Venue
- European Journal of Applied Physiology
- Published
- 2005-12-13
- Volume
- 96
- Issue
- 5
- Pages
- 517-524
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2062313928
- Semantic Scholar
- a6f62112feb4574123692230b80f1ac1b231293a
- Cited by
- 127
- References
- 37
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 10 · 2017: 5 · 2016: 17 · 2015: 6 · 2014: 11 · 2013: 9 · 2012: 9
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Funders
- Wellcome Trust
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- Actiheart, wearable activity trackers, energy expenditure estimation, treadmill locomotion, free-living physical activity, ECG signal quality, sex differences, incline walking, running
- MeSH terms
- Adult, Electrocardiography, Electrodes, Energy Metabolism, Exercise Test, Female, Heart Rate, Humans, Locomotion, Male, Movement, Ribs, Sex Factors, Sternum, Reproducibility of Results, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.